Hazardous Loc Mtr, 3 Ph, TEFC, 5 HP, T3B

$1704,99

Hazardous Location Motor, Three Phase, Motor Design Three-Phase, 5 hp HP, Nameplate RPM 3,505 RPM, No. of Speeds 1, Voltage 230V AC, 460V AC, Full Load Amps 11.8/5.9 A, 184T Frame, Usable @ 208V Not Usable at 208V, Usable @ 200V Not Usable at 200V, Hz 60 Hz, Max. Ambient Temp. 40 Degrees C, Motor Service Factor 1.15, Motor Thermal Protection T-Stat, Ins. Class F, Hazardous Location Class Class I, Class II, Temp. Code T3B, Motor Enclosure Design Totally Enclosed Fan Cooled, Duty Cycle Continuous

Out of stock

SKU: GRG3533232 Category:

Description

[{“name”:”Motor Design”,”normalizedValue”:”Three-Phase”,”rank”:1,”value”:”Three-Phase”},{“name”:”Phase”,”normalizedValue”:”Three”,”rank”:2,”value”:”Three”},{“name”:”HP”,”normalizedValue”:”5 hp”,”rank”:3,”value”:”5 hp”},{“name”:”RPM Range”,”normalizedValue”:”3,001-3,600″,”rank”:4,”value”:”3,001-3,600″},{“name”:”Voltage”,”normalizedValue”:”460V AC, 230V AC”,”rank”:5,”value”:”230V AC, 460V AC”},{“name”:”Frame”,”normalizedValue”:”184T”,”rank”:6,”value”:”184T”},{“name”:”Hazardous Location Class”,”normalizedValue”:”Class I, Class II”,”rank”:7,”value”:”Class I, Class II”},{“name”:”Motor Thermal Protection”,”normalizedValue”:”T-Stat”,”rank”:8,”value”:”T-Stat”},{“name”:”Motor Enclosure Design”,”normalizedValue”:”Totally Enclosed Fan Cooled”,”rank”:9,”value”:”Totally Enclosed Fan Cooled”},{“name”:”Motor Mounting Type”,”normalizedValue”:”Rigid Base”,”rank”:10,”value”:”Rigid Base”},{“name”:”Temp. Code”,”normalizedValue”:”T3B”,”value”:”T3B”},{“name”:”Motor Shaft Rotation”,”normalizedValue”:”CCW, CW”,”value”:”CW/CCW”},{“name”:”Motor Application”,”normalizedValue”:”Hazardous Location”,”value”:”Hazardous Location”},{“name”:”Duty”,”normalizedValue”:”Continuous”,”value”:”Continuous”},{“name”:”CC Number”,”normalizedValue”:”CC003A”,”value”:”CC003A”},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60 Hz”},{“name”:”Motor Shaft Design”,”normalizedValue”:”Keyed”,”value”:”Keyed”},{“name”:”Motor Bearings”,”normalizedValue”:”Ball”,”value”:”Ball”},{“name”:”Motor Service Factor”,”normalizedValue”:”1.15″,”value”:”1.15″},{“name”:”Motor Frame Material”,”normalizedValue”:”Cast Iron”,”value”:”Cast Iron”},{“name”:”Ins. Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Full Load Amps”,”normalizedValue”:”11.8/5.9 A”,”value”:”11.8/5.9 A”},{“name”:”Motor Efficiency Group”,”normalizedValue”:”NEMA Premium Efficient”,”value”:”NEMA Premium Efficient”},{“name”:”Item”,”normalizedValue”:”Hazardous Location Motor”,”value”:”Hazardous Location Motor”},{“name”:”Lead Length”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”Overall Length”,”normalizedValue”:”17-7/8 in”,”value”:”17 7/8 in”},{“name”:”Max. Ambient Temp.”,”normalizedValue”:”40 deg C”,”value”:”40 Degrees C”},{“name”:”Length Less Shaft”,”normalizedValue”:”15 in”,”value”:”15 in”},{“name”:”Standards”,”normalizedValue”:”CSA Certified, UL Listed”,”value”:”CSA Certified, UL Listed”},{“name”:”Shaft Length”,”normalizedValue”:”2-7/8 in”,”value”:”2 7/8 in”},{“name”:”Shaft Dia.”,”normalizedValue”:”1-1/8 in”,”value”:”1 1/8 in”},{“name”:”Nominal Efficiency”,”normalizedValue”:”88.5%”,”value”:”88.5 %”},{“name”:”NEMA Design”,”normalizedValue”:”B”,”value”:”B”},{“name”:”Frame Material”,”normalizedValue”:”Cast Iron”,”value”:”Cast Iron”},{“name”:”Nameplate RPM”,”normalizedValue”:”3,505 RPM”,”value”:”3,505 RPM”},{“name”:”Includes”,”normalizedValue”:”(11) Leads in the Conduit Box”,”value”:”(11) Leads in the Conduit Box”},{“name”:”Voltage Compatibility”,”normalizedValue”:”200-230/440V AC, 200-230/460V AC, 208-220/440V AC, 208-230/460V AC, 230/460V AC”,”value”:”200-230/440V AC, 200-230/460V AC, 208-220/440V AC, 208-230/460V AC, 230/460V AC”},{“name”:”Green Certification or Other Recognition”,”normalizedValue”:”NEMA Premium Rated”,”value”:”NEMA Premium(R) Rated”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Motor Mounting Position”,”normalizedValue”:”Horizontal”,”value”:”Horizontal”},{“name”:”Weight”,”normalizedValue”:”200 lb”,”value”:”200 lb”},{“name”:”Usable @ 208V”,”normalizedValue”:”Not Usable at 208V”,”value”:”Not Usable at 208V”},{“name”:”Hazardous Location Division”,”normalizedValue”:”Division I”,”value”:”Division I”},{“name”:”Duty Cycle”,”normalizedValue”:”Continuous”,”value”:”Continuous”},{“name”:”No. of Speeds”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Conduit Box Location”,”normalizedValue”:”Exterior”,”value”:”Exterior”},{“name”:”Usable @ 200V”,”normalizedValue”:”Not Usable at 200V”,”value”:”Not Usable at 200V”},{“name”:”Hazardous Location Group”,”normalizedValue”:”Group D, Group F, Group G”,”value”:”Group D, Group F, Group G”},{“name”:”Full Load Amps @ 50Hz”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”RPM @ 50Hz”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Service Factor @ 50Hz”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”HP @ 50Hz”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Voltage @ 50Hz”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Run Time”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Duty Ratio”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Hazardous Loc Mtr, 3 Ph, TEFC, 5 HP, T3B”