Description
[{“name”:”Item”,”normalizedValue”:”Overload Module”,”rank”:1,”value”:”Overload Module”},{“name”:”Voltage”,”normalizedValue”:”110-240V AC / 110-220V DC”,”rank”:2,”value”:”110-240V AC/110-220V DC”},{“name”:”Phase”,”normalizedValue”:”Single”,”rank”:3,”value”:”Single”},{“name”:”Thermal Setting Range (A)”,”normalizedValue”:”1.25 to 5″,”rank”:4,”value”:”1.25 to 5.00″},{“name”:”For Use With”,”normalizedValue”:”LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12″,”rank”:5,”value”:”LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12″},{“name”:”Reset Type – Relay”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Standards”,”normalizedValue”:”ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed”,”value”:”ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed”},{“name”:”Trip Class”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Features”,”normalizedValue”:”Earth Fault Protection”,”value”:”Earth Fault Protection”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Current Range”,”normalizedValue”:”1.25 to 5 A”,”value”:”1.25 to 5.00A”},{“name”:”Trip Class – Overload”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Sensing Method”,”normalizedValue”:”Electronic”,”value”:”Electronic”},{“name”:”Maximum Rated Motor Current Adjustment”,”normalizedValue”:”5 A”,”value”:”5 A”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690V AC”,”value”:”690V AC”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”158 Degrees F”,”value”:”158 Degrees F”},{“name”:”Minumum Rated Motor Current Adjustment”,”normalizedValue”:”1.25 A”,”value”:”1.25 A”},{“name”:”Coil Voltage”,”normalizedValue”:”110-240V AC/DC”,”value”:”110-240V AC/DC”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Wire Leads”,”value”:”Wire Leads”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-13 Degrees F”,”value”:”-13 Degrees F”},{“name”:”Compatible with Series”,”normalizedValue”:”TeSys Ultra”,”value”:”TeSys Ultra”},{“name”:”Compatible with Manufacturer Model Number”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Reset Type”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Compatible Manufacturer Part Number”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Compatible Manufacturer Model Number”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”For Use With Mfr. Model Number”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Depth”,”normalizedValue”:”60 mm”,”value”:”60 mm”},{“name”:”Typical Current Consumption”,”normalizedValue”:”280 mA 110 to 240 V AC I maximum while closing with LUB12 || 280 mA 110 to 240 V AC I maximum while closing with LUB32 || 280 mA 110 to 240 V AC I maximum while closing with LUB38 || 280 mA 110 to 220 V DC I maximum while closing with LUB12 || 280 mA 110 to 220 V DC I maximum while closing with LUB32 || 280 mA 110 to 220 V DC I maximum while closing with LUB38 || 35 mA 110 to 240 V AC I rms sealed with LUB12 || 25 mA 110 to 240 V AC I rms sealed with LUB32 || 25 mA 110 to 240 V AC I rms sealed with LUB38 || 35 mA 110 to 220 V DC I rms sealed with LUB12 || 25 mA 110 to 220 V DC I rms sealed with LUB32 || 25 mA 110 to 220 V DC I rms sealed with LUB38″,”value”:”280 mA 110 to 240 V AC I maximum while closing with LUB12 || 280 mA 110 to 240 V AC I maximum while closing with LUB32 || 280 mA 110 to 240 V AC I maximum while closing with LUB38 || 280 mA 110 to 220 V DC I maximum while closing with LUB12 || 280 mA 110 to 220 V DC I maximum while closing with LUB32 || 280 mA 110 to 220 V DC I maximum while closing with LUB38 || 35 mA 110 to 240 V AC I rms sealed with LUB12 || 25 mA 110 to 240 V AC I rms sealed with LUB32 || 25 mA 110 to 240 V AC I rms sealed with LUB38 || 35 mA 110 to 220 V DC I rms sealed with LUB12 || 25 mA 110 to 220 V DC I rms sealed with LUB32 || 25 mA 110 to 220 V DC I rms sealed with LUB38″},{“name”:”Shock Resistance”,”normalizedValue”:”10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27″,”value”:”10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27″},{“name”:”Network Frequency”,”normalizedValue”:”40 to 60 Hz”,”value”:”40 to 60 Hz”},{“name”:”Protective Treatment”,”normalizedValue”:”TH IEC 60068″,”value”:”TH IEC 60068″},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Resistance To Fast Transients”,”normalizedValue”:”2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4″,”value”:”2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4″},{“name”:”Resistance To Radiated Fields”,”normalizedValue”:”10 V/m 3 IEC 61000-4-3″,”value”:”10 V/m 3 IEC 61000-4-3″},{“name”:”Product Specific Application”,”normalizedValue”:”basic protection and advanced functions, communication”,”value”:”basic protection and advanced functions, communication”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”88 to 264 V AC 110 to 240 V in operation || 88 to 242 V DC 110 to 220 V in operation || 55 V AC 110 to 240 V drop-out || 55 V DC 110 to 220 V drop-out”,”value”:”88 to 264 V AC 110 to 240 V in operation || 88 to 242 V DC 110 to 220 V in operation || 55 V AC 110 to 240 V drop-out || 55 V DC 110 to 220 V drop-out”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-85°C”,”value”:”-40-85°C”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m)”,”value”:”6561.68 ft (2000 m)”},{“name”:”Operating Time”,”normalizedValue”:”35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 control circuit”,”value”:”35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 control circuit”},{“name”:”Non-Dissipating Shock Wave”,”normalizedValue”:”1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2″,”value”:”1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2″},{“name”:”Reset”,”normalizedValue”:”manual reset”,”value”:”manual reset”},{“name”:”Product Certifications”,”normalizedValue”:”CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine”,”value”:”CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine”},{“name”:”Product Name”,”normalizedValue”:”TeSys Ultra”,”value”:”TeSys Ultra”},{“name”:”Thermal Protection Adjustment Range”,”normalizedValue”:”1.25-5 A”,”value”:”1.25-5 A”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”110 to 240 V AC || 110 to 220 V DC”,”value”:”110 to 240 V AC || 110 to 220 V DC”},{“name”:”Compatibility Code”,”normalizedValue”:”LUCC”,”value”:”LUCC”},{“name”:”Motor Power Kw”,”normalizedValue”:”0.55 kW 400 to 440 V AC 50/60 Hz 1 phase”,”value”:”0.55 kW 400 to 440 V AC 50/60 Hz 1 phase”},{“name”:”Resistance To Electrostatic Discharge”,”normalizedValue”:”8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2″,”value”:”8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2″},{“name”:”Immunity To Voltage Dips”,”normalizedValue”:”70 % / 500 ms IEC 61000-4-11″,”value”:”70 % / 500 ms IEC 61000-4-11″},{“name”:”Utilisation Category”,”normalizedValue”:”AC-43 || AC-44 || AC-41″,”value”:”AC-43 || AC-44 || AC-41″},{“name”:”Product Compatibility”,”normalizedValue”:”power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU”,”value”:”power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU”},{“name”:”Fire Resistance”,”normalizedValue”:”960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12″,”value”:”960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12″},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”Safe Separation Of Circuit”,”normalizedValue”:”400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1″,”value”:”400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1″},{“name”:”Tripping Threshold”,”normalizedValue”:”14.2 x Ir +/- 20 %”,”value”:”14.2 x Ir +/- 20 %”},{“name”:”Device Short Name”,”normalizedValue”:”LUCC”,”value”:”LUCC”},{“name”:”Thermal Overload Class”,”normalizedValue”:”class 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508″,”value”:”class 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508″},{“name”:”Vibration Resistance”,”normalizedValue”:”2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6″,”value”:”2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6″},{“name”:”Fixing Mode”,”normalizedValue”:”Plug-in front face)”,”value”:”plug-in front face)”},{“name”:”Function Available”,”normalizedValue”:”protection against overload and short-circuit || manual reset || protection against phase failure and phase imbalance || earth fault protection”,”value”:”protection against overload and short-circuit || manual reset || protection against phase failure and phase imbalance || earth fault protection”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1″,”value”:”690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1″},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”690 V AC”,”value”:”690 V AC”},{“name”:”Product Or Component Type”,”normalizedValue”:”advanced control unit”,”value”:”advanced control unit”},{“name”:”Immunity To Radioelectric Fields”,”normalizedValue”:”10 V IEC 61000-4-6″,”value”:”10 V IEC 61000-4-6″},{“name”:”Height”,”normalizedValue”:”66 mm”,”value”:”66 mm”},{“name”:”Load Type”,”normalizedValue”:”single-phase motor”,”value”:”single-phase motor”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”3 ms”,”value”:”3 ms”},{“name”:”Heat Dissipation”,”normalizedValue”:”2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38″,”value”:”2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947-6-2″,”value”:”6 kV IEC 60947-6-2″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1″,”value”:”IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1″},{“name”:”Device Application”,”normalizedValue”:”motor control || motor protection”,”value”:”motor control || motor protection”},{“name”:”Compatible with Manufacturer Model No.”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Compatible with Mfr. Model No.”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”For Use with Mfr Model Number”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Compatible Pump Manufacturer Part Number”,”normalizedValue”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″,”value”:”LU2B12FU, LU2B32FU, LU2B38FU, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.