Description
[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”16 kVA”,”rank”:2,”value”:”16.0 kVA”},{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”14.4 kW”,”rank”:3,”value”:”14.4 kW”},{“name”:”Power Rating”,”normalizedValue”:”16 kVA”,”rank”:4,”value”:”16 kVA”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”120V AC, 208V AC, 240V AC”,”rank”:4,”value”:”120V AC, 208V AC, 240V AC”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”208V AC, 240V AC”,”rank”:5,”value”:”208V AC, 240V AC”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”14.4 kW”,”rank”:6,”value”:”14.4 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120/208/240V AC”,”rank”:7,”value”:”120/208/240V AC”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”Hardwired”,”rank”:8,”value”:”Hardwired”},{“name”:”Output Voltage”,”normalizedValue”:”208/240V AC”,”rank”:8,”value”:”208/240V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”13.5 min/5.5 min”,”rank”:9,”value”:”13.5 min/5.5 min”},{“name”:”Outlet Type”,”normalizedValue”:”Hardwired”,”rank”:10,”value”:”Hardwired”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”14″,”rank”:12,”value”:”14″},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Watts”,”normalizedValue”:”14,400″,”value”:”14.4kW”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Depth”,”normalizedValue”:”22 in”,”value”:”22 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”No Configuration”,”value”:”No Configuration”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Includes”,”normalizedValue”:”(4) Post Rack Mount Installation Rails, SU6000XFMR2U 208/240V to 120V Transformer, SUPDMB20K Parallel PDU with Bypass Switch, Two BP240V10RT3U Battery Packs, USB, DB9 and EPO Cabling”,”value”:”(4) Post Rack Mount Installation Rails, SU6000XFMR2U 208/240V to 120V Transformer, SUPDMB20K Parallel PDU with Bypass Switch, Two BP240V10RT3U Battery Packs, USB, DB9 and EPO Cabling”},{“name”:”Input Current”,”normalizedValue”:”88.4 A”,”value”:”88.4 A”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack”,”value”:”Rack”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Width”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, RoHS, UL1778″},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Cord Length”,”normalizedValue”:”No Cord”,”value”:”No Cord”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Overall Width”,”normalizedValue”:”17.52 in”,”value”:”17.52 in”},{“name”:”Overall Height”,”normalizedValue”:”5.16 in”,”value”:”5.16 in”},{“name”:”Input Connection”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Type”,”normalizedValue”:”Lead Acid”,”value”:”Valve Regulated Lead Acid (VRLA)”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”5.5 minutes (14,400 watts)”,”value”:”5.5 minutes (14,400 watts)”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”208 V AC, 240 V AC”,”value”:”208V AC; 240V AC”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages as low as 100V”,”value”:”Corrects undervoltages as low as 100V”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)”,”value”:”2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”},{“name”:”Rack Height”,”normalizedValue”:”14 U”,”value”:”14U”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”240″,”value”:”240″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Audible Noise”,”normalizedValue”:”60 dBA at front side 1 meter”,”value”:”60 dBA at front side 1 meter”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-3000m (0 to 10,000 ft.)”,”value”:”0-3000m (0 to 10,000 ft.)”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Applications utilizing any supported network management card option, require the installation of two of the same model network card to install one card per included UPS power module; RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module”,”value”:”Applications utilizing any supported network management card option, require the installation of two of the same model network card to install one card per included UPS power module; RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module”},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”5 sets of adjustable 4 post rack rails included (one for each included 2U/3U module)”,”value”:”5 sets of adjustable 4 post rack rails included (one for each included 2U/3U module)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”Output Receptacle Details”,”normalizedValue”:”Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input. Additional 120V capacity is available by adding a second SU6000XFMR2U step-down transformer.”,”value”:”Total 120V output is limited to 4992 watts for 208V input and 5760 watts for 240V input. Additional 120V capacity is available by adding a second SU6000XFMR2U step-down transformer.”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fans”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”445″,”value”:”445″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”300V”,”value”:”300V”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”16″,”value”:”16″},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”32.5″,”value”:”32.5″},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”4,864″,”value”:”4864″},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”656″,”value”:”656″},{“name”:”Output Receptacles”,”normalizedValue”:”L6-30R, 5-15R; 5-15/20R, C19″,”value”:”(4) 5-15R; (8) 5-15/20R; (2) L6-30R; (8) C19″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”2% output voltage regulation in standard online, double-conversion mode”,”value”:”2% output voltage regulation in standard online, double-conversion mode”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs”,”value”:”For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”16,000″,”value”:”16000″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”88.4A (208V), 76.6A (240V)”,”value”:”88.4A (208V), 76.6A (240V)”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”5.14 x 17.5 x 25.82″,”value”:”5.14 x 17.50 x 25.82″},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages up to 300V”,”value”:”Corrects overvoltages up to 300V”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”UPS Dimensions Details”,”normalizedValue”:”Includes 2 SU8000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs, 1 SU6000XFMR2U transformer and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module, battery pack and transformer each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”,”value”:”Includes 2 SU8000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs, 1 SU6000XFMR2U transformer and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module, battery pack and transformer each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”14,400″,”value”:”14400″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,565″,”value”:”2565″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”POWER MODULE: Two built-in 30A breakers protect one L6-30R outlet each, Eight built-in 20A breakers protect one C19 outlet each; TRANSFORMER MODULE: Two 15A breakers protect 2 5-15R outlets each, Two 20A breakers protect 4 5-15/20R outlets each”,”value”:”POWER MODULE: Two built-in 30A breakers protect one L6-30R outlet each, Eight built-in 20A breakers protect one C19 outlet each; TRANSFORMER MODULE: Two 15A breakers protect 2 5-15R outlets each, Two 20A breakers protect 4 5-15/20R outlets each”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)”,”value”:”This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V, 208 V, 240 V”,”value”:”120V; 208V; 240V”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”37.5″,”value”:”37.5″},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable external battery packs”,”value”:”Hot-swappable, user replaceable external battery packs”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency regulation +/- 0.05Hz (free running)”,”value”:”Output frequency regulation +/- 0.05Hz (free running)”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI)”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP240V10RT3U; BP240V787C-1PH”,”value”:”BP240V10RT3U; BP240V787C-1PH”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”5,464″,”value”:”5464″},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”14.4″,”value”:”14.4″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”100V”,”value”:”100V”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”131″,”value”:”131″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Runtime is expandable with external battery packs”,”value”:”Runtime is expandable with external battery packs”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 minutes (7200 watts)”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD”},{“name”:”Frequency Compatibility”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”240V, 100A @ 208V”,”value”:”100A @ 208V, or 240V (L1, L2, G)”},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-3000 m”,”value”:”0-3000 m”},{“name”:”UPS Input Connection Description”,”normalizedValue”:”3 wire single phase input (L1, L2, G)”,”value”:”3 wire single phase input (L1, L2, G)”},{“name”:”Stepdown Transformer Dimensions (hwd / in.)”,”normalizedValue”:”3.5 x 17.5 x 21.8″,”value”:”3.50 x 17.50 x 21.80″},{“name”:”Input Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Product Series”,”normalizedValue”:”EZ”,”value”:”EZ”},{“name”:”Output Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Plug/Connector Type”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Modular Slots”,”normalizedValue”:”Communications Slot”,”value”:”Communications Slot”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Additional Information”,”normalizedValue”:”Output Receptacles: 8 x C19″,”value”:”Output Receptacles: 8 x C19″},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic, Manual”,”value”:”Manual, Automatic”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline EZ SU16KRT-1TF 16kVA Tower/Rack Mountable UPS, 2 x Power Modules, 2 x Battery Packs, 1 x Transformer, L6-30R / C19 Parallel PDU with Bypass Switch, 5 x Set of 4 post Rackmount Installation Rails, PowerAlert Software CD, USB Cable, Serial Cable, EPO Cable”,”value”:”SmartOnline EZ SU16KRT-1TF 16kVA Tower/Rack Mountable UPS, 2 x Power Modules, 2 x Battery Packs, 1 x Transformer, L6-30R / C19 Parallel PDU with Bypass Switch, 5 x Set of 4 post Rackmount Installation Rails, PowerAlert Software CD, USB Cable, Serial Cable, EPO Cable”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Name”,”normalizedValue”:”SmartOnline EZ SU16KRT-1TF 16kVA Tower/Rack Mountable UPS”,”value”:”SmartOnline EZ SU16KRT-1TF 16kVA Tower/Rack Mountable UPS”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 Hour”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Receptacle Detail”,”normalizedValue”:”2 x NEMA L6-30R, 4 x NEMA 5-15R, 8 x IEC 60320 C19, 8 x NEMA 5-15/20R”,”value”:”2 x NEMA L6-30R, 4 x NEMA 5-15R, 8 x IEC 60320 C19, 8 x NEMA 5-15/20R”},{“name”:”Product Type”,”normalizedValue”:”Double Conversion Online UPS”,”value”:”Double Conversion Online UPS”},{“name”:”Overload Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.50 Minute”},{“name”:”Load Capacity”,”normalizedValue”:”16 kVA”,”value”:”16 kVA”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”5.50 Minute”,”value”:”5.50 Minute”},{“name”:”Product Line”,”normalizedValue”:”SmartOnline”,”value”:”SmartOnline”},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); UL 1778″,”value”:”IEC 61000; CSA (Canada); UL 1778″},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 min. (7200W)”},{“name”:”Package Includes”,”normalizedValue”:”Two SU8000RT3UPM UPS power modules;Two BP240V10RT3U battery packs;One SU6000XFMR2U 208/240V to 120V transformer;SUPDMB20K parallel PDU with Bypass switch;4 post rackmount installation rails;USB, DB9 \u0026 EPO cabline”,”value”:”Two SU8000RT3UPM UPS power modules;Two BP240V10RT3U battery packs;One SU6000XFMR2U 208/240V to 120V transformer;SUPDMB20K parallel PDU with Bypass switch;4 post rackmount installation rails;USB, DB9 \u0026 EPO cabline”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”16,000″,”value”:”16000″},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”5,464″,”value”:”5464″},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”4,864″,”value”:”4864″},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”5 min 30 sec”,”value”:”5.5 min. (14.4kW)”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”14,400″,”value”:”14400″},{“name”:”Unit Dimension Details”,”normalizedValue”:”Includes 2 SU8000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs, 1 SU6000XFMR2U transformer and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module, battery pack and transformer each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”,”value”:”Includes 2 SU8000RT3UPM UPS/Power modules, 2 BP240V10RT3U Battery packs, 1 SU6000XFMR2U transformer and SUPDMB20K parallel bypass PDU; Listed weights and dimensions for UPS/Power module, battery pack and transformer each refer to a single unit; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with parallel bypass PDU installed”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Input Current – Minimum”,”normalizedValue”:”76.6 A”,”value”:”76.6 A”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Power Cord Length”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Number of Outlets – UPS”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, 5-15R, C19, L6-30R”,”value”:”5-20R, 5-15R, C19, L6-30R”},{“name”:”Power Rating – Real”,”normalizedValue”:”14.4 kW”,”value”:”14.4 kW”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Plug Configuration”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”2,565 J”,”value”:”2,565 J”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Transfer Time – Maximum”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Run Time – Full Load”,”normalizedValue”:”5 min 30 sec”,”value”:”5.5 min”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP240V10RT3U, BP240V787C-1PH”,”value”:”BP240V10RT3U, BP240V787C-1PH”},{“name”:”Input Current – Maximum”,”normalizedValue”:”88.4 A”,”value”:”88.4 A”},{“name”:”Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 hr”},{“name”:”Power Rating – Apparent”,”normalizedValue”:”16 kVA”,”value”:”16 kVA”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Run Time – Half Load”,”normalizedValue”:”13 min 30 sec”,”value”:”13.5 min”},{“name”:”Overall Depth”,”normalizedValue”:”25.83 in”,”value”:”25.83 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.