Description
[{“name”:”Material”,”normalizedValue”:”Wemid”,”value”:”Wemid”},{“name”:”Standards”,”normalizedValue”:”In accordance with IEC 60947-7-1″,”value”:”In accordance with IEC 60947-7-1″},{“name”:”Voltage size C (cURus)”,”normalizedValue”:”150 V”,”value”:”150 V”},{“name”:”Connection direction”,”normalizedValue”:”top”,”value”:”top”},{“name”:”Wire connection cross-section, finely stranded, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Wire cross section max. (IECEX)”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Height (inches)”,”normalizedValue”:”3.701 in”,”value”:”3.701 inch”},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”200,039 to 70,089,609″,”value”:”200039-70089609″},{“name”:”Colour of operational elements”,”normalizedValue”:”blue, red”,”value”:”red / blue”},{“name”:”Continuous operating temp., max.”,”normalizedValue”:”130 deg C”,”value”:”130 °C”},{“name”:”Current size B (CSA)”,”normalizedValue”:”51 A”,”value”:”51 A”},{“name”:”Connection cross-section, stranded, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Blade Size”,”normalizedValue”:”1 mm x 5.5 mm”,”value”:”1.0 x 5.5 mm”},{“name”:”Current (ATEX)”,”normalizedValue”:”45 A”,”value”:”45 A”},{“name”:”Max. voltage (ATEX)”,”normalizedValue”:”352 V”,”value”:”352 V”},{“name”:”Current (IECEX)”,”normalizedValue”:”45 A”,”value”:”45 A”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Twin wire-end ferrules, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Depth (inches)”,”normalizedValue”:”2.106 in”,”value”:”2.106 inch”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Number of potentials”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Surge voltage category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Wire connection cross-section, solid core, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Installation advice”,”normalizedValue”:”Rail”,”value”:”Rail”},{“name”:”PE connection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Pollution severity”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Clamping range, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Wire connection cross-section, solid core, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Wire cross section max. (CSA)”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Wire connection cross section, finely stranded, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Current at maximum wires”,”normalizedValue”:”57 A”,”value”:”57 A”},{“name”:”Number of connections”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Conductor size Factory wiring min. (cURus)”,”normalizedValue”:”20 AWG”,”value”:”20 AWG”},{“name”:”Connection cross-section, stranded, min.”,”normalizedValue”:”0.5 sq mm”,”value”:”0.5 mm²”},{“name”:”Rated voltage”,”normalizedValue”:”500 V”,”value”:”500 V”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Storage temperature, max.”,”normalizedValue”:”40 deg C”,”value”:”40 °C”},{“name”:”Number of clamping points per level”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Certificate No. (ATEX)”,”normalizedValue”:”TUEV17ATEX8030U”,”value”:”TUEV17ATEX8030U”},{“name”:”End cover plate required”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Twin wire-end ferrules, max.”,”normalizedValue”:”4 sq mm”,”value”:”4 mm²”},{“name”:”Conductor size Factory wiring max. (cURus)”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Wire cross section min. (CSA)”,”normalizedValue”:”20 AWG”,”value”:”20 AWG”},{“name”:”Gauge to IEC 60947-1″,”normalizedValue”:”A6″,”value”:”A6″},{“name”:”Storage temperature, min.”,”normalizedValue”:”10 deg C”,”value”:”10 °C”},{“name”:”PE function”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Rail”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”Volume resistance according to IEC 60947-7-x”,”normalizedValue”:”0.56 milliohm”,”value”:”0.56 mΩ”},{“name”:”Voltage size B (CSA)”,”normalizedValue”:”150 V”,”value”:”150 V”},{“name”:”Rated impulse withstand voltage”,”normalizedValue”:”6 kV”,”value”:”6 kV”},{“name”:”Number of Levels”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Type of fixing”,”normalizedValue”:”Snap-on”,”value”:”Snap-on”},{“name”:”Conductor size Field wiring max. (cURus)”,”normalizedValue”:”6 AWG”,”value”:”6 AWG”},{“name”:”Certificate No. (cURus)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Continuous operating temp., min.”,”normalizedValue”:”-60 deg C”,”value”:”-60 °C”},{“name”:”Voltage size D (cURus)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Max. voltage (IECEX)”,”normalizedValue”:”352 V”,”value”:”352 V”},{“name”:”Voltage size C (CSA)”,”normalizedValue”:”150 V”,”value”:”150 V”},{“name”:”Power loss in accordance with IEC 60947-7-x”,”normalizedValue”:”1.82 W”,”value”:”1.82 W”},{“name”:”Current size B (cURus)”,”normalizedValue”:”51 A”,”value”:”51 A”},{“name”:”Rated cross-section”,”normalizedValue”:”10 mm²”,”value”:”10 mm²”},{“name”:”Clamping range, min.”,”normalizedValue”:”0.5 sq mm”,”value”:”0.5 mm²”},{“name”:”Conductor size Field wiring min. (cURus)”,”normalizedValue”:”20 AWG”,”value”:”20 AWG”},{“name”:”Width (inches)”,”normalizedValue”:”0.394 in”,”value”:”0.394 inch”},{“name”:”Storage temperature”,”normalizedValue”:”10 deg C”,”value”:”10°C…40°C”},{“name”:”Stripping length”,”normalizedValue”:”18 mm”,”value”:”18 mm”},{“name”:”Depth including DIN rail”,”normalizedValue”:”54 mm”,”value”:”54 mm”},{“name”:”Current size D (cURus)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Current size C (cURus)”,”normalizedValue”:”51 A”,”value”:”51 A”},{“name”:”Current size D (CSA)”,”normalizedValue”:”15 A”,”value”:”15 A”},{“name”:”Type of mounting”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”Certificate No. (IECEX)”,”normalizedValue”:”IECEXTUR17.0015U”,”value”:”IECEXTUR17.0015U”},{“name”:”Voltage size B (cURus)”,”normalizedValue”:”150 V”,”value”:”150 V”},{“name”:”Open sides”,”normalizedValue”:”right”,”value”:”right”},{“name”:”Current size C (CSA)”,”normalizedValue”:”51 A”,”value”:”51 A”},{“name”:”Voltage size D (CSA)”,”normalizedValue”:”150 V”,”value”:”150 V”},{“name”:”Approvals”,”normalizedValue”:”BURVER, CE, CSA, cURus, DNV GL, IECEXTUR, TUEVNATEX”,”value”:”BURVER, CE, CSA, cURus, DNV GL, IECEXTUR, TUEVNATEX”},{“name”:”Type of connection”,”normalizedValue”:”PUSH IN”,”value”:”PUSH IN”},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 20″,”value”:”AWG 20″},{“name”:”Marking EN 60079-7″,”normalizedValue”:”Ex eb II C Gb”,”value”:”Ex eb II C Gb”},{“name”:”Colour”,”normalizedValue”:”dark beige”,”value”:”dark beige”},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 6″,”value”:”AWG 6″},{“name”:”Rated current”,”normalizedValue”:”57 A”,”value”:”57 A”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Wire cross section max. (ATEX)”,”normalizedValue”:”10 sq mm”,”value”:”10 mm²”},{“name”:”Number of potentials per tier”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Germany”,”value”:”Germany”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.