PUSH-IN TERMINAL, 20 A

$5,39

Push-In Terminal, Circuit Protection Type None, Connection Type Push-In, Current 20 A, For Minimum Wire Size 24 AWG, For Maximum Wire Size 12 AWG, Housing Color Gray, Maximum Voltage 300 V AC, Mounting Type Clip-On, Number of Poles 1, Number of Tiers 1, For Conductor Material Not Applicable, For Conductor Type Not Applicable, For Fuse Diameter 5 mm, 6 mm, For Fuse Length 32 mm, Overall Depth 36.5 mm, Overall Length 56 mm, Overall Width 6.2 mm, Standards CSA, cULus, EAC, GL, VDE

9999 in stock

SKU: GRG505907337 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Push-In Terminal”,”rank”:1,”value”:”Push-In Terminal”},{“name”:”Number of Poles”,”normalizedValue”:”1″,”rank”:9,”value”:”1″},{“name”:”Number of Connections”,”normalizedValue”:”2″,”rank”:10,”value”:”2″},{“name”:”Height”,”normalizedValue”:”36.5 mm”,”value”:”36.5 mm”},{“name”:”Standards”,”normalizedValue”:”CSA, cULus, EAC, GL, VDE”,”value”:”CSA, cULus, EAC, GL, VDE”},{“name”:”Material”,”normalizedValue”:”polyamide 6/6 insulating case”,”value”:”polyamide 6/6 insulating case”},{“name”:”Length”,”normalizedValue”:”56 mm”,”value”:”56 mm”},{“name”:”Width”,”normalizedValue”:”6.2 mm”,”value”:”6.2 mm”},{“name”:”Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Connection Type”,”normalizedValue”:”Push-In”,”value”:”Push-In”},{“name”:”Housing Material”,”normalizedValue”:”Polyamide 6/6″,”value”:”Polyamide 6/6″},{“name”:”Compatible with Product Type”,”normalizedValue”:”Special Enclosures”,”value”:”Special Enclosures”},{“name”:”Circuit Protection Type”,”normalizedValue”:””,”value”:”None”},{“name”:”Strip Length”,”normalizedValue”:”10 mm”,”value”:”10 mm”},{“name”:”Housing Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”UL 94 Flammability Rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Overall Width”,”normalizedValue”:”6.2 mm”,”value”:”6.2 mm”},{“name”:”Current”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Overall Length”,”normalizedValue”:”56 mm”,”value”:”56 mm”},{“name”:”For Fuse Diameter”,”normalizedValue”:”5 mm, 6 mm”,”value”:”5 mm, 6 mm”},{“name”:”Maximum Voltage”,”normalizedValue”:”300 V AC”,”value”:”300 V AC”},{“name”:”Number of Tiers”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”For Fuse Length”,”normalizedValue”:”32 mm”,”value”:”32 mm”},{“name”:”Terminal Block Type”,”normalizedValue”:”Disconnect”,”value”:”Removable Carrier Disconnect”},{“name”:”Overall Depth”,”normalizedValue”:”36.5 mm”,”value”:”36.5 mm”},{“name”:”RoHS Compliant”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”266 deg F”,”value”:”266 Degrees F”},{“name”:”For Minimum Wire Size”,”normalizedValue”:”24 AWG”,”value”:”24 AWG”},{“name”:”For Conductor Type”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”For Maximum Wire Size”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”For Conductor Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Number Of Measurement Input”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Product Or Component Type”,”normalizedValue”:”terminal block”,”value”:”terminal block”},{“name”:”Line Rated Current”,”normalizedValue”:”20-20 A EN/IEC 60947-7-1 || 20-20 A cURus || 20-20 A CSA”,”value”:”20-20 A EN/IEC 60947-7-1 || 20-20 A cURus || 20-20 A CSA”},{“name”:”Product Compatibility”,”normalizedValue”:”Spacial enclosures”,”value”:”Spacial enclosures”},{“name”:”Cable Cross Section”,”normalizedValue”:”0.2-4 mm², flexible without cable end || 0.2-6 mm², solid”,”value”:”0.2-4 mm², flexible without cable end || 0.2-6 mm², solid”},{“name”:”Wire Stripping Length”,”normalizedValue”:”10 mm”,”value”:”10 mm”},{“name”:”Fuse Size”,”normalizedValue”:”5 x 20 mm || 6 x 32 mm”,”value”:”5 x 20 mm || 6 x 32 mm”},{“name”:”Tool Type”,”normalizedValue”:”screwdriver”,”value”:”disconnection flat screwdriver || connection without tool”},{“name”:”Dielectric Loss”,”normalizedValue”:”0.01 at 1 MHz IEC 60250 || 0.01 at 1 MHz VDE 0303-T4″,”value”:”0.01 at 1 MHz IEC 60250 || 0.01 at 1 MHz VDE 0303-T4″},{“name”:”Dielectric Constant”,”normalizedValue”:”3.7 at 1 MHz”,”value”:”3.7 at 1 MHz”},{“name”:”Surface Resistance”,”normalizedValue”:”1000 GΩ IEC 60093 || 1000 GΩ VDE 0303-T30″,”value”:”1000 GΩ IEC 60093 || 1000 GΩ VDE 0303-T30″},{“name”:”Resistivity”,”normalizedValue”:”10000 MΩ.m IEC 60093 || 10000 MΩ.m VDE 0303-T30″,”value”:”10000 MΩ.m IEC 60093 || 10000 MΩ.m VDE 0303-T30″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-130°C IEC 60216-1 || -40-130°C VDE 0304-T21″,”value”:”-40-130°C IEC 60216-1 || -40-130°C VDE 0304-T21″},{“name”:”Creep Resistance”,”normalizedValue”:”500 CTI (\u003e 400 kB) IEC 60093 || 500 CTI (\u003e 400 kB) VDE 0303-T30″,”value”:”500 CTI (\u003e 400 kB) IEC 60093 || 500 CTI (\u003e 400 kB) VDE 0303-T30″},{“name”:”Dielectric Strength”,”normalizedValue”:”1000 V IEC 60243-1″,”value”:”1000 V IEC 60243-1″},{“name”:”Device Short Name”,”normalizedValue”:”TRP”,”value”:”TRP”},{“name”:”Nominal Cross Section”,”normalizedValue”:”4 mm²”,”value”:”4 mm²”},{“name”:”Associated Connection Component”,”normalizedValue”:”diode || cylindrical fuse || blade”,”value”:”diode || cylindrical fuse || blade”},{“name”:”Mounting Mode”,”normalizedValue”:”clip-on”,”value”:”clip-on”},{“name”:”Range”,”normalizedValue”:”Linergy”,”value”:”Linergy”},{“name”:”Range Compatibility”,”normalizedValue”:”Prisma G || Prisma P || Prisma PH || Prisma Pack || Spacial || Kaedra || Pragma || TeSys”,”value”:”Prisma G || Prisma P || Prisma PH || Prisma Pack || Spacial || Kaedra || Pragma || TeSys”},{“name”:”Connection Position”,”normalizedValue”:”top”,”value”:”top”},{“name”:”Product Certifications”,”normalizedValue”:”CSA || EAC || cURus || VDE || GL”,”value”:”CSA || EAC || cURus || VDE || GL”},{“name”:”Flame Retardance”,”normalizedValue”:”V0 0.8 mm UL 94″,”value”:”V0 0.8 mm UL 94″},{“name”:”Number Of Terminals”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Connections – Terminals”,”normalizedValue”:”1 x push-in upstream || 1 x push-in downstream”,”value”:”1 x push-in upstream || 1 x push-in downstream”},{“name”:”Product Name”,”normalizedValue”:”Linergy TR”,”value”:”Linergy TR”},{“name”:”Terminal Block Level”,”normalizedValue”:”1″,”value”:”1″},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”400 V EN/IEC 60947-7-1 || 300 V cURus || 300 V CSA”,”value”:”400 V EN/IEC 60947-7-1 || 300 V cURus || 300 V CSA”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Poland”,”value”:”Poland”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “PUSH-IN TERMINAL, 20 A”