Description
[{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Double Conversion, On-Line”,”rank”:3,”value”:”On-Line/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”1.5 kVA”,”rank”:4,”value”:”1.5kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Rack”,”rank”:5,”value”:”Rack/Tower”},{“name”:”Wattage”,”normalizedValue”:”1.2 kW”,”rank”:6,”value”:”1.2 kW”},{“name”:”Input Voltage”,”normalizedValue”:”100/110/120VAC”,”rank”:7,”value”:”100/110/120VAC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/120VAC”,”rank”:8,”value”:”100/110/120VAC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”14 min/5 min”,”rank”:9,”value”:”14 min/5 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Phase”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Depth”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15p”},{“name”:”Input Current”,”normalizedValue”:”12 A”,”value”:”12 A”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”100V AC, 110V AC, 120V AC”,”value”:”100V AC, 110V AC, 120V AC”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”100V AC, 110V AC, 120V AC”,”value”:”100V AC, 110V AC, 120V AC”},{“name”:”Width”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Special Features”,”normalizedValue”:”True Online Protection with Pure Sine Wave Output, Extended Runtime Option with BP48V24-2U, BP48V60RT-3U, Use in Economy-Mode Saves Operating Costs,”,”value”:”True Online Protection with Pure Sine Wave Output, Extended Runtime Option with BP48V24-2U, BP48V60RT-3U, Use in Economy-Mode Saves Operating Costs,”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack, Tower”,”value”:”Rack/Tower”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”1.2 kW”,”value”:”1.2 kW”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1.5 kVA”,”value”:”1.5 kVA”},{“name”:”Standards”,”normalizedValue”:”CSA, FCC Part 15 Category A, NOM, UL 1778″,”value”:”CSA, FCC Part 15 Category A, NOM, UL 1778″},{“name”:”Ports”,”normalizedValue”:”Contact Closure, DB9 Serial, EPO, RS232, SNMP/Web Slot, USB (HID Enabled)”,”value”:”Contact Closure, DB9 Serial, EPO, RS232, SNMP/Web Slot, USB (HID Enabled)”},{“name”:”Watts”,”normalizedValue”:”1,200″,”value”:”1.2kW”},{“name”:”Footnotes”,”normalizedValue”:”3,4,6,7,8″,”value”:”3,4,6,7,8″},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Includes”,”normalizedValue”:”1 x 6 ft DB9 Cable, 1 x 6 ft USB Cable, 4-Post Rack Mounting Hardware, PowerAlert Software CD”,”value”:”1 x 6 ft DB9 Cable, 1 x 6 ft USB Cable, 4-Post Rack Mounting Hardware, PowerAlert Software CD”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”value”:”UPS/Surge”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Voltage”,”normalizedValue”:”100/110/120″,”value”:”100/110/120″},{“name”:”Input Connection”,”normalizedValue”:”10 ft Cord with NEMA 5-15P Plug”,”value”:”10 ft Cord with NEMA 5-15P Plug”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”600″,”value”:”600″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”612″,”value”:”612″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”100 V, 110 V, 120 V”,”value”:”100V; 110V; 120V”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Hot swappable batteries”,”value”:”Automatic inverter bypass; Hot swappable batteries”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Power Factor”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Sine wave”,”value”:”Sine wave”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output Capacity Details”,”normalizedValue”:”OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”,”value”:”OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 150″,”value”:”2% output voltage regulation during overvoltages to 150″},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 80″,”value”:”2% output voltage regulation during undervoltages to 80″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”,”value”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”20A”,”value”:”20A”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.5 x 17.5 x 19″,”value”:”3.5 x 17.5 x 19″},{“name”:”Input Frequency”,”normalizedValue”:”50/60Hz +/-5%”,”value”:”50/60Hz +/-5%”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Frequency Compatibility”,”normalizedValue”:”50 / 60 Hz”,”value”:”50 / 60 Hz”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Output Receptacles”,”normalizedValue”:”5-15R”,”value”:”(6) 5-15R”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”LED Indicators”,”normalizedValue”:”14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats”,”value”:”14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”483″,”value”:”483″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”14 min”,”value”:”14 min. (600w)”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 65 (under 70% load only)”,”value”:”2% output voltage regulation during undervoltages to 65 (under 70% load only)”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,200″,”value”:”1200″},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”22″,”value”:”22″},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”100 V AC, 110 V AC, 120 V AC”,”value”:”100V AC; 110V AC; 120V AC”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”1.2″,”value”:”1.2″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”80V (100% load), 65V ( \u003c70% load)”,”value”:”80V (100% load), 65V ( \u003c70% load)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start”,”value”:”Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”12A”,”value”:”12A”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 6 hours from 10% to 80% (typical, full load discharge)”,”value”:”Less than 6 hours from 10% to 80% (typical, full load discharge)”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.95″,”value”:”0.95″},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1.5″,”value”:”1.5″},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”667″,”value”:”667″},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable 5-15R load banks (bank 1 – two outlets, bank 2 – four outlets)”,”value”:”Two switchable 5-15R load banks (bank 1 – two outlets, bank 2 – four outlets)”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC94-2U”,”value”:”RBC94-2U”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”5 min”,”value”:”5 min. (1200w)”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”216″,”value”:”216″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”120V default”,”value”:”120V default”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”,”value”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”26″,”value”:”26″},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”445″,”value”:”445″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Dataline Protection”,”normalizedValue”:”RJ-45″,”value”:”RJ-45″},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”5 Minute”,”value”:”5 Minute”},{“name”:”Product Name”,”normalizedValue”:”SmartOnline SU1500RTXL2Ua 1500VA Tower/Rack-mountable UPS”,”value”:”SmartOnline SU1500RTXL2Ua 1500VA Tower/Rack-mountable UPS”},{“name”:”Additional Information”,”normalizedValue”:”SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications, Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time, Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types”,”value”:”SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications, Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time, Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Package Contents”,”normalizedValue”:”SMART ONLINE UPS 1500VA XL RM 2U TWR 120V 5-15P 6OUT USB SER SLOT, SU1500RTXL2Ua Online Double-Conversion UPS System, PowerAlert Software and cabling, Mounting hardware for 4 post rack enclosures, Instruction manual with warranty information”,”value”:”SMART ONLINE UPS 1500VA XL RM 2U TWR 120V 5-15P 6OUT USB SER SLOT, SU1500RTXL2Ua Online Double-Conversion UPS System, PowerAlert Software and cabling, Mounting hardware for 4 post rack enclosures, Instruction manual with warranty information”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Receptacle Detail”,”normalizedValue”:”6 x NEMA 5-15R”,”value”:”6 x NEMA 5-15R”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”5 hr”,”value”:”5 Hour”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”14 min”,”value”:”14 Minute”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Plug/Connector Type”,”normalizedValue”:”NEMA 5-15P”,”value”:”NEMA 5-15P”},{“name”:”Product Type”,”normalizedValue”:”Double Conversion Online UPS”,”value”:”Double Conversion Online UPS”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Product Line”,”normalizedValue”:”SmartOnline”,”value”:”SmartOnline”},{“name”:”Load Capacity”,”normalizedValue”:”1500 VA/1200 W”,”value”:”1500 VA/1200 W”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.