S-1000-S1Sc40D Media Converter

$2153,99

S-1000-S1SC40D – Gigabit Media Converter: 1000BASE-T (RJ-45) [100 m/328 ft.] to 1000BASE-BX 1490nm TX / 1310nm RX single strand fiber, single mode (SC) [40 km/25 miles] – USA Power Cord

9999 in stock

SKU: GRG4395425 Category:

Description

[{“name”:”Depth”,”normalizedValue”:”3.1 in”,”value”:”3.1 in”},{“name”:”Height”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Width”,”normalizedValue”:”4.7 in”,”value”:”4.7 in”},{“name”:”Maximum Distance Supported”,”normalizedValue”:”24.85 mi”,”value”:”24.85 Mile”},{“name”:”Package Contents”,”normalizedValue”:”S-1000-S1SC40D Media Converter, 100-240v AC, Regulated DC Adapter”,”value”:”S-1000-S1SC40D Media Converter, 100-240v AC, Regulated DC Adapter”},{“name”:”Number of Network (RJ-45) Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Number of SC Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Product Name”,”normalizedValue”:”S-1000-S1SC40D Media Converter”,”value”:”S-1000-S1SC40D Media Converter”},{“name”:”Network (RJ-45)”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Type”,”normalizedValue”:”Transceiver/Media Converter”,”value”:”Transceiver/Media Converter”},{“name”:”Network Technology”,”normalizedValue”:”1000Base-BX, 10/100/1000Base-T”,”value”:”1000Base-BX, 10/100/1000Base-T”},{“name”:”Total Number of Ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Form Factor”,”normalizedValue”:”Wall Mountable, Rack-mountable, Rail-mountable”,”value”:”Wall Mountable, Rack-mountable, Rail-mountable”},{“name”:”Weight (Approximate)”,”normalizedValue”:”1.10 lb”,”value”:”1.10 lb”},{“name”:”Environmentally Friendly”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Copper link on / Receive activity (LKC)”,”normalizedValue”:”This green LED is operational only when power is applied. The LED i on when the 1000Base-T link is on and flashes with a 50% duty cycle when data is received. The LED will slow blink when the 1000Base-T interface has been taken down as a result of a fault on the 1000Base-T interface.”,”value”:”This green LED is operational only when power is applied. The LED i on when the 1000Base-T link is on and flashes with a 50% duty cycle when data is received. The LED will slow blink when the 1000Base-T interface has been taken down as a result of a fault on the 1000Base-T interface.”},{“name”:”Input Supply Voltage”,”normalizedValue”:”6 – 30 vDC, unregulated ( 12 vDC Nominal )”,”value”:”6 – 30 vDC, unregulated ( 12 vDC Nominal )”},{“name”:”Immunity”,”normalizedValue”:”EN55024″,”value”:”EN55024″},{“name”:”Duplex”,”normalizedValue”:”AUTO -The Media converter will advertise Full Duplex Not Capable, Half Duplex Capable., Full – The media converter will advertise Full Duplex Capable, Half Duplex Capable”,”value”:”Full (Default-Up)- The media converter will advertise Full Duplex Capable, Half Duplex Capable; AUTO (Down)-The Media converter will advertise Full Duplex Not Capable, Half Duplex Capable.”},{“name”:”Operating Altitude”,”normalizedValue”:”Up to 3,048 meters (10,000 feet)”,”value”:”Up to 3,048 meters (10,000 feet)”},{“name”:”Power / TST”,”normalizedValue”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink when in Loopback test mode.”,”value”:”This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink when in Loopback test mode.”},{“name”:”Laser Safety”,”normalizedValue”:”EN 60825-1:2007″,”value”:”EN 60825-1:2007″},{“name”:”Electrical Safety”,”normalizedValue”:”UL 60950-1″,”value”:”UL 60950-1″},{“name”:”Auto-Negotiation”,”normalizedValue”:”Enabled (Default – Up)- In this mode the 1000Base-X and the 1000Base-T will negotiate to the HCD of the two link partners. The 1000Base-X will link up after the negotiation is completed and the 1000Base-T has linked up; Disabled- The 1000Base-X will not use auto negotiation. The 1000Base-T will negotiate to the HCD of the Switch settings and the link partner.”,”value”:”Enabled (Default – Up)- In this mode the 1000Base-X and the 1000Base-T will negotiate to the HCD of the two link partners. The 1000Base-X will link up after the negotiation is completed and the 1000Base-T has linked up; Disabled- The 1000Base-X will not use auto negotiation. The 1000Base-T will negotiate to the HCD of the Switch settings and the link partner.”},{“name”:”Bit Error Rate (BER)”,”normalizedValue”:”\u003c10-12″,”value”:”\u003c10-12″},{“name”:”Magnetic Isolation”,”normalizedValue”:”1.5kv”,”value”:”1.5kv”},{“name”:”Emissions”,”normalizedValue”:”FCC Part 15 Class A, EN55022 Class A”,”value”:”FCC Part 15 Class A, EN55022 Class A”},{“name”:”Power Consumption”,”normalizedValue”:”3.0 watts”,”value”:”3.0 watts”},{“name”:”Storage temperature”,”normalizedValue”:”minimum range of -25° C to 70° C (-13° F to 158° F)”,”value”:”minimum range of -25° C to 70° C (-13° F to 158° F)”},{“name”:”Dimentions”,”normalizedValue”:”120 mm x 80 mm x 26 mm, 4.7 in x 3.1 in x 1 in”,”value”:”120 x 80 x 26 mm, 4.7 x 3.1 x 1.0 inches”},{“name”:”Fiber Fault Alert”,”normalizedValue”:”The Fiber Fault Alert switch has meaning when Auto-Negotiation is disabled; Enabled (Default – Up); When the 1000Base-X receiver is off the 1000Base-X transmitter is turned off. Periodically the 1000Base-X receiver will be turned on for a short period to allow the condition to clear if the 1000Base-X link partner is using a similar feature; Disabled (Down)”,”value”:”The Fiber Fault Alert switch has meaning when Auto-Negotiation is disabled; Enabled (Default – Up); When the 1000Base-X receiver is off the 1000Base-X transmitter is turned off. Periodically the 1000Base-X receiver will be turned on for a short period to allow the condition to clear if the 1000Base-X link partner is using a similar feature; Disabled (Down)”},{“name”:”Operating Humidity”,”normalizedValue”:”5% to 90% non-condensing”,”value”:”5% to 90% non-condensing”},{“name”:”Universal AC/DC adapter”,”normalizedValue”:”100-240v AC, regulated DC adapter included”,”value”:”100-240v AC, regulated DC adapter included”},{“name”:”Storage Humidity”,”normalizedValue”:”5% to 95% non-condensing”,”value”:”5% to 95% non-condensing”},{“name”:”1000Base-T”,”normalizedValue”:”Single mode single SC Media Converter; RJ45 connector, 4 pair CAT 5 UTP cable or cable”,”value”:”Single mode single SC Media Converter; RJ45 connector, 4 pair CAT 5 UTP cable or cable”},{“name”:”Heat Output ( BTU/HR )”,”normalizedValue”:”10.2″,”value”:”10.2″},{“name”:”Current”,”normalizedValue”:”250 mA”,”value”:”250 mA”},{“name”:”Pause”,”normalizedValue”:”When Fiber Auto Negotiation is disabled Pause should only be enabled when all devices connected to the media converter support pause; Enabled(Default)- The Media converter will advertise Pause capable, Asymmetric pause not needed during Auto-Negotiation; Disabled- The Media converter will advertise that it does not have Pause capability during Auto-Negotiation.”,”value”:”When Fiber Auto Negotiation is disabled Pause should only be enabled when all devices connected to the media converter support pause; Enabled(Default)- The Media converter will advertise Pause capable, Asymmetric pause not needed during Auto-Negotiation; Disabled- The Media converter will advertise that it does not have Pause capability during Auto-Negotiation.”},{“name”:”Power Connector”,”normalizedValue”:”5.5mm x 9.5mm x 2.1mm barrel socket”,”value”:”5.5mm x 9.5mm x 2.1mm barrel socket”},{“name”:”Fiber link on / Receive activity (LKF)”,”normalizedValue”:”This green LED is operational only when power is applied. The LED is on when the 1000Base-X link is on and flashes with a 50% duty cycle when data is received. The LED will slow blink when the 1000Base-X interface has been taken down as a result of a fault on the 1000Base-T interface.”,”value”:”This green LED is operational only when power is applied. The LED is on when the 1000Base-X link is on and flashes with a 50% duty cycle when data is received. The LED will slow blink when the 1000Base-X interface has been taken down as a result of a fault on the 1000Base-T interface.”},{“name”:”Remote Loopback”,”normalizedValue”:”The media converter can perform a loopback on the 1000Base-X fiber interface; Disabled (Default – Up); Enabled- The 1000Base-X receiver is looped to the 1000Base-X transmitter. The 1000Base-T transmitter is taken off the interface.”,”value”:”The media converter can perform a loopback on the 1000Base-X fiber interface; Disabled (Default – Up); Enabled- The 1000Base-X receiver is looped to the 1000Base-X transmitter. The 1000Base-T transmitter is taken off the interface.”},{“name”:”Operating temperature”,”normalizedValue”:”0° C to 50° C (32° F to 122° F)”,”value”:”0° C to 50° C (32° F to 122° F)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Canada”,”value”:”Canada”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “S-1000-S1Sc40D Media Converter”