UPS System, 3kVA, Line Interactive, Out: 100/110/120/125V AC In: 120V AC

$1750,99

UPS System, Line Interactive, Power Rating 3 kVA, Wattage 2.88 kW, Input Voltage 120V AC, Output Voltage 120V AC, Backup Time (Half/Full Load) 10 min/3 min, Mounting Rack, Outlet Type UPS/Surge, Number of Outlets 9, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15/20R, L5-30R, NEMA Plug Configuration L5-30P, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 5 msec, Width 18 in, Depth 19 in, Height 4 in, Cord Length 10 ft, Display Type LCD

9999 in stock

SKU: GRG6075501 Category:

Description

[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”3 kVA”,”rank”:2,”value”:”3.0 kVA”},{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”3 kVA”,”rank”:4,”value”:”3kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”3 kW”,”rank”:6,”value”:”3 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/120/125V AC”,”rank”:8,”value”:”100/110/120/125V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”9 min/3 min”,”rank”:9,”value”:”9 min/3 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”9″,”rank”:12,”value”:”9″},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Width”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Ports”,”normalizedValue”:”EPO, RS232, Slot for SNMPWEBCARD, USB”,”value”:”EPO, RS232, Slot for SNMPWEBCARD, USB”},{“name”:”Special Features”,”normalizedValue”:”Cold Start Operation Supported, Hot Swappable Batteries, Individually Controllable Load Banks, Schedulable Daily Hours of Economy Mode Operation”,”value”:”Cold Start Operation Supported, Hot Swappable Batteries, Individually Controllable Load Banks, Schedulable Daily Hours of Economy Mode Operation”},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Footnotes”,”normalizedValue”:”Slot for SNMPWEBCARD”,”value”:”Slot for SNMPWEBCARD”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L5-30R, 5-15/20R”,”value”:”(8) 5-15/20R; (1) L5-30R”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), CSA (Canada), FCC Part 15 Class B (USA), RoHS, UL1778″,”value”:”CE (Europe), CSA (Canada), FCC Part 15 Class B (USA), RoHS, UL1778″},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Depth”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Input Current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Transfer Time”,”normalizedValue”:”5 msec”,”value”:”5 msec”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Includes”,”normalizedValue”:”(4) Post Rack Mount Installation Kits, PowerAlert Software with USB, Serial and EPO Cables”,”value”:”(4) Post Rack Mount Installation Kits, PowerAlert Software with USB, Serial and EPO Cables”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Overall Height”,”normalizedValue”:”3.4 in”,”value”:”3.4 in”},{“name”:”Overall Width”,”normalizedValue”:”17.2 in”,”value”:”17.2 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”3000 VA/2880 W”,”value”:”3000 VA/2880 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-30P Plug”,”value”:”NEMA 5-30P Plug”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”Two 20A output breakers protect 4 5-15/20R outlets each”,”value”:”Two 20A output breakers protect 4 5-15/20R outlets each”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”10 min”,”value”:”10 min. (1440w)”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.5 x 17.5 x 19″,”value”:”3.50 x 17.50 x 19.00″},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”24.5″,”value”:”24.5″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”24 A”,”value”:”24A”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC58-2U”,”value”:”RBC58-2U”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”26″,”value”:”26″},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”3 min”,”value”:”3 min. (2880w)”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+6%, -14%”,”value”:”+6%, -14%”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/-5%”,”value”:”+/-5%”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable single outlet 5-15/20R load banks”,”value”:”Two switchable single outlet 5-15/20R load banks”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, replaceable batteries”,”value”:”Hot-swappable, replaceable batteries”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 5 hours from 10 to 90% (typical, full load discharge)”,”value”:”Less than 5 hours from 10 to 90% (typical, full load discharge)”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX”},{“name”:”Audible Noise”,”normalizedValue”:”45 dBA maximum, front side 1m”,”value”:”45 dBA maximum, front side 1m”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”,”value”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,736″,”value”:”1736″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”30A 120V”,”value”:”30A 120V”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”,”value”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”483″,”value”:”483″},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 127 and 145 are reduced by 12%”,”value”:”Input voltages between 127 and 145 are reduced by 12%”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”2.88″,”value”:”2.88″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”UPS Certifications”,”normalizedValue”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”83″,”value”:”83″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”2,880″,”value”:”2880″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”409″,”value”:”409″},{“name”:”Power Factor”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 108 and 96 are boosted by 12%”,”value”:”Input voltages between 108 and 96 are boosted by 12%”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 83 and 95 are boosted by 24%”,”value”:”Input voltages between 83 and 95 are boosted by 24%”},{“name”:”Switches”,”normalizedValue”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions”,”value”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 and EPO cabling included”,”value”:”USB, DB9 and EPO cabling included”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Load Capacity”,”normalizedValue”:”3000 VA/3000 W”,”value”:”3000 VA/3000 W”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Form Factor”,”normalizedValue”:”Rack-mountable”,”value”:”Rack-mountable”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”5 hr”,”value”:”5 Hour”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro SMART3000RMXL2U 3000VA Rack-mountable UPS, UPS power module with internal batteries, PowerAlert Software CD with USB, DB9 and EPO cabling, 4 x post rackmount installation accessories, Owner’s manual with warranty information”,”value”:”SmartPro SMART3000RMXL2U 3000VA Rack-mountable UPS, UPS power module with internal batteries, PowerAlert Software CD with USB, DB9 and EPO cabling, 4 x post rackmount installation accessories, Owner’s manual with warranty information”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”80V-151V; adjustable to 70-153V”,”value”:”80V-151V; adjustable to 70-153V”},{“name”:”Package Includes”,”normalizedValue”:”3000VA 3000W 120V Line-Interactive UPS;USB cable;DB9 cable;Rack-mounting hardware;Tower support stands;Safety instructions;Quick Start Guide”,”value”:”3000VA 3000W 120V Line-Interactive UPS;USB cable;DB9 cable;Rack-mounting hardware;Tower support stands;Safety instructions;Quick Start Guide”},{“name”:”Grounding Details”,”normalizedValue”:”Rear panel grounding lug”,”value”:”Rear panel grounding lug”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); UL 1778″,”value”:”CSA (Canada); UL 1778″},{“name”:”Storage Elevation (ft.)”,”normalizedValue”:”0-32,808″,”value”:”0-32,808″},{“name”:”UPS Applications”,”normalizedValue”:”High-End Desktop/Small Network; Large Network”,”value”:”High-End Desktop/Small Network; Large Network”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-10,000″,”value”:”0-10,000″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”Product Compliance”,”normalizedValue”:”CE (Europe); FCC Part 15 Class B (USA)”,”value”:”CE (Europe); FCC Part 15 Class B (USA)”},{“name”:”Emergency Power Off (EPO)/Remote On-Off (ROO)”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”27″,”value”:”27″},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”3.4 x 17.2 x 23.7″,”value”:”3.400 x 17.200 x 23.700″},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Overall Depth”,”normalizedValue”:”23.7 in”,”value”:”23.7 in”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L5-30R”,”value”:”5-20R, L5-30R”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr, 3 yr (Registration)”,”value”:”2 yr, 3 yr Registration”},{“name”:”Battery Recharge Time”,”normalizedValue”:”5 hr”,”value”:”5 hr”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Surge Suppression Rating”,”normalizedValue”:”380 J”,”value”:”380 J”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Input Current – Maximum”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Power Rating – Real”,”normalizedValue”:”2.88 kW”,”value”:”2.88 kW”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Output Ports Included”,”normalizedValue”:”EPO, RS-232, SNMP, USB”,”value”:”EPO, RS-232, SNMP, USB”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 3kVA, Line Interactive, Out: 100/110/120/125V AC In: 120V AC”