Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Standby”,”rank”:3,”value”:”Standby”},{“name”:”Power Rating”,”normalizedValue”:”850 VA”,”rank”:4,”value”:”850VA”},{“name”:”Mounting”,”normalizedValue”:”Wall, Desktop”,”rank”:5,”value”:”Desktop/Wall”},{“name”:”Wattage”,”normalizedValue”:”425 W”,”rank”:6,”value”:”425 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V”,”rank”:8,”value”:”110/115/120V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”9 min/2.3 min”,”rank”:9,”value”:”9 min/2.3 min”},{“name”:”Outlet Type”,”normalizedValue”:”(6) Surge; (6) UPS/Surge”,”rank”:10,”value”:”(6) Surge; (6) UPS/Surge”},{“name”:”Number of Outlets”,”normalizedValue”:”12″,”rank”:12,”value”:”12″},{“name”:”Height”,”normalizedValue”:”3-1/2 in”,”value”:”3.5\””},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Plastic”,”value”:”Plastic”},{“name”:”Width”,”normalizedValue”:”14.92 in”,”value”:”14.92 in”},{“name”:”Depth”,”normalizedValue”:”14.92 in”,”value”:”14.92\””},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower; Ultra-compact desktop; Wallmount”,”value”:”Tower; Ultra-compact desktop; Wallmount”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”120V (±10%)”,”value”:”120V (±10%)”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”310″,”value”:”310″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”2 min 18 sec”,”value”:”2.3 min. (425w)”},{“name”:”Audible Alarm”,”normalizedValue”:”UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions”,”value”:”UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”Up to 10,000 ft.”,”value”:”Up to 10,000 ft.”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”95″,”value”:”95″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”9 min”,”value”:”9 min. (212.5w)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”to +45 degrees Celsius”,”value”:”+5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”120V”,”value”:”120V (±20%)”},{“name”:”UPS Certification Details”,”normalizedValue”:”UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS B; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia)”,”value”:”UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS B; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia)”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”\u003e98%”,”value”:”\u003e98%”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Battery Independent Restart”,”value”:”Battery Independent Restart”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”Switches”,”normalizedValue”:”Switch controls power off/on status and ECO mode off/on status”,”value”:”Switch controls power off/on status and ECO mode off/on status”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL or Ethernet”,”value”:”1 line TEL/DSL or Ethernet”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.35 x 5.12 x 12.2″,”value”:”3.35 x 5.12 x 12.2″},{“name”:”UPS Certifications”,”normalizedValue”:”ENERGY STAR Qualified; Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”ENERGY STAR Qualified; Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”850″,”value”:”850″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”8.3″,”value”:”8.3″},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”425″,”value”:”425″},{“name”:”Communications Cable”,”normalizedValue”:”USB interface cable included”,”value”:”USB interface cable included”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”8 hours from 10% to 90%”,”value”:”8 hours from 10% to 90%”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Replaceable internal batteries (see manual)”,”value”:”Replaceable internal batteries (see manual)”},{“name”:”Transfer Time”,”normalizedValue”:”6 milliseconds typical (10 milliseconds max)”,”value”:”6 milliseconds typical (10 milliseconds max)”},{“name”:”Load Management Receptacles”,”normalizedValue”:”The ECO Energy-Saving option will automatically POWER OFF four designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 21 watts or more (see manual)”,”value”:”The ECO Energy-Saving option will automatically POWER OFF four designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 21 watts or more (see manual)”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC51″,”value”:”RBC51″},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Touchscreen LCD reports operating mode, input/output voltage, input/output frequency and load capacity”,”value”:”Touchscreen LCD reports operating mode, input/output voltage, input/output frequency and load capacity”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Primary Form Factor”,”normalizedValue”:”Desktop”,”value”:”Desktop”},{“name”:”Green Energy-Saving Features”,”normalizedValue”:”Greater than 95% efficiency – GREEN UPS; Power saving auto-shutoff ECO outlets”,”value”:”Greater than 95% efficiency – GREEN UPS; Power saving auto-shutoff ECO outlets”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 90%, non-condensing”,”value”:”0 to 90%, non-condensing”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”316″,”value”:”316″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”85″,”value”:”85″},{“name”:”Product Certifications”,”normalizedValue”:”RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778″,”value”:”RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”UPS Applications”,”normalizedValue”:”Computer/Peripherals; Retail/Point of Sale; Hospitality”,”value”:”Computer/Peripherals; Retail/Point of Sale; Hospitality”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”850″,”value”:”850″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”425″,”value”:”425″},{“name”:”Package Includes”,”normalizedValue”:”ECO850LCD 850VA 425W 120V Standby ECO UPS with 12 Outlets;USB cable;Owner’s manual”,”value”:”ECO850LCD 850VA 425W 120V Standby ECO UPS with 12 Outlets;USB cable;Owner’s manual”},{“name”:”Product Compliance”,”normalizedValue”:”ENERGY STAR Qualified; FCC Part 15 Class B (USA)”,”value”:”ENERGY STAR Qualified; FCC Part 15 Class B (USA)”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(12) 5-15R”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.