Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”2 kVA”,”rank”:4,”value”:”2kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”1.8 kW”,”rank”:6,”value”:”1.8 kW”},{“name”:”Input Voltage”,”normalizedValue”:”100/115/120/127V AC”,”rank”:7,”value”:”100/115/120/127V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/115/120/127V AC”,”rank”:8,”value”:”100/110/115/120/127V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”20.2 min/7.7 min”,”rank”:9,”value”:”20.2 min/7.7 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”7″,”rank”:12,”value”:”7″},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Includes”,”normalizedValue”:”DB9 RS232 Cable, Rack Mounting Hardware, Tower Support Stands, USB Cables”,”value”:”DB9 RS232 Cable, Rack Mounting Hardware, Tower Support Stands, USB Cables”},{“name”:”Standards”,”normalizedValue”:”cUL, UL”,”value”:”cUL, UL”},{“name”:”Width”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Depth”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Input Current”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L5-20R, 5-15/20R”,”value”:”(6) 5-15/20R; (1) L5-20R”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”2.2 kVA”,”value”:”2.2 kVA”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Overall Height”,”normalizedValue”:”3.41 in”,”value”:”3.41 in”},{“name”:”Overall Width”,”normalizedValue”:”17.33 in”,”value”:”17.33 in”},{“name”:”Battery Type”,”normalizedValue”:”Sealed Lead Acid”,”value”:”Sealed Lead Acid (SLA)”},{“name”:”Capacity – Batteries”,”normalizedValue”:”2200 VA/1800 W”,”value”:”2200 VA/1800 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-20P Plug”,”value”:”NEMA 5-20P Plug”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load”,”value”:”100V at full load (90V full load at 100V nominal setting); 70V at 70% load; 55V at 33% load”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Switches”,”normalizedValue”:”2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options”,”value”:”2 switches control off/on power status and alarm-cancel operation; 2 additional scroll-down and scroll-up / select options enable LCD status viewing and configuration options”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages”,”value”:”Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and overvoltages”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages to 150V (0-100% load)”,”value”:”Corrects overvoltages to 150V (0-100% load)”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”2.2″,”value”:”2.2″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 3 hours recharge to 90% (typical, full load discharge)”,”value”:”Less than 3 hours recharge to 90% (typical, full load discharge)”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”26″,”value”:”26″},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access”,”value”:”Front panel battery access”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”120V factory default”,”value”:”120V factory default”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC”,”value”:”100V AC; 110V AC; 115V AC; 120V AC; 127V AC”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC94-2U”,”value”:”RBC94-2U”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Power Factor”,”normalizedValue”:”0.82″,”value”:”0.82″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.”,”value”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz.”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Certifications”,”normalizedValue”:”ENERGY STAR Qualified; Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to UL1778 (USA)”,”value”:”ENERGY STAR Qualified; Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to UL1778 (USA)”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min”,”value”:”4 min. (1800w)”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.5 x 17.5 x 19″,”value”:”3.5 x 17.5 x 19″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages to 100V at full load (90V at 100V nominal)”,”value”:”Corrects undervoltages to 100V at full load (90V at 100V nominal)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”LED Indicators”,”normalizedValue”:”7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status”,”value”:”7 front panel LEDs indicate line power availability, AC to DC conversion, battery mode operation, inverter mode, eco mode operation, bypass mode operation and AC output status”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”20A 120V”,”value”:”20A 120V”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable three-outlet 5-15/20R load banks”,”value”:”Two switchable three-outlet 5-15/20R load banks”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Corrects brownouts to 70V (70% load) \u0026 55V (33% load)”,”value”:”Corrects brownouts to 70V (70% load) \u0026 55V (33% load)”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”1.8″,”value”:”1.8″},{“name”:”Output Capacity Details”,”normalizedValue”:”ON LINE MODE: Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal; FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts / 115V 1134 watts / 110V 1071 watts / 100V 1008 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”,”value”:”ON LINE MODE: Maximum output capacity is reduced to 1620 watts at 115V nominal and 1440 watts at 100V nominal; FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts / 115V 1134 watts / 110V 1071 watts / 100V 1008 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”2,200″,”value”:”2200″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”483″,”value”:”483″},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”392″,”value”:”392″},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Audible Noise”,”normalizedValue”:”57 dBA at 1m front side”,”value”:”57 dBA at 1m front side”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min”,”value”:”12 min. (900w)”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”,”value”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”,”value”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”100 V, 110 V, 115 V, 120 V, 127 V”,”value”:”100V; 110V; 115V; 120V; 127V”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”,”value”:”Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,085″,”value”:”1085″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”Up to 3000m”,”value”:”Up to 3000m”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”16 A”,”value”:”16A”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 3%”,”value”:”+/- 3%”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”684″,”value”:”684″},{“name”:”Input Circuit Breakers”,”normalizedValue”:”30A”,”value”:”30A”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,800″,”value”:”1800″},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Load Capacity”,”normalizedValue”:”2200 VA/1800 W”,”value”:”2200 VA/1800 W”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic, Internal”,”value”:”Internal, Automatic”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU2200RTXLCD2U 2200VA Tower/Rack Mountable UPS, PowerAlert UPS Monitoring Software CD, USB Cable, RS-232 Cable, EPO (RJ11) Cable, 4-Post Rail Kit, Owner’s Manual, 2 x Bolt-on Mounting Ears”,”value”:”SmartOnline SU2200RTXLCD2U 2200VA Tower/Rack Mountable UPS, PowerAlert UPS Monitoring Software CD, USB Cable, RS-232 Cable, EPO (RJ11) Cable, 4-Post Rail Kit, Owner’s Manual, 2 x Bolt-on Mounting Ears”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert UPS Monitoring Software”,”value”:”PowerAlert UPS Monitoring Software”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Product Certifications”,”normalizedValue”:”UL Listed; cUL Listed”,”value”:”UL Listed; cUL Listed”},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”3.41 x 17.33 x 23.82″,”value”:”3.410 x 17.330 x 23.820″},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”91.4″,”value”:”91.4″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”1,800″,”value”:”1800″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”2,000″,”value”:”2000″},{“name”:”Power Factor (Input)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”26.8″,”value”:”26.8″},{“name”:”Product Compliance”,”normalizedValue”:”CE (Europe); FCC (USA)”,”value”:”CE (Europe); FCC (USA)”},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”578″,”value”:”578″},{“name”:”Package Includes”,”normalizedValue”:”2000VA 1800W 120V Double-Conversion UPS;USB cable;DB9 RS232 cable;Rack-mounting hardware;Tower support stands;Safety instructions;Quick start guide”,”value”:”2000VA 1800W 120V Double-Conversion UPS;USB cable;DB9 RS232 cable;Rack-mounting hardware;Tower support stands;Safety instructions;Quick start guide”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Output Ports Included”,”normalizedValue”:”RS-232, USB”,”value”:”RS-232, USB”},{“name”:”Overall Depth”,”normalizedValue”:”23.8 in”,”value”:”23.8 in”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”190 J”,”value”:”190 J”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”,”value”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”744-A3121″,”value”:”744-A3121″},{“name”:”Input Current – Maximum”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Battery Recharge Time”,”normalizedValue”:”3 hr”,”value”:”3 hr”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP72RT”,”value”:”BP72RT”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L5-20R”,”value”:”5-20R, L5-20R”},{“name”:”Power Rating – Real”,”normalizedValue”:”1.8 kW”,”value”:”1.8 kW”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.