Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1,500 VA”,”rank”:4,”value”:”1500VA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”810 W”,”rank”:6,”value”:”810 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V AC”,”rank”:8,”value”:”110/115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”7.5 min/1.8 min”,”rank”:9,”value”:”7.5 min/1.8 min”},{“name”:”Outlet Type”,”normalizedValue”:”(5) Surge; (5) UPS/Surge”,”rank”:10,”value”:”(5) Surge; (5) UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”10″,”rank”:12,”value”:”10″},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Transfer Time”,”normalizedValue”:”2 milliseconds (AC to battery mode), 6 milliseconds (battery to AC mode)”,”value”:”2 milliseconds (AC to battery mode), 6 milliseconds (battery to AC mode)”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Width”,”normalizedValue”:”15.6 in”,”value”:”15.6 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(10) 5-15R”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set)”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set)”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”Hot-Swap PDU options”,”normalizedValue”:”PDUB15 (2U / 8 5-15R outlets)”,”value”:”PDUB15 (2U / 8 5-15R outlets)”},{“name”:”Communications Cable”,”normalizedValue”:”USB cabling included”,”value”:”USB cabling included”},{“name”:”Operating Temperature Range”,”normalizedValue”:”32° to 104°F (0° to 40°C)”,”value”:”32° to 104°F (0° to 40°C)”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”396″,”value”:”396″},{“name”:”Input Circuit Breakers”,”normalizedValue”:”15A”,”value”:”15A”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”203″,”value”:”203″},{“name”:”Switches”,”normalizedValue”:”Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test”,”value”:”Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 92 and 108 are boosted by 18%”,”value”:”Input voltages between 92 and 108 are boosted by 18%”},{“name”:”Relative Humidity”,”normalizedValue”:”5 to 95%, non-condensing”,”value”:”5 to 95%, non-condensing”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery conditions”,”value”:”Audible alarm indicates power-failure and low-battery conditions”},{“name”:”Package Includes”,”normalizedValue”:”1500VA 810W 120V Line-Interactive UPS;USB cable;Owner’s manual”,”value”:”1500VA 810W 120V Line-Interactive UPS;USB cable;Owner’s manual”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”8 x 5.75 x 15.6″,”value”:”8 x 5.75 x 15.6″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic Voltage Regulation (AVR); Surge/noise protection”,”value”:”Automatic Voltage Regulation (AVR); Surge/noise protection”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”92″,”value”:”92″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 8 hours from 10% to 90%”,”value”:”Less than 8 hours from 10% to 90%”},{“name”:”UPS Applications”,”normalizedValue”:”Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”,”value”:”Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”120V”,”value”:”120V (+9% / -12%)”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”810″,”value”:”810″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 129 and 147 are reduced by 15%”,”value”:”Input voltages between 129 and 147 are reduced by 15%”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”12 A”,”value”:”12A”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”650″,”value”:”650″},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”120V (±10%)”,”value”:”120V (±10%)”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes”,”value”:”LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”826″,”value”:”826″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Storage Temperature Range”,”normalizedValue”:”5° to 122°F”,”value”:”5° to 122°F (-15° to 50°C)”},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”8 x 5.75 x 15.6″,”value”:”8.000 x 5.750 x 15.600″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.95″,”value”:”0.95″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC51 (requires 2)”,”value”:”RBC51 (requires 2)”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Automatic frequency selection”,”value”:”Automatic frequency selection”},{“name”:”Product Compliance”,”normalizedValue”:”ENERGY STAR Qualified; FCC Part 15 Class B (USA)”,”value”:”ENERGY STAR Qualified; FCC Part 15 Class B (USA)”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”98″,”value”:”98″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.