UPS System, 3 kVA, 10 Outlets, Rack, Out: 120V AC , In:120V AC, Tripp Lite, Mfr#: SMART3000VS

$1494,99

UPS System, Line Interactive, Power Rating 3 kVA, Wattage 2.25 kW, Input Voltage 120V AC, Output Voltage 120V AC, Backup Time (Half/Full Load) 14 min/4 min, Mounting Rack, Outlet Type UPS/Surge, Number of Outlets 10, Medical Grade No, NEMA Receptacle Configuration 5-15/20R, 5-15R, L5-30R, NEMA Plug Configuration L5-30P, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 2 to 4 msec, Width 9 in, Depth 12 in, Height 14 in, Cord Length 8 ft, Display Type LCD, 60 Hz Hz

Out of stock

SKU: GRG6152894 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”3 kVA”,”rank”:4,”value”:”3 kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”2.25 kW”,”rank”:6,”value”:”2.25 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120V AC”,”rank”:8,”value”:”120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”14 min/4 min”,”rank”:9,”value”:”14 min/4 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”10″,”rank”:12,”value”:”10″},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Depth”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”value”:”UPS/Surge”},{“name”:”Special Features”,”normalizedValue”:”Cold Start Operation Supported, Hot Swappable Batteries”,”value”:”Cold Start Operation Supported, Hot Swappable Batteries”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Footnotes”,”normalizedValue”:”Slot for SNMPWEBCARD”,”value”:”Slot for SNMPWEBCARD”},{“name”:”Height”,”normalizedValue”:”14 in”,”value”:”14 in”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Input Current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Standards”,”normalizedValue”:”UL 1778″,”value”:”UL 1778″},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”3 kVA”,”value”:”3.0 kVA”},{“name”:”Includes”,”normalizedValue”:”PowerAlert Software and Cables”,”value”:”PowerAlert Software and Cables”},{“name”:”Watts”,”normalizedValue”:”2,250″,”value”:”2.25kW”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Ports”,”normalizedValue”:”EPO, RS232, Slot for SNMPWEBCARD, USB”,”value”:”EPO, RS232, Slot for SNMPWEBCARD, USB”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack”,”value”:”Rack”},{“name”:”Width”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L5-30R, 5-15/20R, 5-15R”,”value”:”5-15/20R, 5-15R, L5-30R”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Phase”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Watts – UPS Systems”,”normalizedValue”:”2.25 kW”,”value”:”2.25 kW”},{“name”:”Cord Length”,”normalizedValue”:”8 ft”,”value”:”8 ft”},{“name”:”Green Certification or Other Recognition”,”normalizedValue”:”UL1778 (USA)cUL (Canada)NOM (Mexico)Emissions: FCC Class A”,”value”:”UL1778 (USA)cUL (Canada)NOM (Mexico)Emissions: FCC Class A”},{“name”:”Capacity – Batteries”,”normalizedValue”:”3000 VA/2250 W”,”value”:”3000 VA/2250 W”},{“name”:”Housing Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”4 Minute/14 Minute”,”value”:”4 Minute/14 Minute”},{“name”:”Operating Temp. Range”,”normalizedValue”:”122u0026deg;F (50u0026deg;C)”,”value”:”122u0026deg;F (50u0026deg;C)”},{“name”:”Battery Type”,”normalizedValue”:”Sealed lead acid”,”value”:”Sealed Lead Acid (SLA)”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-15P Plug”,”value”:”NEMA 5-15P Plug”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”Output Capacity Details”,”normalizedValue”:”Output is reduced to 1600 watts maximum when used with external battery packs”,”value”:”Output is reduced to 1600 watts maximum when used with external battery packs”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”14.2 x 9.2 x 12″,”value”:”14.2 x 9.2 x 12″},{“name”:”Communications Cable”,”normalizedValue”:”2 USB and 2 DB9 cables included”,”value”:”2 USB and 2 DB9 cables included”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Sine wave”,”value”:”Sine wave”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”234″,”value”:”234″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD”,”value”:”SNMPWEBCARD; TLNETCARD; WEBCARDLX”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 95 and 104 are boosted by 12%”,”value”:”Input voltages between 95 and 104 are boosted by 12%”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC54″,”value”:”RBC54″},{“name”:”Output Receptacles”,”normalizedValue”:”5-15R; 5-15/20R, L5-30R”,”value”:”(7) 5-15R; (2) 5-15/20R; (1) L5-30R”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”120V 30A”,”value”:”120V 30A”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”480″,”value”:”480″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min”,”value”:”4 min. (2250w)”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”2,250″,”value”:”2250″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Audible Noise”,”normalizedValue”:”Audible Noise u003c 47dBA At Front Side 1 Meter”,”value”:”Audible Noise u003c 47dBA At Front Side 1 Meter”},{“name”:”UPS Certifications”,”normalizedValue”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”,”value”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”14 min”,”value”:”14 min. (1125w)”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”20A branch rated (x2) – breaker 1 protects 5-20R, breaker 2 protects 5-15R, L5-30R is unbreakered”,”value”:”20A branch rated (x2) – breaker 1 protects 5-20R, breaker 2 protects 5-15R, L5-30R is unbreakered”},{“name”:”Frequency Compatibility”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”147″,”value”:”147″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 128 and 147 are reduced by 12%”,”value”:”Input voltages between 128 and 147 are reduced by 12%”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Power Factor”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”30A”,”value”:”30A”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-2.25″,”value”:”-2.25″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”305″,”value”:”305″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”79″,”value”:”79″},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”UPS Housing Material”,”normalizedValue”:”Polycarbonate”,”value”:”Polycarbonate”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 79V to 147V”,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 79V to 147V”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”2.25″,”value”:”2.25″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”24 A”,”value”:”24A”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”361″,”value”:”361″},{“name”:”Communications Interface”,”normalizedValue”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”120v nominal output in battery mode”,”value”:”120v nominal output in battery mode”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 79 and 94 are boosted by 24%”,”value”:”Input voltages between 79 and 94 are boosted by 24%”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Three switchable two-outlet 5-15R load banks”,”value”:”Three switchable two-outlet 5-15R load banks”},{“name”:”Product Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122°F”,”value”:”122°F (50°C)”},{“name”:”Product Series”,”normalizedValue”:”VS”,”value”:”VS”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”14 min”,”value”:”14 Minute”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Plug/Connector Type”,”normalizedValue”:”NEMA L5-30P”,”value”:”NEMA L5-30P”},{“name”:”Product Name”,”normalizedValue”:”SmartPro VS Expandable Tower 3000VA UPS”,”value”:”SmartPro VS Expandable Tower 3000VA UPS”},{“name”:”Circuit Breaker”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Waveform Type”,”normalizedValue”:”Pulse-width Modulated Sine Wave”,”value”:”Pulse-width Modulated Sine Wave”},{“name”:”Product Type”,”normalizedValue”:”Line-interactive UPS”,”value”:”Line-interactive UPS”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Additional Information”,”normalizedValue”:”Supports Tripp Lite’s WatchDog software application to restore unresponsive programs by automatically restarting them and rebooting completely locked computers by automatically switching UPS power off and back on again, Communication ports support on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status messaging. Interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment”,”value”:”Supports Tripp Lite’s WatchDog software application to restore unresponsive programs by automatically restarting them and rebooting completely locked computers by automatically switching UPS power off and back on again, Communication ports support on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status messaging. Interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment”},{“name”:”Load Capacity”,”normalizedValue”:”3000 VA/2250 W”,”value”:”3000 VA/2250 W”},{“name”:”Status Indicators”,”normalizedValue”:”Battery Charge Level, AC Line Power, Voltage Regulation, UPS Load Level, Low Battery / Replace Battery”,”value”:”Battery Charge Level, AC Line Power, Voltage Regulation, UPS Load Level, Low Battery / Replace Battery”},{“name”:”Receptacle Detail”,”normalizedValue”:”1 x NEMA 5-15R, 7 x NEMA 5-20R, 2 x NEMA L5-30R”,”value”:”1 x NEMA 5-15R, 7 x NEMA 5-20R, 2 x NEMA L5-30R”},{“name”:”Surge Energy Rating”,”normalizedValue”:”480 J”,”value”:”480 J”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Chemistry”,”normalizedValue”:”Lead Acid”,”value”:”Lead Acid”},{“name”:”Battery Life”,”normalizedValue”:”6 yr”,”value”:”6 Year”},{“name”:”Battery Characteristics”,”normalizedValue”:”Maintenance-free”,”value”:”Maintenance-free”},{“name”:”Product Line”,”normalizedValue”:”SmartPro”,”value”:”SmartPro”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro VS Expandable Tower 3000VA UPS, SMART 3000VS UPS System, PowerAlert Software and cabling, Warranty information, Instruction manual”,”value”:”SmartPro VS Expandable Tower 3000VA UPS, SMART 3000VS UPS System, PowerAlert Software and cabling, Warranty information, Instruction manual”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Alarm”,”normalizedValue”:”Power Failure, Low Battery, Overload”,”value”:”Power Failure, Low Battery, Overload”},{“name”:”Certifications u0026 Standards”,”normalizedValue”:”UL1778 (USA), cUL (Canada), NOM (Mexico), Emissions: FCC Class A”,”value”:”UL1778 (USA), cUL (Canada), NOM (Mexico), Emissions: FCC Class A”},{“name”:”Total Number of Expansion Slots”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”2,250″,”value”:”2250″},{“name”:”UPS Applications”,”normalizedValue”:”Large Network”,”value”:”Large Network”},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”14 min”,”value”:”14 min. (1125W)”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”4 min”,”value”:”4 min. (2250W)”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Package Includes”,”normalizedValue”:”SMART 3000VS UPS System;USB u0026 DB9 Cables;Instruction manual”,”value”:”SMART 3000VS UPS System;USB u0026 DB9 Cables;Instruction manual”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 3 kVA, 10 Outlets, Rack, Out: 120V AC , In:120V AC, Tripp Lite, Mfr#: SMART3000VS”