Description
[{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:1,”value”:”Line-Interactive”},{“name”:”Item”,”normalizedValue”:”UPS,SmartPro,Sine Wave,1kVA,800W,USB,1U”,”value”:”UPS,SmartPro,Sine Wave,1kVA,800W,USB,1U”},{“name”:”Height”,”normalizedValue”:”1.7 in”,”value”:”1.7\””},{“”name””:””Input Current””,””normalizedValue””:””9 A””,””value””:””9A””},{“”name””:””Transfer Time””,””normalizedValue””:””5 milliseconds AC to DC, 1 millisecond DC to AC””,””value””:””5 milliseconds AC to DC, 1 millisecond DC to AC””},{“”name””:””Depth””,””normalizedValue””:””16.8 in””,””value””:””16.8\””””},{“”name””:””Input Voltage””,””normalizedValue””:””120 V AC””,””value””:””120 V AC””},{“”name””:””Cord Length””,””normalizedValue””:””10 ft””,””value””:””10 ft””},{“”name””:””Output Voltage””,””normalizedValue””:””120 V AC””,””value””:””120 V AC””},{“”name””:””Width””,””normalizedValue””:””17-1/2 in””,””value””:””17.5\””””},{“”name””:””Battery Type””,””normalizedValue””:””Valve Regulated Lead Acid””,””value””:””Valve Regulated Lead Acid (VRLA)””},{“”name””:””Voltage Regulation Description””,””normalizedValue””:””Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147″”,””value””:””Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147″”},{“”name””:””Operating Temperature Range””,””normalizedValue””:””+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius””,””value””:””+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius””},{“”name””:””Audible Noise””,””normalizedValue””:””45 dBA maximum, front side 1m””,””value””:””45 dBA maximum, front side 1m””},{“”name””:””High Availability UPS Features””,””normalizedValue””:””Hot swappable batteries””,””value””:””Hot swappable batteries””},{“”name””:””UPS Dataline Suppression””,””normalizedValue””:””1 line TEL/DSL or Ethernet””,””value””:””1 line TEL/DSL or Ethernet””},{“”name””:””UPS Input Connection Type””,””normalizedValue””:””5-15P””,””value””:””5-15P””},{“”name””:””PowerAlert Software””,””normalizedValue””:””For local monitoring via the UPS™s built-in USB or DB9 ports, download PowerAlert Local software at http://www.tripplite.com/poweralert””,””value””:””For local monitoring via the UPS™s built-in USB or DB9 ports, download PowerAlert Local software at http://www.tripplite.com/poweralert””},{“”name””:””Primary UPS Depth (mm)””,””normalizedValue””:””425″”,””value””:””425″”},{“”name””:””Battery Recharge Rate (Included Batteries)””,””normalizedValue””:””Less than 4.5 hours from 10% to 90%””,””value””:””Less than 4.5 hours from 10% to 90%””},{“”name””:””Primary UPS Height (mm)””,””normalizedValue””:””44″”,””value””:””44″”},{“”name””:””AC Mode Efficiency Rating (100% Load)””,””normalizedValue””:””0.99″”,””value””:””0.99″”},{“”name””:””UPS AC Suppression Joule Rating””,””normalizedValue””:””450″”,””value””:””450″”},{“”name””:””Nominal Input Voltage(s) Supported””,””normalizedValue””:””120 V AC””,””value””:””120V AC””},{“”name””:””WatchDog Compatibility””,””normalizedValue””:””Supports Watchdog application, OS and hard-reboot restart options for remote applications””,””value””:””Supports Watchdog application, OS and hard-reboot restart options for remote applications””},{“”name””:””Communications Cable””,””normalizedValue””:””USB and DB9 cabling included””,””value””:””USB and DB9 cabling included””},{“”name””:””Switches””,””normalizedValue””:””2 Switches control off/on power status and alarm-cancel/self-test operation””,””value””:””2 Switches control off/on power status and alarm-cancel/self-test operation””},{“”name””:””UPS Certification Details””,””normalizedValue””:””UL 1778: 2014 R8.15 (5TH EDITION), CAN/CSA-C22.2 NO. 107.3-14″”,””value””:””UL 1778: 2014 R8.15 (5TH EDITION), CAN/CSA-C22.2 NO. 107.3-14″”},{“”name””:””Internal UPS Replacement Battery Cartridge””,””normalizedValue””:””RBC69-1U””,””value””:””RBC69-1U””},{“”name””:””DC System Voltage (VDC)””,””normalizedValue””:””24″”,””value””:””24″”},{“”name””:””Load Management Receptacles””,””normalizedValue””:””Two switchable single-outlet 5-15R load banks””,””value””:””Two switchable single-outlet 5-15R load banks””},{“”name””:””Output Receptacles””,””normalizedValue””:””5-15R””,””value””:””(6) 5-15R””},{“”name””:””Output AC Waveform (Battery Mode)””,””normalizedValue””:””Pure Sine wave””,””value””:””Pure Sine wave””},{“”name””:””Installation Form Factors Supported with Optional Accessories””,””normalizedValue””:””4 post rackmount full-depth ( 4POSTRAILKIT1U ), 4 post rackmount short-depth ( 4POSTRAILKITWM )””,””value””:””4 post rackmount full-depth ( 4POSTRAILKIT1U ), 4 post rackmount short-depth ( 4POSTRAILKITWM )””},{“”name””:””LED Indicators””,””normalizedValue””:””5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status””,””value””:””5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status””},{“”name””:””Input Phase””,””normalizedValue””:””Single-Phase””,””value””:””Single-Phase””},{“”name””:””AC Mode BTU / Hr. (Full Load)””,””normalizedValue””:””39″”,””value””:””39″”},{“”name””:””Rack Height””,””normalizedValue””:””1 U””,””value””:””1U””},{“”name””:””Overvoltage Correction””,””normalizedValue””:””Input voltages between 128 and 147 are reduced by 12%””,””value””:””Input voltages between 128 and 147 are reduced by 12%””},{“”name””:””Network Management Cards””,””normalizedValue””:””WEBCARDLX, SNMPWEBCARD, TLNETCARD””,””value””:””SNMPWEBCARD , TLNETCARD , WEBCARDLX””},{“”name””:””Power Factor””,””normalizedValue””:””0.8″”,””value””:””0.8″”},{“”name””:””Included Mounting Accessory Description””,””normalizedValue””:””Included mounting brackets provide front-rail installation in 2 or 4 post racks, For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U \u0026 4POSTRAILKITWM””,””value””:””Included mounting brackets provide front-rail installation in 2 or 4 post racks, For additional stability in 4 post racks, consider optional 4 post mounting accessories 4POSTRAILKIT1U \u0026 4POSTRAILKITWM””},{“”name””:””Nominal Output Voltage(s) Supported””,””normalizedValue””:””110 V, 115 V, 120 V””,””value””:””110V, 115V, 120V””},{“”name””:””High Voltage Transfer to Battery Power (Setpoint)””,””normalizedValue””:””147″”,””value””:””147″”},{“”name””:””Half Load Runtime (min.)””,””normalizedValue””:””14 min””,””value””:””14 min. (400w)””},{“”name””:””Communications Interface””,””normalizedValue””:””USB, DB9 Serial, EPO (emergency power off), Slot for SNMP/Web interface””,””value””:””USB, DB9 Serial, EPO (emergency power off), Slot for SNMP/Web interface””},{“”name””:””Nominal Voltage Details””,””normalizedValue””:””120v nominal output in battery mode””,””value””:””120v nominal output in battery mode””},{“”name””:””Output kVA Capacity (kVA)””,””normalizedValue””:””1″”,””value””:””1″”},{“”name””:””AC Suppression Response Time””,””normalizedValue””:””Instantaneous””,””value””:””Instantaneous””},{“”name””:””Alarm Cancel Operation””,””normalizedValue””:””Power-fail alarm can be silenced using alarm-cancel switch, once silenced, alarm will re-sound to indicate low-battery status””,””value””:””Power-fail alarm can be silenced using alarm-cancel switch, once silenced, alarm will re-sound to indicate low-battery status””},{“”name””:””Storage Temperature Range””,””normalizedValue””:””+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius””,””value””:””+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius””},{“”name””:””Battery Access””,””normalizedValue””:””Front panel battery access door””,””value””:””Front panel battery access door””},{“”name””:””Grounding Lug””,””normalizedValue””:””Back panel grounding lug””,””value””:””Back panel grounding lug””},{“”name””:””UPS Power Module Dimensions (hwd, in.)””,””normalizedValue””:””1.75 x 17.5 x 16.75″”,””value””:””1.75 x 17.5 x 16.75″”},{“”name””:””Low Voltage Transfer to Battery Power (Setpoint)””,””normalizedValue””:””83″”,””value””:””83″”},{“”name””:””UPS Housing Material””,””normalizedValue””:””Steel””,””value””:””Steel””},{“”name””:””Output Watt Capacity (Watts)””,””normalizedValue””:””800″”,””value””:””800″”},{“”name””:””Rated input current (Maximum Load)””,””normalizedValue””:””9.0A””,””value””:””9.0A””},{“”name””:””Relative Humidity””,””normalizedValue””:””0 to 95%, non-condensing””,””value””:””0 to 95%, non-condensing””},{“”name””:””Input Circuit Breakers””,””normalizedValue””:””15A””,””value””:””15A””},{“”name””:””EMI / RFI AC Noise Suppression””,””normalizedValue””:””Yes””,””value””:””Yes””},{“”name””:””Installation Form Factors Supported with Included Accessories””,””normalizedValue””:””4 post 19 inch rackmount, 2 post 19 inch rackmount””,””value””:””4 post 19 inch rackmount, 2 post 19 inch rackmount””},{“”name””:””Expandable Runtime””,””normalizedValue””:””No””,””value””:””No””},{“”name””:””Audible Alarm””,””normalizedValue””:””Audible alarm indicates power-failure, overload and low-battery conditions””,””value””:””Audible alarm indicates power-failure, overload and low-battery conditions””},{“”name””:””Cooling Method””,””normalizedValue””:””Fan””,””value””:””Fan””},{“”name””:””UPS Certifications””,””normalizedValue””:””Meets FCC Part 15 Category A (EMI), TAA Compliant, Tested to CSA (Canada), Tested to NOM (Mexico), Tested to UL1778 (USA)””,””value””:””Meets FCC Part 15 Category A (EMI), TAA Compliant, Tested to CSA (Canada), Tested to NOM (Mexico), Tested to UL1778 (USA)””},{“”name””:””Recommended Electrical Service””,””normalizedValue””:””15A 120V””,””value””:””15A 120V””},{“”name””:””Output AC Waveform (AC Mode)””,””normalizedValue””:””Pure Sine wave””,””value””:””Pure Sine wave””},{“”name””:””Minimum Required Rack Depth (inches)””,””normalizedValue””:””19.75″”,””value””:””19.75″”},{“”name””:””UPS Input Cord Length (ft.)””,””normalizedValue””:””10″”,””value””:””10″”},{“”name””:””Network Monitoring Port Description””,””normalizedValue””:””Supports detailed monitoring of UPS and site power conditions””,””value””:””Supports detailed monitoring of UPS and site power conditions””},{“”name””:””Output Voltage Regulation (Battery Mode)””,””normalizedValue””:””+/- 5%””,””value””:””+/- 5%””},{“”name””:””Cold Start (Startup in Battery Mode During a Power Failure)””,””normalizedValue””:””Cold-start operation supported””,””value””:””Cold-start operation supported””},{“”name””:””Output Volt Amp Capacity (VA)””,””normalizedValue””:””1,000″”,””value””:””1000″”},{“”name””:””Output Voltage Regulation (Line Mode)””,””normalizedValue””:””-21%, +8%””,””value””:””-21%, +8%””},{“”name””:””Frequency Compatibility””,””normalizedValue””:””60 Hz””,””value””:””60 Hz””},{“”name””:””Primary Form Factor””,””normalizedValue””:””Rackmount””,””value””:””Rackmount””},{“”name””:””Individually Controllable Load Banks””,””normalizedValue””:””Yes””,””value””:””Yes””},{“”name””:””Full Load Runtime (min.)””,””normalizedValue””:””4 min””,””value””:””4 min. (800w)””},{“”name””:””Primary UPS Width (mm)””,””normalizedValue””:””445″”,””value””:””445″”},{“”name””:””Undervoltage Correction””,””normalizedValue””:””Input voltages between 83 and 107 are boosted by 14%””,””value””:””Input voltages between 83 and 107 are boosted by 14%””},{“”name””:””Battery Replacement Description””,””normalizedValue””:””Hot-swappable, user replaceable batteries””,””value””:””Hot-swappable, user replaceable batteries””},{“”name””:””Package Contents””,””normalizedValue””:””SmartPro SM1000RM1UTAA 1000VA Tower/Rack Mountable UPS, Mounting hardware, Cabling for USB \u0026 DB9 Monitoring and EPO Switching, Instruction Manual””,””value””:””SmartPro SM1000RM1UTAA 1000VA Tower/Rack Mountable UPS, Mounting hardware, Cabling for USB \u0026 DB9 Monitoring and EPO Switching, Instruction Manual””},{“”name””:””Backup/Run Time (Full Load)””,””normalizedValue””:””4 Minute””,””value””:””4 Minute””},{“”name””:””USB””,””normalizedValue””:””Yes””,””value””:””Yes””},{“”name””:””Waveform Type””,””normalizedValue””:””Sine Wave””,””value””:””Sine Wave””},{“”name””:””Surge Energy Rating””,””normalizedValue””:””450 J””,””value””:””450 J””},{“”name””:””Alarm””,””normalizedValue””:””Low Battery, Overload, Power Failure””,””value””:””Low Battery, Overload, Power Failure””},{“”name””:””Battery Management””,””normalizedValue””:””user replaceable””,””value””:””User replaceable””},{“”name””:””Plug/Connector Type””,””normalizedValue””:””NEMA 5-15P””,””value””:””NEMA 5-15P””},{“”name””:””Receptacle Detail””,””normalizedValue””:””6 x NEMA 5-15R””,””value””:””6 x NEMA 5-15R””},{“”name””:””Form Factor””,””normalizedValue””:””Tower, Rack””,””value””:””Rack/Tower””},{“”name””:””Product Type””,””normalizedValue””:””Line-interactive UPS””,””value””:””Line-interactive UPS””},{“”name””:””Backup/Run Time (Half Load)””,””normalizedValue””:””14 min””,””value””:””14 Minute””},{“”name””:””Product Name””,””normalizedValue””:””SmartPro SM1000RM1UTAA 1000VA Tower/Rack Mountable UPS””,””value””:””SmartPro SM1000RM1UTAA 1000VA Tower/Rack Mountable UPS””},{“”name””:””Software Included””,””normalizedValue””:””PowerAlert Monitoring””,””value””:””PowerAlert Monitoring””},{“”name””:””TAA Compliant””,””normalizedValue””:””Yes””,””value””:””Yes””},{“”name””:””Load Capacity””,””normalizedValue””:””1000 VA/800 W””,””value””:””1000 VA/800 W””},{“”name””:””Hot Swappable””,””normalizedValue””:””Yes””,””value””:””Yes””},{“”name””:””Status Indicators””,””normalizedValue””:””Line power status, Battery power status, Overload status, Voltage regulation status, Battery low/replace status””,””value””:””Line power status, Battery power status, Overload status, Voltage regulation status, Battery low/replace status””},{“”name””:””Emergency Power OFF””,””normalizedValue””:””Yes””,””value””:””Yes””},{“”name””:””Protection Type””,””normalizedValue””:””Brownout, EMI, RFI, Surge, Black Out, Over Voltage, Under Voltage””,””value””:””Over Voltage, Black Out, Under Voltage, Surge, EMI / RFI, Brownout””},{“”name””:””Serial Port””,””normalizedValue””:””Yes””,””value””:””Yes””},{“”name””:””Maximum Operating Temperature””,””normalizedValue””:””104°F””,””value””:””104°F (40°C)””},{“”name””:””Certifications \u0026 Standards””,””normalizedValue””:””TAA Compliant, UL1778 (USA), CSA (Canada), NOM (Mexico), Meets FCC Part 15 Category A (EMI)””,””value””:””TAA Compliant, UL1778 (USA), CSA (Canada), NOM (Mexico), Meets FCC Part 15 Category A (EMI)””},{“”name””:””Product Line””,””normalizedValue””:””SmartPro””,””value””:””SmartPro””},{“”name””:””Output Capacity (VA)””,””normalizedValue””:””1,000″”,””value””:””1000″”},{“”name””:””Product Compliance””,””normalizedValue””:””FCC Part 15 Class A (USA), Trade Agreements Act (TAA)””,””value””:””FCC Part 15 Class A (USA), Trade Agreements Act (TAA)””},{“”name””:””Output Capacity (Watts)””,””normalizedValue””:””800″”,””value””:””800″”},{“”name””:””UPS Applications””,””normalizedValue””:””Small Network, Large Network, High-End Desktop””,””value””:””Large Network, High-End Desktop/Small Network””},{“”name””:””Package Includes””,””normalizedValue””:””SM1000RM1UTAA SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS,USB cable,DB9 cable,EPO cable,Mounting hardware,Owner’s manual””,””value””:””SM1000RM1UTAA SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS,USB cable,DB9 cable,EPO cable,Mounting hardware,Owner’s manual””},{“”name””:””Runtime Half Load (min.)””,””normalizedValue””:””14 min””,””value””:””14 min. (400W)””},{“”name””:””Runtime Full Load (min.)””,””normalizedValue””:””4 min””,””value””:””4 min. (800W)””},{“”name””:””Grounding Details””,””normalizedValue””:””Back panel grounding lug””,””value””:””Back panel grounding lug””},{“”name””:””Product Certifications””,””normalizedValue””:””CSA (Canada), NOM (Mexico), UL 1778″”,””value””:””CSA (Canada), NOM (Mexico), UL 1778″”},{“”name””:””Country of Origin (subject to change)””,””normalizedValue””:””Taiwan, Province of China””,””value””:””Taiwan, Province of China””},{“”name””:””Package Quantity””,””normalizedValue””:””1″”,””value””:””1″”}]”

Reviews
There are no reviews yet.