Description
[{“name”:”Item”,”normalizedValue”:”IEC Magnetic Contactor”,”rank”:1,”value”:”IEC Magnetic Contactor”},{“name”:”Full Load Amps-Inductive”,”normalizedValue”:”50 A”,”rank”:1,”value”:”50 A”},{“name”:”Full Load Amps-Resistive”,”normalizedValue”:”80 A”,”rank”:2,”value”:”80 A”},{“name”:”Action”,”normalizedValue”:”Non-Reversing”,”rank”:2,”value”:”Non-Reversing”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:3,”value”:”3″},{“name”:”Coil Volts”,”normalizedValue”:”200 V AC”,”rank”:4,”value”:”200 V AC”},{“name”:”Reversing”,”normalizedValue”:”No”,”rank”:5,”value”:”No”},{“name”:”HP @ 1 Phase – 230V”,”normalizedValue”:”7.5″,”rank”:6,”value”:”7-1/2″},{“name”:”HP @ 1 Phase – 120V”,”normalizedValue”:”3 hp”,”rank”:6,”value”:”3 hp”},{“name”:”HP @ 1 Phase – 240V”,”normalizedValue”:”7 1/2 hp”,”rank”:7,”value”:”7 1/2 hp”},{“name”:”Height”,”normalizedValue”:”2.17 in”,”rank”:7,”value”:”2.17 in”},{“name”:”Width”,”normalizedValue”:”2.17 in”,”rank”:8,”value”:”2.17 in”},{“name”:”HP @ 3 Phase – 208V”,”normalizedValue”:”15 hp”,”rank”:8,”value”:”15 hp”},{“name”:”HP @ 3 Phase – 240V”,”normalizedValue”:”15 hp”,”rank”:9,”value”:”15 hp”},{“name”:”HP @ 3 Phase – 575V”,”normalizedValue”:”40 hp”,”rank”:9,”value”:”40 hp”},{“name”:”Depth”,”normalizedValue”:”4.61 in”,”rank”:9,”value”:”4.61 in”},{“name”:”HP @ 3 Phase – 480V”,”normalizedValue”:”40 hp”,”rank”:10,”value”:”40 hp”},{“name”:”Enclosure NEMA Rating”,”normalizedValue”:”No Enclosure”,”rank”:10,”value”:”No Enclosure”},{“name”:”Aux. Contact Configuration”,”normalizedValue”:”1NO, 1NC”,”rank”:13,”value”:”1NO/1NC”},{“name”:”Hz”,”normalizedValue”:”50/60″,”rank”:15,”value”:”50/60″},{“name”:”Auxiliary Contact Form”,”normalizedValue”:”1NO/1NC”,”value”:”1NO/1NC”},{“name”:”Standards”,”normalizedValue”:”BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed”,”value”:”BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed”},{“name”:”Series”,”normalizedValue”:”TeSys Deca”,”value”:”TeSys Deca”},{“name”:”Includes”,”normalizedValue”:”Everlink Power Connections”,”value”:”Everlink Power Connections”},{“name”:”NEMA Size”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Rated Voltage”,”normalizedValue”:”690V AC, 300V DC”,”value”:”690V AC, 300V DC”},{“name”:”Insulation Resistance Range”,”normalizedValue”:”Greater Than 10 MOhms (Signalling Circuit)”,”value”:”Greater Than 10 MOhms (Signalling Circuit)”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”900 A @ 440V”,”value”:”900 A @ 440V”},{“name”:”Overvoltage Category”,”normalizedValue”:”CAT III”,”value”:”CAT III”},{“name”:”Working Height”,”normalizedValue”:”Up to 9,842.52 ft”,”value”:”Up to 9842.52 ft”},{“name”:”Mounts On”,”normalizedValue”:”Plate, Rail”,”value”:”Plate, Rail”},{“name”:”Electrical Durability”,”normalizedValue”:”1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V)”,”value”:”1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V)”},{“name”:”Net Weight”,”normalizedValue”:”0.855 kg”,”value”:”0.855 kg”},{“name”:”Features”,”normalizedValue”:”Without Built-In Suppressor Module”,”value”:”Without Built-In Suppressor Module”},{“name”:”Max. Temperature”,”normalizedValue”:”850°C”,”value”:”850°C”},{“name”:”Rated Short-Time Withstand Current”,”normalizedValue”:”400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”,”value”:”400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”},{“name”:”Max. Operating Watts”,”normalizedValue”:”15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)”,”value”:”15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)”},{“name”:”Switching Voltage”,”normalizedValue”:”17 V (Signalling Circuit)”,”value”:”17 V (Signalling Circuit)”},{“name”:”Application”,”normalizedValue”:”Motor Control, Resistive Load”,”value”:”Motor Control, Resistive Load”},{“name”:”Includes Protective Cover”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)”,”value”:”Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)”},{“name”:”Rated Making Capacity”,”normalizedValue”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)”,”value”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)”},{“name”:”Electrical Connection”,”normalizedValue”:”Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors”,”value”:”Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors”},{“name”:”Tightening Torque”,”normalizedValue”:”1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)”,”value”:”1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)”},{“name”:”Vibration Resistance”,”normalizedValue”:”4 G (Contactor Closed), 2 G (Contactor Open)”,”value”:”4 G (Contactor Closed), 2 G (Contactor Open)”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Watts Loss”,”normalizedValue”:”4 to 5W”,”value”:”4 to 5W”},{“name”:”Operating Speed”,”normalizedValue”:”3600 cycles per hr”,”value”:”3600 cycles per hr”},{“name”:”Rated Insulation Volts”,”normalizedValue”:”600/690V”,”value”:”600/690V”},{“name”:”Fuse Amps”,”normalizedValue”:”10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)”,”value”:”10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)”},{“name”:”Signalling Circuit Frequency”,”normalizedValue”:”25 to 400 Hz”,”value”:”25 to 400 Hz”},{“name”:”Shock Resistance”,”normalizedValue”:”10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)”,”value”:”10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)”},{“name”:”Environmental Attributes”,”normalizedValue”:”Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3″,”value”:”Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3″},{“name”:”Fire Rating”,”normalizedValue”:”UL 94 V1″,”value”:”UL 94 V1″},{“name”:”Impedance”,”normalizedValue”:”1.5 mOhm”,”value”:”1.5 mOhm”},{“name”:”Operating Time”,”normalizedValue”:”4 to 19 ms (Opening), 12 to 26 ms (Closing)”,”value”:”4 to 19 ms (Opening), 12 to 26 ms (Closing)”},{“name”:”Hold VA”,”normalizedValue”:”13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)”,”value”:”13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)”},{“name”:”Impulse Withstand Voltage”,”normalizedValue”:”6 kV”,”value”:”6 kV”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 msec”,”value”:”1.5 ms”},{“name”:”Switching Current”,”normalizedValue”:”5 mA (Signalling Circuit)”,”value”:”5 mA (Signalling Circuit)”},{“name”:”Thermal Amperage”,”normalizedValue”:”10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)”,”value”:”10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)”},{“name”:”Inrush VA”,”normalizedValue”:”140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)”,”value”:”140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)”},{“name”:”Mechanical Durability”,”normalizedValue”:”6 Mcycles”,”value”:”6 Mcycles”},{“name”:”Contactor Style”,”normalizedValue”:”IEC”,”value”:”IEC”},{“name”:”Horsepower @ Single Phase – 240V AC”,”normalizedValue”:”7.5 HP”,”value”:”7 1/2 hp”},{“name”:”Overall Width”,”normalizedValue”:”2.17 in”,”value”:”2.17 in”},{“name”:”Full Load Current – Inductive”,”normalizedValue”:”50 A”,”value”:”50 A”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Horsepower @ Three Phase – 480V AC”,”normalizedValue”:”40 HP”,”value”:”40 hp”},{“name”:”Overall Height”,”normalizedValue”:”4.8 in”,”value”:”4.8 in”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”No Enclosure”,”value”:”No Enclosure”},{“name”:”Resistance Properties”,”normalizedValue”:”Fire Resistant, Insulation Resistant”,”value”:”Fire Resistant, Insulation Resistant”},{“name”:”Embedded Surge Suppressor”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Horsepower @ Three Phase – 208V AC”,”normalizedValue”:”15 HP”,”value”:”15 hp”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”690 V AC”,”value”:”690V AC”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Number of Auxillary Contacts”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail, Plate”,”value”:”DIN Rail, Plate”},{“name”:”Electrical Operating Durability”,”normalizedValue”:”1,100,000, 1,450,000″,”value”:”1,100,000, 1,450,000″},{“name”:”Coil Voltage”,”normalizedValue”:”200V AC”,”value”:”200V AC”},{“name”:”Overall Depth”,”normalizedValue”:”4.72 in”,”value”:”4.72 in”},{“name”:”NEMA Enclosure Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Full Load Current – Resistive”,”normalizedValue”:”80 A”,”value”:”80 A”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Includes Auxiliary Contacts”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Reversing Capability”,”normalizedValue”:”Non-Reversing”,”value”:”Non-Reversing”},{“name”:”Horsepower @ Single Phase – 120V AC”,”normalizedValue”:”3 HP”,”value”:”3 hp”},{“name”:”Horsepower @ Three Phase – 240V AC”,”normalizedValue”:”15 HP”,”value”:”15 hp”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”Horsepower @ Three Phase – 600V AC”,”normalizedValue”:”40 HP”,”value”:”40 hp”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”6,000,000″,”value”:”6,000,000″},{“name”:”Number of Normally Open Main Contacts”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.