Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1 kVA”,”rank”:4,”value”:”1kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”800 W”,”rank”:6,”value”:”800 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V”,”rank”:8,”value”:”110/115/120V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”15 min/5.3 min”,”rank”:9,”value”:”15 min/5.3 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Ports”,”normalizedValue”:”EPO, RS232, Slot for SNMPWEBCARD, USB”,”value”:”EPO, RS232, Slot for SNMPWEBCARD, USB”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Footnotes”,”normalizedValue”:”Slot for SNMPWEBCARD”,”value”:”Slot for SNMPWEBCARD”},{“name”:”Includes”,”normalizedValue”:”DB9 Cable, EPO Cables, Mounting Hardware, SMART1000RM2U SmartPro120V 1kVA 800W Line-Interactive Sine Wave UPS, USB Cables”,”value”:”DB9 Cable, EPO Cables, Mounting Hardware, SMART1000RM2U SmartPro120V 1kVA 800W Line-Interactive Sine Wave UPS, USB Cables”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(6) 5-15R”},{“name”:”Depth”,”normalizedValue”:”13 in”,”value”:”13 in”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Height”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Input Current”,”normalizedValue”:”9.2 A”,”value”:”9.2 A”},{“name”:”Special Features”,”normalizedValue”:”Hot Swappable Batteries”,”value”:”Hot Swappable Batteries”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1 kVA”,”value”:”1.0 kVA”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class B (USA), NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class B (USA), NOM (Mexico), RoHS, UL1778″},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Width”,”normalizedValue”:”13 in”,”value”:”13 in”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Overall Width”,”normalizedValue”:”17.35 in”,”value”:”17.35 in”},{“name”:”Overall Height”,”normalizedValue”:”3.45 in”,”value”:”3.45 in”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-15P Plug”,”value”:”NEMA 5-15P Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Audible Noise”,”normalizedValue”:”45 dBA maximum, front side 1m”,”value”:”45 dBA maximum, front side 1m”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.45 x 17.35 x 12.5″,”value”:”3.45 x 17.35 x 12.5″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”15.5″,”value”:”15.5″},{“name”:”Grounding Lug”,”normalizedValue”:”Back panel grounding lug”,”value”:”Back panel grounding lug”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”9.2 A”,”value”:”9.2A”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”134″,”value”:”134″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable two-outlet 5-15R load banks”,”value”:”Two switchable two-outlet 5-15R load banks”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Power Factor”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”83″,”value”:”83″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-21%, +8%”,”value”:”-21%, +8%”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”147″,”value”:”147″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”,”value”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”600″,”value”:”600″},{“name”:”Switches”,”normalizedValue”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions”,”value”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”15 min”,”value”:”15 min. (400w)”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 128 and 147 are reduced by 12%”,”value”:”Input voltages between 128 and 147 are reduced by 12%”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Communications Interface”,”normalizedValue”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”Current version uses RBC24V-LCD ; Prior versions used RBC92-2U ; Check the label inside the battery door to verify the appropriate replacement battery part number”,”value”:”Current version uses RBC24V-LCD ; Prior versions used RBC92-2U ; Check the label inside the battery door to verify the appropriate replacement battery part number”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”318″,”value”:”318″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147″},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”5 min 18 sec”,”value”:”5.3 min. (800w)”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”15A”,”value”:”15A”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 83 and 107 are boosted by 14%”,”value”:”Input voltages between 83 and 107 are boosted by 14%”},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.95″,”value”:”0.95″},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”88″,”value”:”88″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Waveform Type”,”normalizedValue”:”Sine Wave”,”value”:”Sine Wave”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Total Number of Expansion Slots”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Load Capacity”,”normalizedValue”:”1000 VA/800 W”,”value”:”1000 VA/800 W”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Alarm”,”normalizedValue”:”Low Battery, Overload, On Battery”,”value”:”Low Battery, Overload, On Battery”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104°F”,”value”:”104°F (40°C)”},{“name”:”Package Contents”,”normalizedValue”:”SMART1000RM2U UPS System, PowerAlert Software CD, Serial & EPO Cabling, 4 x Post Rackmount Installation Kit, Instruction Manual”,”value”:”SMART1000RM2U UPS System, PowerAlert Software CD, Serial & EPO Cabling, 4 x Post Rackmount Installation Kit, Instruction Manual”},{“name”:”UPS Applications”,”normalizedValue”:”Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”,”value”:”Large Network; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Package Includes”,”normalizedValue”:”SMART1000RM2U SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS;USB cable;DB9 cable;EPO cable;Mounting hardware;Owner’s manual”,”value”:”SMART1000RM2U SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS;USB cable;DB9 cable;EPO cable;Mounting hardware;Owner’s manual”},{“name”:”Grounding Details”,”normalizedValue”:”Back panel grounding lug”,”value”:”Back panel grounding lug”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Power Rating – Real”,”normalizedValue”:”800 W”,”value”:”800 W”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”570 J”,”value”:”570 J”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 hr”},{“name”:”Overall Depth”,”normalizedValue”:”12-1/2 in”,”value”:”12.5 in”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”,”value”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Input Current – Maximum”,”normalizedValue”:”9.2 A”,”value”:”9.2 A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.