Overload Module, 1.25 to 5A, Class 10, 3P

$193,99

Overload Module, Maximum Rated Motor Current Adjustment 5 A, Minumum Rated Motor Current Adjustment 1.25 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67

9999 in stock

SKU: GRG1597321 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Overload Module”,”rank”:1,”value”:”Overload Module”},{“name”:”Voltage”,”normalizedValue”:”24V AC”,”rank”:2,”value”:”24V AC”},{“name”:”Phase”,”normalizedValue”:”Single”,”rank”:3,”value”:”Single”},{“name”:”Thermal Setting Range (A)”,”normalizedValue”:”1.25 to 5″,”rank”:4,”value”:”1.25 to 5.00″},{“name”:”For Use With”,”normalizedValue”:”LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12″,”rank”:5,”value”:”LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12″},{“name”:”Features”,”normalizedValue”:”Earth Fault Protection”,”value”:”Earth Fault Protection”},{“name”:”Trip Class – Overload”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Reset Type – Relay”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Trip Class”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Current Range”,”normalizedValue”:”1.25 to 5 A”,”value”:”1.25 to 5.00A”},{“name”:”Standards”,”normalizedValue”:”ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed”,”value”:”ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed”},{“name”:”Sensing Method”,”normalizedValue”:”Electronic”,”value”:”Electronic”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”158 Degrees F”,”value”:”158 Degrees F”},{“name”:”Compatible with Series”,”normalizedValue”:”TeSys Ultra”,”value”:”TeSys Ultra”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Wire Leads”,”value”:”Wire Leads”},{“name”:”Reset Type”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Maximum Rated Motor Current Adjustment”,”normalizedValue”:”5 A”,”value”:”5 A”},{“name”:”Minumum Rated Motor Current Adjustment”,”normalizedValue”:”1.25 A”,”value”:”1.25 A”},{“name”:”Coil Voltage”,”normalizedValue”:”24V AC”,”value”:”24V AC”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690V AC”,”value”:”690V AC”},{“name”:”Compatible with Manufacturer Model Number”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-13 Degrees F”,”value”:”-13 Degrees F”},{“name”:”Compatible Manufacturer Part Number”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Compatible Manufacturer Model Number”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”For Use With Mfr. Model Number”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Shock Resistance”,”normalizedValue”:”10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27″,”value”:”10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27″},{“name”:”Typical Current Consumption”,”normalizedValue”:”140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38″,”value”:”140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38″},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Fire Resistance”,”normalizedValue”:”960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12″,”value”:”960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12″},{“name”:”Product Certifications”,”normalizedValue”:”CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine”,”value”:”CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-44 || AC-43 || AC-41″,”value”:”AC-44 || AC-43 || AC-41″},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”24 V AC”,”value”:”24 V AC”},{“name”:”Load Type”,”normalizedValue”:”single-phase motor”,”value”:”single-phase motor”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m)”,”value”:”6561.68 ft (2000 m)”},{“name”:”Safe Separation Of Circuit”,”normalizedValue”:”400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1″,”value”:”400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1″},{“name”:”Depth”,”normalizedValue”:”60 mm”,”value”:”60 mm”},{“name”:”Network Frequency”,”normalizedValue”:”40 to 60 Hz”,”value”:”40 to 60 Hz”},{“name”:”Height”,”normalizedValue”:”66 mm”,”value”:”66 mm”},{“name”:”Vibration Resistance”,”normalizedValue”:”2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6″,”value”:”2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6″},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”690 V AC”,”value”:”690 V AC”},{“name”:”Fixing Mode”,”normalizedValue”:”Plug-in front face)”,”value”:”plug-in front face)”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1″,”value”:”IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1″},{“name”:”Resistance To Radiated Fields”,”normalizedValue”:”10 V/m 3 IEC 61000-4-3″,”value”:”10 V/m 3 IEC 61000-4-3″},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out”,”value”:”20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out”},{“name”:”Device Application”,”normalizedValue”:”motor control || motor protection”,”value”:”motor control || motor protection”},{“name”:”Immunity To Radioelectric Fields”,”normalizedValue”:”10 V IEC 61000-4-6″,”value”:”10 V IEC 61000-4-6″},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”3 ms”,”value”:”3 ms”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947-6-2″,”value”:”6 kV IEC 60947-6-2″},{“name”:”Motor Power Kw”,”normalizedValue”:”0.55 kW 400 to 440 V AC 50/60 Hz 1 phase”,”value”:”0.55 kW 400 to 440 V AC 50/60 Hz 1 phase”},{“name”:”Protective Treatment”,”normalizedValue”:”TH IEC 60068″,”value”:”TH IEC 60068″},{“name”:”Compatibility Code”,”normalizedValue”:”LUCC”,”value”:”LUCC”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1″,”value”:”690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1″},{“name”:”Reset”,”normalizedValue”:”manual reset”,”value”:”manual reset”},{“name”:”Resistance To Fast Transients”,”normalizedValue”:”2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4″,”value”:”2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4″},{“name”:”Product Or Component Type”,”normalizedValue”:”advanced control unit”,”value”:”advanced control unit”},{“name”:”Product Name”,”normalizedValue”:”TeSys Ultra”,”value”:”TeSys Ultra”},{“name”:”Product Specific Application”,”normalizedValue”:”basic protection and advanced functions, communication”,”value”:”basic protection and advanced functions, communication”},{“name”:”Tripping Threshold”,”normalizedValue”:”14.2 x Ir +/- 20 %”,”value”:”14.2 x Ir +/- 20 %”},{“name”:”Resistance To Electrostatic Discharge”,”normalizedValue”:”8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2″,”value”:”8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2″},{“name”:”Thermal Overload Class”,”normalizedValue”:”class 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508″,”value”:”class 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508″},{“name”:”Function Available”,”normalizedValue”:”protection against overload and short-circuit || manual reset || earth fault protection || protection against phase failure and phase imbalance”,”value”:”protection against overload and short-circuit || manual reset || earth fault protection || protection against phase failure and phase imbalance”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-85°C”,”value”:”-40-85°C”},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Product Compatibility”,”normalizedValue”:”power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B”,”value”:”power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B”},{“name”:”Heat Dissipation”,”normalizedValue”:”2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38″,”value”:”2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38″},{“name”:”Non-Dissipating Shock Wave”,”normalizedValue”:”1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2″,”value”:”1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2″},{“name”:”Operating Time”,”normalizedValue”:”35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit”,”value”:”35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Device Short Name”,”normalizedValue”:”LUCC”,”value”:”LUCC”},{“name”:”Immunity To Voltage Dips”,”normalizedValue”:”70 % / 500 ms IEC 61000-4-11″,”value”:”70 % / 500 ms IEC 61000-4-11″},{“name”:”Thermal Protection Adjustment Range”,”normalizedValue”:”1.25-5 A”,”value”:”1.25-5 A”},{“name”:”Compatible with Manufacturer Model No.”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Compatible with Mfr. Model No.”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”For Use with Mfr Model Number”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Compatible Pump Manufacturer Part Number”,”normalizedValue”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Overload Module, 1.25 to 5A, Class 10, 3P”