Smart UPS, 3kVA, Line Interactive, Out: 120V AC In: 120V AC

$1467,99

UPS,SmartPro,NAFTA assembld,SMART3000NET

9999 in stock

SKU: GRG5177125 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”3 kVA”,”rank”:4,”value”:”3kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”2.4 kW”,”rank”:6,”value”:”2.4 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120V AC”,”rank”:8,”value”:”120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”23 min/7 min”,”rank”:9,”value”:”23 min/7 min”},{“name”:”Number of Outlets”,”normalizedValue”:”8″,”rank”:12,”value”:”8″},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Transfer Time”,”normalizedValue”:”4 ms”,”value”:”4 ms”},{“name”:”Standards”,”normalizedValue”:”UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico)”,”value”:”UL1778 (USA), cUL (Canada), FCC Class A (emissions), NOM (Mexico)”},{“name”:”Width”,”normalizedValue”:”12-1/2 in”,”value”:”12.5 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R; 5-15/20R”,”value”:”(4) 5-15R; (4) 5-15/20R”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”Depth”,”normalizedValue”:”12-1/2 in”,”value”:”12.5 in”},{“name”:”Height”,”normalizedValue”:”17 in”,”value”:”17 in”},{“name”:”Input Current”,”normalizedValue”:”22 A”,”value”:”22 A”},{“name”:”Housing Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro SM3000NAFTA 3000VA Tower UPS, SMART3000NET UPS System, PowerAlert Software and three 6 foot network cables, Warranty information, Instruction manual”,”value”:”SmartPro SM3000NAFTA 3000VA Tower UPS, SMART3000NET UPS System, PowerAlert Software and three 6 foot network cables, Warranty information, Instruction manual”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Load Capacity”,”normalizedValue”:”3000 VA/2400 W”,”value”:”3000 VA/2400 W”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert UPS Monitoring Software”,”value”:”PowerAlert UPS Monitoring Software”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Additional Information”,”normalizedValue”:”Line Mode: Sine wave line voltage 120V (-13% / +5%), Battery Mode: PWM sine wave output 120V +/-5%”,”value”:”Line Mode: Sine wave line voltage 120V (-13% / +5%), Battery Mode: PWM sine wave output 120V +/-5%”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”30A 120V”,”value”:”30A 120V”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140″},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 87 and 94 are boosted by 22%”,”value”:”Input voltages between 87 and 94 are boosted by 22%”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)”,”value”:”BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Three switchable single-outlet 5-15R load banks”,”value”:”Three switchable single-outlet 5-15R load banks”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”17 x 9 x 12.5″,”value”:”17 x 9 x 12.5″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”22 A”,”value”:”22A”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”Communications Cable”,”normalizedValue”:”3 DB9 cables included”,”value”:”3 DB9 cables included”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 127 and 140 are reduced by 12%”,”value”:”Input voltages between 127 and 140 are reduced by 12%”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; contact closure communications via two additional DB9 ports (3 total)”,”value”:”Supports detailed monitoring of UPS and site power conditions; contact closure communications via two additional DB9 ports (3 total)”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”432″,”value”:”432″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”15A branch rated (x2) – each breaker protects 4 outlets”,”value”:”15A branch rated (x2) – each breaker protects 4 outlets”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”480″,”value”:”480″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”82.4″,”value”:”82.4″},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”1,219.3″,”value”:”1219.3″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”87″,”value”:”87″},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V”,”value”:”120V”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control system enable and contact closure port inverter shutoff commands”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control system enable and contact closure port inverter shutoff commands”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”2,400″,”value”:”2400″},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-13%, +5%”,”value”:”-13% / +5%”},{“name”:”Package Includes”,”normalizedValue”:”SMART3000NET UPS System;PowerAlert Software and three 6 foot network cables;Warranty information;Instruction manual”,”value”:”SMART3000NET UPS System;PowerAlert Software and three 6 foot network cables;Warranty information;Instruction manual”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 9 hours from 10% to 90%”,”value”:”Less than 9 hours from 10% to 90%”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”318″,”value”:”318″},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”8″,”value”:”8″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”140″,”value”:”140″},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”Communications Interface”,”normalizedValue”:”DB9 Serial; Contact closure”,”value”:”DB9 Serial; Contact closure”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Power Factor”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 95 and 105 are boosted by 10%”,”value”:”Input voltages between 95 and 105 are boosted by 10%”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Smart UPS, 3kVA, Line Interactive, Out: 120V AC In: 120V AC”