Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”900 VA”,”rank”:4,”value”:”900VA”},{“name”:”Mounting”,”normalizedValue”:”Desktop”,”rank”:5,”value”:”Desktop”},{“name”:”Wattage”,”normalizedValue”:”480 W”,”rank”:6,”value”:”480 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V”,”rank”:8,”value”:”110/115/120V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”10 min/2.7 min”,”rank”:9,”value”:”10 min/2.7 min”},{“name”:”Outlet Type”,”normalizedValue”:”(6) Surge; (6) UPS/Surge”,”rank”:10,”value”:”(6) Surge; (6) UPS/Surge”},{“name”:”Number of Outlets”,”normalizedValue”:”12″,”rank”:12,”value”:”12″},{“name”:”Width”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4\””},{“name”:”Depth”,”normalizedValue”:”7 in”,”value”:”7\””},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL or Ethernet”,”value”:”1 line TEL/DSL or Ethernet”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”305″,”value”:”305″},{“name”:”Communications Cable”,”normalizedValue”:”USB interface cable included”,”value”:”USB interface cable included”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”120V”,”value”:”120V (+6%/-12%)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”to +45 degrees Celsius”,”value”:”+5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower; Ultra-compact desktop; Wallmount”,”value”:”Tower; Ultra-compact desktop; Wallmount”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”316″,”value”:”316″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”480″,”value”:”480″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Battery Independent Restart”,”value”:”Battery Independent Restart”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”UPS Certification Details”,”normalizedValue”:”UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS A; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia)”,”value”:”UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS A; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia)”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”2 min 42 sec”,”value”:”2.7 min. (480w)”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”8 hours (10% to 90%)”,”value”:”8 hours (10% to 90%)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Hot-Swap PDU options”,”normalizedValue”:”PDUB15 (2U / 8 5-15R outlets)”,”value”:”PDUB15 (2U / 8 5-15R outlets)”},{“name”:”Transfer Time”,”normalizedValue”:”6 milliseconds typical (10 milliseconds max)”,”value”:”6 milliseconds typical (10 milliseconds max)”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Audible Alarm”,”normalizedValue”:”UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace battery conditions”,”value”:”UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace battery conditions”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 89 and 108 are boosted by 18%”,”value”:”Input voltages between 89 and 108 are boosted by 18%”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 128 and 145 are reduced by 15%”,”value”:”Input voltages between 128 and 145 are reduced by 15%”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”Up to 10,000 ft.”,”value”:”Up to 10,000 ft.”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 90%, non-condensing”,”value”:”0 to 90%, non-condensing”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”105″,”value”:”105″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145″},{“name”:”UPS Certifications”,”normalizedValue”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”120V (±10%)”,”value”:”120V (±10%)”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”4.14 x 7.48 x 12″,”value”:”4.14 x 7.48 x 12″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”41″,”value”:”41″},{“name”:”Battery Replacement Description”,”normalizedValue”:”Replaceable internal batteries (see manual)”,”value”:”Replaceable internal batteries (see manual)”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”10 min”,”value”:”10 min. (240w)”},{“name”:”Green Energy-Saving Features”,”normalizedValue”:”Greater than 95% efficiency – GREEN UPS”,”value”:”Greater than 95% efficiency – GREEN UPS”},{“name”:”Grounding Lug”,”normalizedValue”:”Includes side panel lug”,”value”:”Includes optional side-panel grounding lug”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”>96%”,”value”:”>96%”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC51″,”value”:”RBC51″},{“name”:”Primary Form Factor”,”normalizedValue”:”Desktop”,”value”:”Desktop”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”LED Indicators”,”normalizedValue”:”2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions”,”value”:”2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions”},{“name”:”Switches”,”normalizedValue”:”Power off/on switch”,”value”:”Power off/on switch”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”UPS Applications”,”normalizedValue”:”Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality”,”value”:”Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality”},{“name”:”Grounding Details”,”normalizedValue”:”Includes side panel lug, Includes grounding lug”,”value”:”Includes optional side-panel grounding lug”},{“name”:”Package Includes”,”normalizedValue”:”AVR900U 900VA 480W 120V Line-Interactive UPS with 12 Outlets;USB cable;Owner’s manual”,”value”:”AVR900U 900VA 480W 120V Line-Interactive UPS with 12 Outlets;USB cable;Owner’s manual”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”480″,”value”:”480″},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Product Certifications”,”normalizedValue”:”RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778″,”value”:”RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(12) 5-15R”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Housing Material”,”normalizedValue”:”ABS”,”value”:”ABS”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.