Description
[{“name”:”Full Load Amps-Inductive”,”normalizedValue”:”32 A”,”rank”:1,”value”:”32 A”},{“name”:”Item”,”normalizedValue”:”IEC Magnetic Contactor”,”rank”:1,”value”:”IEC Magnetic Contactor”},{“name”:”Full Load Amps-Resistive”,”normalizedValue”:”45 A”,”rank”:2,”value”:”45 A”},{“name”:”Action”,”normalizedValue”:”Non-Reversing”,”rank”:2,”value”:”Non-Reversing”},{“name”:”Type”,”normalizedValue”:”Full voltage non-reversing contactor”,”rank”:2,”value”:”Full voltage non-reversing contactor”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:3,”value”:”3″},{“name”:”Coil Volts”,”normalizedValue”:”480 V AC”,”rank”:4,”value”:”480 V AC”},{“name”:”Reversing”,”normalizedValue”:”No”,”rank”:5,”value”:”No”},{“name”:”HP @ 1 Phase – 120V”,”normalizedValue”:”3 hp”,”rank”:6,”value”:”3 hp”},{“name”:”HP @ 1 Phase – 230V”,”normalizedValue”:”5″,”rank”:6,”value”:”5″},{“name”:”Height”,”normalizedValue”:”1.77 in”,”rank”:7,”value”:”1.77 in”},{“name”:”HP @ 1 Phase – 240V”,”normalizedValue”:”5 hp”,”rank”:7,”value”:”5 hp”},{“name”:”HP @ 3 Phase – 208V”,”normalizedValue”:”10 hp”,”rank”:8,”value”:”10 hp”},{“name”:”Width”,”normalizedValue”:”1.77 in”,”rank”:8,”value”:”1.77 in”},{“name”:”HP @ 3 Phase – 240V”,”normalizedValue”:”10 hp”,”rank”:9,”value”:”10 hp”},{“name”:”Depth”,”normalizedValue”:”3.82 in”,”rank”:9,”value”:”3.82 in”},{“name”:”HP @ 3 Phase – 575V”,”normalizedValue”:”25 hp”,”rank”:9,”value”:”25 hp”},{“name”:”HP @ 3 Phase – 480V”,”normalizedValue”:”20 hp”,”rank”:10,”value”:”20 hp”},{“name”:”Enclosure NEMA Rating”,”normalizedValue”:”No Enclosure”,”rank”:10,”value”:”No Enclosure”},{“name”:”Aux. Contact Configuration”,”normalizedValue”:”1NO”,”rank”:13,”value”:”1NO”},{“name”:”Hz”,”normalizedValue”:”50/60″,”rank”:15,”value”:”50/60″},{“name”:”Frame / Series / Class / Code”,”normalizedValue”:”Frame C”,”value”:”Frame C”},{“name”:”Standards”,”normalizedValue”:”CE, CSA, EN 60947, IEC 60947, RoHS, UL Listed”,”value”:”CE, CSA, EN 60947, IEC 60947, RoHS, UL Listed”},{“name”:”Auxiliary Contact Form”,”normalizedValue”:”1NO”,”value”:”1NO”},{“name”:”NEMA Size”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Series”,”normalizedValue”:”XT”,”value”:”XT”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Terminals”,”value”:”Screw Terminals”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Amperage Rating”,”normalizedValue”:”32 A”,”value”:”32A”},{“name”:”Hp Rating – Max”,”normalizedValue”:”3, 5, 5/ 10, 10, 20, 25 hp (1/3PH @115,200,230/200,230,460,575 V)”,”value”:”3, 5, 5/ 10, 10, 20, 25 hp (1/3PH @115,200,230/200,230,460,575 V)”},{“name”:”Frequency Rating”,”normalizedValue”:”50-60 Hz”,”value”:”50-60 Hz”},{“name”:”Product Width”,”normalizedValue”:”1.85 in”,”value”:”1.85 in”},{“name”:”Product Name”,”normalizedValue”:”Eaton XT IEC contactor”,”value”:”Eaton XT IEC contactor”},{“name”:”Frame Size”,”normalizedValue”:”C”,”value”:”C”},{“name”:”Compliances”,”normalizedValue”:”CE Marked”,”value”:”CE Marked”},{“name”:”Product Height”,”normalizedValue”:”3.898 in”,”value”:”3.898 in”},{“name”:”Coil Voltage”,”normalizedValue”:”412/480V AC”,”value”:”412/480V AC”},{“name”:”Product Length/Depth”,”normalizedValue”:”3.425 in”,”value”:”3.425 in”},{“name”:”Contact Configuration”,”normalizedValue”:”1 NO”,”value”:”1 NO”},{“name”:”Certifications”,”normalizedValue”:”UL Listed,CSA Certified,EN 60947,IEC 60947″,”value”:”UL Listed,CSA Certified,EN 60947,IEC 60947″},{“name”:”NEMA Enclosure Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail, Panel”,”value”:”DIN Rail, Panel”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”No Enclosure”,”value”:”No Enclosure”},{“name”:”Mounting Hole Diameter”,”normalizedValue”:”0.16 in”,”value”:”0.16 in”},{“name”:”Response Time”,”normalizedValue”:”Less Than14 msec (AC Operated Opening Delay), Less Than22 msec (AC Operated Closing Delay), Less Than30 msec (DC Operated Opening Delay), Less Than47 msec (DC Operated Opening Delay)”,”value”:”Less Than14 msec (AC Operated Opening Delay), Less Than22 msec (AC Operated Closing Delay), Less Than30 msec (DC Operated Opening Delay), Less Than47 msec (DC Operated Opening Delay)”},{“name”:”Horsepower @ Three Phase – 480V AC”,”normalizedValue”:”20 HP”,”value”:”20 hp”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Horsepower @ Three Phase – 600V AC”,”normalizedValue”:”25 HP”,”value”:”25 hp”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690 V AC”,”value”:”690V AC”},{“name”:”Reversing Capability”,”normalizedValue”:”Non-Reversing”,”value”:”Non-Reversing”},{“name”:”Full Load Current – Resistive”,”normalizedValue”:”45 A”,”value”:”45 A”},{“name”:”Mounting Hole Distance – Height”,”normalizedValue”:”2.95 in”,”value”:”2.95 in”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”10,000,000″,”value”:”10,000,000″},{“name”:”Full Load Current – Inductive”,”normalizedValue”:”32 A”,”value”:”32 A”},{“name”:”Horsepower @ Single Phase – 240V AC”,”normalizedValue”:”5 HP”,”value”:”5 hp”},{“name”:”Includes Auxiliary Contacts”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Embedded Surge Suppressor”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Overall Height”,”normalizedValue”:”3.9 in”,”value”:”3.9 in”},{“name”:”Number of Auxillary Contacts”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Overall Width”,”normalizedValue”:”1.85 in”,”value”:”1.85 in”},{“name”:”Horsepower @ Three Phase – 240V AC”,”normalizedValue”:”10 HP”,”value”:”10 hp”},{“name”:”Horsepower @ Single Phase – 120V AC”,”normalizedValue”:”3 HP”,”value”:”3 hp”},{“name”:”Overall Depth”,”normalizedValue”:”3.43 in”,”value”:”3.43 in”},{“name”:”Mounting Hole Distance – Width”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Horsepower @ Three Phase – 208V AC”,”normalizedValue”:”10 HP”,”value”:”10 hp”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Terminals”,”value”:”Screw Terminals”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Electrical Operating Durability”,”normalizedValue”:”300 (AC-4 400V Ie), 800 (AC-1 400V Ie), 800 (AC-3 400V Ie)”,”value”:”300 (AC-4 400V Ie), 800 (AC-1 400V Ie), 800 (AC-3 400V Ie)”},{“name”:”Contactor Style”,”normalizedValue”:”IEC”,”value”:”IEC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Romania”,”value”:”Romania”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.