Description
[{“name”:”Height”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Width”,”normalizedValue”:”3.1 in”,”value”:”3.1 in”},{“name”:”Depth”,”normalizedValue”:”4.7 in”,”value”:”4.7 in”},{“name”:”Product Name”,”normalizedValue”:”S-1000MM-M2ST2 – Gigabit Ethernet Fiber to Fiber Stand-Alone Media Converter”,”value”:”S-1000MM-M2ST2 – Gigabit Ethernet Fiber to Fiber Stand-Alone Media Converter”},{“name”:”Fiber Mode Supported”,”normalizedValue”:”Multi-mode”,”value”:”Multi-mode”},{“name”:”Weight (Approximate)”,”normalizedValue”:”10.56 oz”,”value”:”10.56 oz”},{“name”:”Form Factor”,”normalizedValue”:”Desktop, Wall Mountable, Rail-mountable, Rack-mountable”,”value”:”Desktop, Wall Mountable, Rail-mountable, Rack-mountable”},{“name”:”Package Contents”,”normalizedValue”:”S-1000MM-M2ST2 – Gigabit Ethernet Fiber to Fiber Stand-Alone Media Converter, Universal DC Adapter”,”value”:”S-1000MM-M2ST2 – Gigabit Ethernet Fiber to Fiber Stand-Alone Media Converter, Universal DC Adapter”},{“name”:”Maximum Distance Supported”,”normalizedValue”:”1.24 mi”,”value”:”1.24 Mile”},{“name”:”Fiber Optic Cable Standard”,”normalizedValue”:”50/125 µm, 62.5/125 µm”,”value”:”50/125 µm, 62.5/125 µm”},{“name”:”Input voltage”,”normalizedValue”:”30 V DC”,”value”:”30 V DC”},{“name”:”Number of ST Ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Total Number of Ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Network Technology”,”normalizedValue”:”1000Base-SX, 1000Base-LX”,”value”:”1000Base-SX, 1000Base-LX”},{“name”:”Media Type Supported”,”normalizedValue”:”Optical Fiber”,”value”:”Optical Fiber”},{“name”:”Product Type”,”normalizedValue”:”Transceiver/Media Converter”,”value”:”Transceiver/Media Converter”},{“name”:”Certifications \u0026 Standards”,”normalizedValue”:”Immunity: EN55024, IEEE Standards: IEEE 802.3,IEEE 802.3u,IEEE 802.3ab,IEEE 802.3x Emissions: FCC Part 15 Class A, EN55022 Class A,EN61000-3-2,CISPR 22 Class A Electrical Safety: EN60950,UL 60950-1,CE Laser Safety: EN 60825-1:2007,Class 1 Laser Safety Requirements per IEC-60825 FDA/CDRH Standards,21CFR1040.10,21CFR1040.11 Others: ECCN: 5A991A,HTSUS Number: 8517.62.0050″,”value”:”Immunity: EN55024, IEEE Standards: IEEE 802.3,IEEE 802.3u,IEEE 802.3ab,IEEE 802.3x Emissions: FCC Part 15 Class A, EN55022 Class A,EN61000-3-2,CISPR 22 Class A Electrical Safety: EN60950,UL 60950-1,CE Laser Safety: EN 60825-1:2007,Class 1 Laser Safety Requirements per IEC-60825 FDA/CDRH Standards,21CFR1040.10,21CFR1040.11 Others: ECCN: 5A991A,HTSUS Number: 8517.62.0050″},{“name”:”ST Port Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Environmentally Friendly”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Remote Loopback #1″,”normalizedValue”:”The media converter can perform a loopback on the link #1 fiber interface; Disabled (Default – Up); Enabled- The 1000Base-X receiver is looped to the 1000Base-X transmitter. Link #2’s fiber transmitter is taken off the interface”,”value”:”The media converter can perform a loopback on the link #1 fiber interface; Disabled (Default – Up); Enabled- The 1000Base-X receiver is looped to the 1000Base-X transmitter. Link #2’s fiber transmitter is taken off the interface”},{“name”:”Dimensions”,”normalizedValue”:”120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches”,”value”:”120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches”},{“name”:”Fiber Fault Alert”,”normalizedValue”:”Enabled – (default up)- If the media converter detects a loss of fiber signal on a fiber receiver, it will immediately disable its fiber transmitter signal. This, in effect, notifies the remote fiber link partner that an error condition exists on the fiber connection. The setting of this switch applies to both fiber ports; Disabled: The media converter will not monitor for fiber fault or generate them.”,”value”:”Enabled – (default up)- If the media converter detects a loss of fiber signal on a fiber receiver, it will immediately disable its fiber transmitter signal. This, in effect, notifies the remote fiber link partner that an error condition exists on the fiber connection. The setting of this switch applies to both fiber ports; Disabled: The media converter will not monitor for fiber fault or generate them.”},{“name”:”Storage Humidity”,”normalizedValue”:”5% to 95% non-condensing”,”value”:”5% to 95% non-condensing”},{“name”:”Power Connector”,”normalizedValue”:”5.5mm x 9.5mm x 2.1mm barrel socket”,”value”:”5.5mm x 9.5mm x 2.1mm barrel socket”},{“name”:”Current”,”normalizedValue”:”0.21 amps”,”value”:”0.21 amps”},{“name”:”Laser Safety”,”normalizedValue”:”EN 60825-1:2007″,”value”:”EN 60825-1:2007″},{“name”:”Storage temperature”,”normalizedValue”:”minimum range of -25° C to 70° C (-13° F to 158° F)”,”value”:”minimum range of -25° C to 70° C (-13° F to 158° F)”},{“name”:”Operating Humidity”,”normalizedValue”:”5% to 90% non-condensing”,”value”:”5% to 90% non-condensing”},{“name”:”Bit Error Rate (BER)”,”normalizedValue”:”\u003c10-12″,”value”:”\u003c10-12″},{“name”:”Emissions”,”normalizedValue”:”FCC Part 15 Class A, EN55022 Class A”,”value”:”FCC Part 15 Class A, EN55022 Class A”},{“name”:”Universal AC/DC adapter”,”normalizedValue”:”100-240v AC, regulated DC adapter included”,”value”:”100-240v AC, regulated DC adapter included”},{“name”:”Operating temperature”,”normalizedValue”:”0° C to 50° C (32° F to 122° F)”,”value”:”0° C to 50° C (32° F to 122° F)”},{“name”:”Fiber link 1 / Receive activity (LK1)”,”normalizedValue”:”This green LED is operational only when power is applied. The LED is on when the 100Base-X link is on and flashes with a 50% duty cycle when data is received.”,”value”:”This green LED is operational only when power is applied. The LED is on when the 100Base-X link is on and flashes with a 50% duty cycle when data is received.”},{“name”:”1000Base-X”,”normalizedValue”:”Multimode dual ST [ 550 m/1804 ft ] to multimode dual ST fiber connector model; Available in SC, ST and LC connector models”,”value”:”Multimode dual ST [ 550 m/1804 ft ] to multimode dual ST fiber connector model; Available in SC, ST and LC connector models”},{“name”:”Power / TST”,”normalizedValue”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink slowly when in Loopback test mode.”,”value”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink slowly when in Loopback test mode.”},{“name”:”Operating Altitude”,”normalizedValue”:”Up to 3,048 meters (10,000 feet)”,”value”:”Up to 3,048 meters (10,000 feet)”},{“name”:”Fiber link 2 on / Receive activity (LK2)”,”normalizedValue”:”This green LED is operational only when power is applied. The LED is on when the 100Base-X link is on and flashes with a 50% duty cycle when data is received.”,”value”:”This green LED is operational only when power is applied. The LED is on when the 100Base-X link is on and flashes with a 50% duty cycle when data is received.”},{“name”:”Auto-Negotiation”,”normalizedValue”:”Auto (default up)- Fiber Negotiation is performed for both fiber ports. Full and half duplex will be advertised. Pause will advertise support for Symmetrical and Asymmetrical Pause. Pause frame will not be acted upon or generated but will be passed through; Off- Negotiation on both fiber ports will be disabled. Settings of Link mode and Fiber fault alert will be determined by those switch settings. Pause frames will not be acted upon or generated but will continue to be passed through.”,”value”:”Auto (default up)- Fiber Negotiation is performed for both fiber ports. Full and half duplex will be advertised. Pause will advertise support for Symmetrical and Asymmetrical Pause. Pause frame will not be acted upon or generated but will be passed through; Off- Negotiation on both fiber ports will be disabled. Settings of Link mode and Fiber fault alert will be determined by those switch settings. Pause frames will not be acted upon or generated but will continue to be passed through.”},{“name”:”Remote Loopback #2″,”normalizedValue”:”The media converter can perform a loopback on the link #2 fiber interface; Disabled ; Enabled- The 1000Base-X receiver is looped to the 1000Base-X transmitter. Link #1’s fiber transmitter is taken off the interface”,”value”:”The media converter can perform a loopback on the link #2 fiber interface; Disabled (Default – Up); Enabled- The 1000Base-X receiver is looped to the 1000Base-X transmitter. Link #1’s fiber transmitter is taken off the interface”},{“name”:”Heat Output ( BTU/HR )”,”normalizedValue”:”8.53″,”value”:”8.53″},{“name”:”Input Supply Voltage”,”normalizedValue”:”6 – 30 vDC, unregulated ( 12 vDC Nominal )”,”value”:”6 – 30 vDC, unregulated ( 12 vDC Nominal )”},{“name”:”Power Consumption”,”normalizedValue”:”2.5 watts”,”value”:”2.5 watts”},{“name”:”Immunity”,”normalizedValue”:”EN55024″,”value”:”EN55024″},{“name”:”Electrical Safety”,”normalizedValue”:”UL 60950-1″,”value”:”UL 60950-1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Canada”,”value”:”Canada”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.