Hazardous Loc Mtr, 3 Ph, TEFC, 1/2 HP, T3B

$519,99

Hazardous Location Motor, Three Phase, Motor Design Three-Phase, 1/2 hp HP, Nameplate RPM 1,725 RPM, No. of Speeds 1, Voltage 208-230/460V AC, Full Load Amps 2.3-2.4/1.2 A, 56 Frame, Usable @ 208V Usable at 208V, Usable @ 200V Not Usable at 200V, Hz 60/50 Hz, Max. Ambient Temp. 40 Degrees C, Motor Service Factor 1, Motor Thermal Protection Auto, Ins. Class B, Hazardous Location Class Class I, Class II, Temp. Code T3B, Motor Enclosure Design Totally Enclosed Fan Cooled, Duty Cycle Continuous

9999 in stock

SKU: GRG1621891 Category:

Description

[{“name”:”Motor Design”,”normalizedValue”:”Three-Phase”,”rank”:1,”value”:”Three-Phase”},{“name”:”Phase”,”normalizedValue”:”Three”,”rank”:2,”value”:”Three”},{“name”:”HP”,”normalizedValue”:”1/2 hp”,”rank”:3,”value”:”1/2 hp”},{“name”:”RPM Range”,”normalizedValue”:”1,701-1,800″,”rank”:4,”value”:”1,701-1,800″},{“name”:”Voltage”,”normalizedValue”:”208-230/460V AC”,”rank”:5,”value”:”208-230/460V AC”},{“name”:”Frame”,”normalizedValue”:”56″,”rank”:6,”value”:”56″},{“name”:”Hazardous Location Class”,”normalizedValue”:”Class I, Class II”,”rank”:7,”value”:”Class I, Class II”},{“name”:”Motor Thermal Protection”,”normalizedValue”:”Auto”,”rank”:8,”value”:”Auto”},{“name”:”Motor Enclosure Design”,”normalizedValue”:”Totally Enclosed Fan Cooled”,”rank”:9,”value”:”Totally Enclosed Fan Cooled”},{“name”:”Motor Mounting Type”,”normalizedValue”:”Rigid Base”,”rank”:10,”value”:”Rigid Base”},{“name”:”Frame Material”,”normalizedValue”:”Rolled steel”,”value”:”Rolled steel”},{“name”:”Hz”,”normalizedValue”:”60/50 Hz”,”value”:”60/50 Hz”},{“name”:”Length Less Shaft”,”normalizedValue”:”12-1/16 in”,”value”:”12 1/16 in”},{“name”:”Ins. Class”,”normalizedValue”:”B”,”value”:”B”},{“name”:”Shaft Length”,”normalizedValue”:”1-7/8 in”,”value”:”1 7/8 in”},{“name”:”Motor Shaft Rotation”,”normalizedValue”:”CCW, CW”,”value”:”CW/CCW”},{“name”:”Full Load Amps”,”normalizedValue”:”2.3-2.4/1.2 A”,”value”:”2.3-2.4/1.2 A”},{“name”:”Motor Bearings”,”normalizedValue”:”Ball”,”value”:”Ball”},{“name”:”Nameplate RPM”,”normalizedValue”:”1,725 RPM”,”value”:”1,725 RPM”},{“name”:”Temp. Code”,”normalizedValue”:”T3B”,”value”:”T3B”},{“name”:”Motor Shaft Design”,”normalizedValue”:”Keyed”,”value”:”Keyed”},{“name”:”Voltage Compatibility”,”normalizedValue”:”208-220/440V AC, 208-230/460V AC, 208-230V AC, 208-240V AC, 208V AC, 220-230/460V AC, 220/460V AC, 230/460V AC, 230V AC, 240V AC, 460V AC”,”value”:”208-220/440V AC, 208-230/460V AC, 208-230V AC, 208-240V AC, 208V AC, 220-230/460V AC, 220/460V AC, 230/460V AC, 230V AC, 240V AC, 460V AC”},{“name”:”Standards”,”normalizedValue”:”CSA Certified (LR47504), UL Listed (E12044)”,”value”:”CSA Certified (LR47504), UL Listed (E12044)”},{“name”:”Includes”,”normalizedValue”:”Conduit Box, Leads through 1 in NPT Nipple”,”value”:”Conduit Box, Leads through 1 in NPT Nipple”},{“name”:”Nominal Efficiency”,”normalizedValue”:”86.5%”,”value”:”86.5 %”},{“name”:”Motor Service Factor”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Item”,”normalizedValue”:”Hazardous Location Motor”,”value”:”Hazardous Location Motor”},{“name”:”Motor Application”,”normalizedValue”:”Hazardous Location”,”value”:”Hazardous Location”},{“name”:”Max. Ambient Temp.”,”normalizedValue”:”40 deg C”,”value”:”40 Degrees C”},{“name”:”Duty”,”normalizedValue”:”Continuous”,”value”:”Continuous”},{“name”:”Shaft Dia.”,”normalizedValue”:”5/8 in”,”value”:”5/8 in”},{“name”:”NEMA Design”,”normalizedValue”:”B”,”value”:”B”},{“name”:”Lead Length”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”Motor Frame Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Overall Length”,”normalizedValue”:”13-15/16 in”,”value”:”13 15/16 in”},{“name”:”Conduit Box Location”,”normalizedValue”:”Exterior”,”value”:”Exterior”},{“name”:”Usable @ 208V”,”normalizedValue”:”Usable at 208V”,”value”:”Usable at 208V”},{“name”:”Duty Cycle”,”normalizedValue”:”Continuous”,”value”:”Continuous”},{“name”:”Motor Mounting Position”,”normalizedValue”:”Horizontal”,”value”:”Horizontal”},{“name”:”Usable @ 200V”,”normalizedValue”:”Not Usable at 200V”,”value”:”Not Usable at 200V”},{“name”:”Voltage @ 50Hz”,”normalizedValue”:”208-230/460V AC”,”value”:”208-230/460V AC”},{“name”:”HP @ 50Hz”,”normalizedValue”:”1/2 hp”,”value”:”1/2 hp”},{“name”:”Full Load Amps @ 50Hz”,”normalizedValue”:”2.3-2.4/1.2 A”,”value”:”2.3-2.4/1.2 A”},{“name”:”RPM @ 50Hz”,”normalizedValue”:”1,725 RPM”,”value”:”1,725 RPM”},{“name”:”Weight”,”normalizedValue”:”28 lb”,”value”:”28 lb”},{“name”:”Service Factor @ 50Hz”,”normalizedValue”:”1″,”value”:”1″},{“name”:”No. of Speeds”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Hazardous Location Group”,”normalizedValue”:”Group C, Group D, Group E, Group F, Group G”,”value”:”Group C, Group D, Group E, Group F, Group G”},{“name”:”Motor Sub Application”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Hazardous Location Division”,”normalizedValue”:”Division I”,”value”:”Division I”},{“name”:”Duty Ratio”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Run Time”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Hazardous Loc Mtr, 3 Ph, TEFC, 1/2 HP, T3B”