UPS System, 10 kVA, On-Line/Double Conversion, Out: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC

$7576,99

UPS System, Online Double Conversion, Power Rating 10 kVA, Wattage 9 kW, Input Voltage 200V AC, 208V AC, 220V AC, 230V AC, 240V AC, Output Voltage 200V AC, 208V AC, 220V AC, 230V AC, 240V AC, Backup Time (Half/Full Load) 12.5 min/4.3 min, Mounting Rack, Outlet Type Hardwired, Number of Outlets 6, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration No Configuration, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 26 in

Out of stock

SKU: GRG2199867 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”10 kVA”,”rank”:2,”value”:”10.0 kVA”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”9 kW”,”rank”:3,”value”:”9.0 kW”},{“name”:”UPS Type”,”normalizedValue”:”Double Conversion, On-Line”,”rank”:3,”value”:”On-Line/Double Conversion”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”200V AC, 208V AC, 220V AC, 230V AC, 240V AC”,”rank”:4,”value”:”200V AC, 208V AC, 220V AC, 230V AC, 240V AC”},{“name”:”Power Rating”,”normalizedValue”:”10 kVA”,”rank”:4,”value”:”10 kVA”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”200V AC, 208V AC, 220V AC, 230V AC, 240V AC”,”rank”:5,”value”:”200V AC, 208V AC, 220V AC, 230V AC, 240V AC”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”9 kW”,”rank”:6,”value”:”9 kW”},{“name”:”Input Voltage”,”normalizedValue”:”200V AC; 208V AC; 220V AC; 230V AC; 240V AC”,”rank”:7,”value”:”200V AC; 208V AC; 220V AC; 230V AC; 240V AC”},{“name”:”Output Voltage”,”normalizedValue”:”200V AC; 208V AC; 220V AC; 230V AC; 240V AC”,”rank”:8,”value”:”200V AC; 208V AC; 220V AC; 230V AC; 240V AC”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”Hardwired”,”rank”:8,”value”:”Hardwired”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”12.5 min/4.3 min”,”rank”:9,”value”:”12.5 min/4.3 min”},{“name”:”Outlet Type”,”normalizedValue”:”Hardwired”,”rank”:10,”value”:”Hardwired”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Height”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack”,”value”:”Rack”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Watts”,”normalizedValue”:”9,000″,”value”:”9kW”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″,”value”:”CE (Europe), CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, NOM (Mexico), RoHS, UL1778″},{“name”:”Depth”,”normalizedValue”:”26 in”,”value”:”26 in”},{“name”:”Includes”,”normalizedValue”:”(4) Post Compatible Rack Rail Kit (2 Sets), BP240V10RT3U External Battery Pack, SUPDMB710IEC Detachable PDU with Manual Bypass Switch, USB, DB9 and EPO Cabling”,”value”:”(4) Post Compatible Rack Rail Kit (2 Sets), BP240V10RT3U External Battery Pack, SUPDMB710IEC Detachable PDU with Manual Bypass Switch, USB, DB9 and EPO Cabling”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Input Current”,”normalizedValue”:”56.1 A”,”value”:”56.1 A”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”No Configuration”,”value”:”No Configuration”},{“name”:”Cord Length”,”normalizedValue”:”No Cord”,”value”:”No Cord”},{“name”:”Width”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Overall Height”,”normalizedValue”:”5.16 in”,”value”:”5.16 in”},{“name”:”Overall Width”,”normalizedValue”:”17.52 in”,”value”:”17.52 in”},{“name”:”Input Connection”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”445″,”value”:”445″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”2 sets of adjustable 4 post rack rails included”,”value”:”2 sets of adjustable 4 post rack rails included”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Rack Height”,”normalizedValue”:”6 U”,”value”:”6U”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”5.14 x 17.5 x 25.82″,”value”:”5.14 x 17.5 x 25.82″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (No de-rating); Output frequency regulation +/- 0.05Hz (free running)”,”value”:”Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (No de-rating); Output frequency regulation +/- 0.05Hz (free running)”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP240V10RT3U ; BP240V787C-1PH”,”value”:”BP240V10RT3U ; BP240V787C-1PH”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)”,”value”:”56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”2% output voltage regulation in standard online, double-conversion mode”,”value”:”2% output voltage regulation in standard online, double-conversion mode”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”300V”,”value”:”300V”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”Voltage selection via front panel LCD interface”,”value”:”Voltage selection via front panel LCD interface”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages up to 300V”,”value”:”Corrects overvoltages up to 300V”},{“name”:”Frequency Compatibility”,”normalizedValue”:”50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion”,”value”:”50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable external battery packs”,”value”:”Hot-swappable, user replaceable external battery packs”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”10,000″,”value”:”10000″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”131″,”value”:”131″},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-3000 m”,”value”:”0-3000 m”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,280″,”value”:”1280″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”20A double-pole (x6) protects 1 C19 outlet each”,”value”:”20A double-pole (x6) protects 1 C19 outlet each”},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”37.5″,”value”:”37.5″},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-3000m (0 to 10,000 ft.)”,”value”:”0-3000m (0 to 10,000 ft.)”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”4,593″,”value”:”4593″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”656″,”value”:”656″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”240″,”value”:”240″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”3,415″,”value”:”3415″},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”,”value”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages as low as 100V”,”value”:”Corrects undervoltages as low as 100V”},{“name”:”Voltage Compatibility (VAC)”,”normalizedValue”:”200, 208, 230, 240, 220″,”value”:”200; 208; 230; 240; 220″},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A (EMI)”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”33″,”value”:”33″},{“name”:”UPS Input Connection Description”,”normalizedValue”:”Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring”,”value”:”Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring”},{“name”:”UPS Dimensions Details”,”normalizedValue”:”Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710IEC PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”,”value”:”Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710IEC PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”9″,”value”:”9″},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Transfer Time (Economy Mode)”,”normalizedValue”:”8 ms. typical power failure response in optional economy mode”,”value”:”8 ms. typical power failure response in optional economy mode”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”,”value”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”200 V AC, 208 V AC, 220 V AC, 230 V AC, 240 V AC”,”value”:”200V AC; 208V AC; 220V AC; 230V AC; 240V AC”},{“name”:”Power Factor”,”normalizedValue”:”0, 9″,”value”:”0,9″},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”200 V, 208 V, 220 V, 230 V, 240 V”,”value”:”200V; 208V; 220V; 230V; 240V”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Output Receptacles”,”normalizedValue”:”C19″,”value”:”(6) C19″},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”9,000″,”value”:”9000″},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,565″,”value”:”2565″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime with optional external battery packs”,”value”:”Supports extended runtime with optional external battery packs”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.91″,”value”:”0.91″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 18 sec”,”value”:”4.3 min. (9000w)”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”Economy Mode Operation”,”normalizedValue”:”Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”,”value”:”Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”60A”,”value”:”60A”},{“name”:”Audible Noise”,”normalizedValue”:”60 dBA at front side 1 meter”,”value”:”60 dBA at front side 1 meter”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min 30 sec”,”value”:”12.5 min. (4500w)”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 8 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 8 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”100V”,”value”:”100V”},{“name”:”Plug/Connector Type”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Storage Temperature”,”normalizedValue”:”5 to 122°F”,”value”:”5°F (-15°C) – 122°F (50°C)”},{“name”:”EMI/RFI Noise Filter”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Bypass Switch”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”4.30 Minute”,”value”:”4.30 Minute”},{“name”:”Input Frequency”,”normalizedValue”:”50 Hz”,”value”:”50 Hz”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU10000RT3UG 10kVA Tower/Rack-mountable UPS, 3U power module with detachable hot-swap PDU input/output panel and bypass switch, 3U external battery pack, Two sets of 4 post rackmount rails (one for each of the 3U components), One set of tower stands for upright tower con”,”value”:”SmartOnline SU10000RT3UG 10kVA Tower/Rack-mountable UPS, 3U power module with detachable hot-swap PDU input/output panel and bypass switch, 3U external battery pack, Two sets of 4 post rackmount rails (one for each of the 3U components), One set of tower stands for upright tower con”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104°F”,”value”:”104°F (40°C)”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 Hour”},{“name”:”Output Frequency”,”normalizedValue”:”50 Hz”,”value”:”50 Hz”},{“name”:”Energy Saving”,”normalizedValue”:”High efficiency economy mode operation; Schedulable daily hours of economy mode operation”,”value”:”High efficiency economy mode operation; Schedulable daily hours of economy mode operation”},{“name”:”Replaceable Battery”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”12 min 30 sec”,”value”:”12.50 Minute”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Name”,”normalizedValue”:”SmartOnline SU10000RT3UG 10kVA Tower/Rack-mountable UPS”,”value”:”SmartOnline SU10000RT3UG 10kVA Tower/Rack-mountable UPS”},{“name”:”Surge Energy Rating”,”normalizedValue”:”2565 J”,”value”:”2565 J”},{“name”:”Product Line”,”normalizedValue”:”SmartOnline”,”value”:”SmartOnline”},{“name”:”Status Indicators”,”normalizedValue”:”LEDs: Line power, Online mode, Economy/bypass mode, On-battery, Charger, AC output”,”value”:”LEDs: Line power, Online mode, Economy/bypass mode, On-battery, Charger, AC output”},{“name”:”Maximum Operating Elevation”,”normalizedValue”:”9,842.52 ft”,”value”:”9842.52 ft”},{“name”:”EPO Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Waveform Type”,”normalizedValue”:”Pure Sine Wave”,”value”:”Pure Sine Wave”},{“name”:”Receptacle Detail”,”normalizedValue”:”6 x IEC 60320 C19″,”value”:”6 x IEC 60320 C19″},{“name”:”Load Capacity”,”normalizedValue”:”10000 VA”,”value”:”10000 VA”},{“name”:”Sound Emission (A-Weighted)”,”normalizedValue”:”60 dB”,”value”:”60 dB(A)”},{“name”:”DC System Voltage”,”normalizedValue”:”240 V DC”,”value”:”240 V DC”},{“name”:”USB (HID Compliant) Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Type”,”normalizedValue”:”Double Conversion Online UPS”,”value”:”Double Conversion Online UPS”},{“name”:”Power Cord Length”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Plug Configuration”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Number of Outlets – UPS”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 hr”},{“name”:”Power Rating – Real”,”normalizedValue”:”9 kW”,”value”:”9 kW”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Run Time – Half Load”,”normalizedValue”:”12 min 30 sec”,”value”:”12.5 min”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”2,565 J”,”value”:”2,565 J”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Receptacle Configuration”,”normalizedValue”:”C19″,”value”:”C19″},{“name”:”Overall Depth”,”normalizedValue”:”25.83 in”,”value”:”25.83 in”},{“name”:”Input Current – Maximum”,”normalizedValue”:”56.1 A”,”value”:”56.1 A”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP240V10RT3U, BP240V787C-1PH”,”value”:”BP240V10RT3U, BP240V787C-1PH”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Run Time – Full Load”,”normalizedValue”:”4 min 18 sec”,”value”:”4.3 min”},{“name”:”Transfer Time – Maximum”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Power Rating – Apparent”,”normalizedValue”:”10 kVA”,”value”:”10 kVA”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 10 kVA, On-Line/Double Conversion, Out: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC”