Smart UPS, 1.5kVA, Line Interactive, Out: 110/115/120V AC In: 110/115/120V AC

$543,99

Smart UPS, Line Interactive, Power Rating 1.5 kVA, Wattage 900 W, Input Voltage 120V AC, Output Voltage 115V AC, 120V AC, Backup Time (Half/Full Load) 12 min/4 min, Mounting Rack/Tower, Outlet Type UPS/Surge, Number of Outlets 8, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation Yes, Fax/Modem Line Protection Yes, Transfer Time 3 msec from Battery to AC, 4 msec from AC to Battery, Width 17 in, Depth 11 in

9999 in stock

SKU: GRG4258895 Category:

Description

[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1.5 kVA”,”rank”:2,”value”:”1.5 kVA”},{“name”:”Item”,”normalizedValue”:”Smart UPS”,”rank”:2,”value”:”Smart UPS”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1.5 kVA”,”rank”:4,”value”:”1.5kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Rack”,”rank”:5,”value”:”Rack/Tower”},{“name”:”Wattage”,”normalizedValue”:”900 W”,”rank”:6,”value”:”900 W”},{“name”:”Input Voltage”,”normalizedValue”:”110/115/120V AC”,”rank”:7,”value”:”110/115/120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V AC”,”rank”:8,”value”:”110/115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”12 min/4.18 min”,”rank”:9,”value”:”12 min/4.18 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”8″,”rank”:12,”value”:”8″},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(8) 5-15R”},{“name”:”Depth”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Footnotes”,”normalizedValue”:”3,4,6″,”value”:”3,4,6″},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class B (USA), NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class B (USA), NOM (Mexico), RoHS, UL1778″},{“name”:”Transfer Time”,”normalizedValue”:”3 msec from Battery to AC, 4 msec from AC to Battery”,”value”:”3 msec from Battery to AC, 4 msec from AC to Battery”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Ports”,”normalizedValue”:”Contact Closure, DB9 Serial, USB (HID Enabled)”,”value”:”Contact Closure, DB9 Serial, USB (HID Enabled)”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Current”,”normalizedValue”:”8.5 A”,”value”:”8.5 A”},{“name”:”Includes”,”normalizedValue”:”DB9 Serial Cable, Mounting Hardware, SMART1500LCDXL SmartProLCD 120V 1500VA/900W Line-Interactive UPS, Telephone Cable, USB Cables”,”value”:”DB9 Serial Cable, Mounting Hardware, SMART1500LCDXL SmartProLCD 120V 1500VA/900W Line-Interactive UPS, Telephone Cable, USB Cables”},{“name”:”Special Features”,”normalizedValue”:”Automatic Voltage Regulation”,”value”:”Automatic Voltage Regulation”},{“name”:”Width”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”Overall Height”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Overall Width”,”normalizedValue”:”17.3 in”,”value”:”17.3 in”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Capacity – Batteries”,”normalizedValue”:”1500 VA/900 W”,”value”:”1500 VA/900 W”},{“name”:”Input Connection”,”normalizedValue”:”6 ft Cord with NEMA 5-15P Plug”,”value”:”6 ft Cord with NEMA 5-15P Plug”},{“name”:”Housing Material”,”normalizedValue”:”Polycarbonate”,”value”:”Polycarbonate”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 Serial cabling included”,”value”:”USB and DB9 Serial cabling included”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placement installation”,”value”:”Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placement installation”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery pack (limit 1)”,”value”:”Extended runtime supported via optional external battery pack (limit 1)”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”267″,”value”:”267″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4.5 hours from 10% to 90%”,”value”:”Less than 4.5 hours from 10% to 90%”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery conditions; Alarm can be permanently silenced via LCD interface”,”value”:”Audible alarm indicates power-failure and low-battery conditions; Alarm can be permanently silenced via LCD interface”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 93 and 107 are boosted by 14%”,”value”:”Input voltages between 93 and 107 are boosted by 14%”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”78″,”value”:”78″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”13.5″,”value”:”13.5″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”See RBC Selector for replacement battery information”,”value”:”See RBC Selector for replacement battery information”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure”,”value”:”USB (HID enabled); DB9 Serial; Contact closure”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”110 V AC, 115 V AC, 120 V AC”,”value”:”110V AC; 115V AC; 120V AC”},{“name”:”Relative Humidity”,”normalizedValue”:”Up to 95%, non-condensing”,”value”:”Up to 95%, non-condensing”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1.5″,”value”:”1.5″},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.5 x 17.3 x 10.5″,”value”:”3.5 x 17.3 x 10.5″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”147″,”value”:”147″},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”721″,”value”:”721″},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 128 and 147 are reduced by 12%”,”value”:”Input voltages between 128 and 147 are reduced by 12%”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door enables hot-swappable, user replaceable internal battery”,”value”:”Battery access door enables hot-swappable, user replaceable internal battery”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”1,038″,”value”:”1038″},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 75 and 92 are boosted by 30%”,”value”:”Input voltages between 75 and 92 are boosted by 30%”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min”,”value”:”12 min. (450w)”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”8.6 A”,”value”:”8.6A”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”75″,”value”:”75″},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP24V15RT2U (limit 1)”,”value”:”BP24V15RT2U (limit 1)”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”LCD interface reports Input Voltage, Output Voltage, Battery Charge Percentage, Estimated Runtime in Minutes, Load Percentage, Load Watts; Additional LCD icons report battery charge level (5 \”bars\”), Line Power Mode, Battery Mode, Replace Battery and Auto-Voltage Regulation / AVR status; LCD interface control options include Alarm Disable, Display Scrolling, Initiate Self-test, LCD brightness, External Battery setting and line sensitivity”,”value”:”LCD interface reports Input Voltage, Output Voltage, Battery Charge Percentage, Estimated Runtime in Minutes, Load Percentage, Load Watts; Additional LCD icons report battery charge level (5 \”bars\”), Line Power Mode, Battery Mode, Replace Battery and Auto-Voltage Regulation / AVR status; LCD interface control options include Alarm Disable, Display Scrolling, Initiate Self-test, LCD brightness, External Battery setting and line sensitivity”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-18%, +8%”,”value”:”-18%, +8%”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”13.5″,”value”:”13.5″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port also supports contact-closure messaging for power-fail (pins 1 \u0026 9) and power-restored (pins 1, 8)”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port also supports contact-closure messaging for power-fail (pins 1 \u0026 9) and power-restored (pins 1, 8)”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”2 post 19 inch rackmount; 4 post 19 inch rackmount; Tower”,”value”:”2 post 19 inch rackmount; 4 post 19 inch rackmount; Tower”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min”,”value”:”4 min. (900w)”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Load Capacity”,”normalizedValue”:”1500 VA/900 W”,”value”:”1500 VA/900 W”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Package Contents”,”normalizedValue”:”Smart LCD SMART1500LCDXL 1500 VA Tower/Rack Mountable UPS, USB Cable, Serial Cable, Phone Cable, Rack/Tower Mounting Kit, Owner’s Manual”,”value”:”Smart LCD SMART1500LCDXL 1500 VA Tower/Rack Mountable UPS, USB Cable, Serial Cable, Phone Cable, Rack/Tower Mounting Kit, Owner’s Manual”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.50 Hour”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”3.5 x 17.25 x 10.5″,”value”:”3.500 x 17.250 x 10.500″},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”6562″,”value”:”6562″},{“name”:”Power Factor”,”normalizedValue”:”0.6″,”value”:”0.6″},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”14″,”value”:”14″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”,”value”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”},{“name”:”UPS Applications”,”normalizedValue”:”Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”,”value”:”Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”Package Includes”,”normalizedValue”:”SMART1500LCDXL SmartPro LCD 120V 1500VA/900W Line-Interactive UPS;USB cable;DB9 serial cable;Telephone cable;Mounting hardware;Owner’s Manual”,”value”:”SMART1500LCDXL SmartPro LCD 120V 1500VA/900W Line-Interactive UPS;USB cable;DB9 serial cable;Telephone cable;Mounting hardware;Owner’s Manual”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Input Current – Maximum”,”normalizedValue”:”8.6 A”,”value”:”8.6 A”},{“name”:”Power Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP24V15RT2U”,”value”:”BP24V15RT2U”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Output Ports Included”,”normalizedValue”:”Contact Closure, DB9 Serial, USB”,”value”:”Contact Closure, DB9 Serial, USB”},{“name”:”Power Rating – Real”,”normalizedValue”:”900 W”,”value”:”900 W”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”1,038 J”,”value”:”1,038 J”},{“name”:”Overall Depth”,”normalizedValue”:”10-1/2 in”,”value”:”10.5 in”},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.5 hr”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Power Outage”,”value”:”Low Battery, Power Outage”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Smart UPS, 1.5kVA, Line Interactive, Out: 110/115/120V AC In: 110/115/120V AC”