Description
[{“name”:”Item”,”normalizedValue”:”Electromechanical Timer”,”rank”:1,”value”:”Electromechanical Timer”},{“name”:”Voltage”,”normalizedValue”:”208 to 277V AC”,”rank”:2,”value”:”208 to 277V AC”},{“name”:”Amps”,”normalizedValue”:”40″,”rank”:3,”value”:”40 A”},{“name”:”Enclosure Type”,”normalizedValue”:”STEEL”,”rank”:4,”value”:”STEEL”},{“name”:”Min. Time Setting”,”normalizedValue”:”1 hr”,”rank”:5,”value”:”1 hr”},{“name”:”Max. Time Setting”,”normalizedValue”:”23 hr”,”rank”:6,”value”:”23 hr”},{“name”:”Contact Form”,”normalizedValue”:”DPST-NO”,”rank”:7,”value”:”DPST-NO”},{“name”:”Max. On/Off Cycles”,”normalizedValue”:”12″,”rank”:8,”value”:”12″},{“name”:”Finish”,”normalizedValue”:”Metal Enclosure has Gray Enamel”,”value”:”Metal Enclosure has Gray Enamel”},{“name”:”Number of Trippers Included”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Description/Special Features”,”normalizedValue”:”Furnished with a Maximum of 12 Trippers, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day”,”value”:”Furnished with a Maximum of 12 Trippers, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day”},{“name”:”Height”,”normalizedValue”:”7-13/16 in”,”value”:”7 13/16 in”},{“name”:”NEMA Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Type”,”normalizedValue”:”24-Hour”,”value”:”24-Hour”},{“name”:”Mount”,”normalizedValue”:”Wall”,”value”:”Wall”},{“name”:”Depth”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Contact HP @ 120V”,”normalizedValue”:”2 hp”,”value”:”2 hp”},{“name”:”Time Setting Range”,”normalizedValue”:”1 to 23 hr”,”value”:”1 hr. to 23 hr.”},{“name”:”Nominal Max. Time Setting”,”normalizedValue”:”24 hr”,”value”:”24 hr”},{“name”:”Extra Trippers”,”normalizedValue”:”11Z965″,”value”:”11Z965″},{“name”:”Contact HP @ 240V”,”normalizedValue”:”5 hp”,”value”:”5 hp”},{“name”:”Width”,”normalizedValue”:”5 in”,”value”:”5 in”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Day Skipper”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operation Mode”,”normalizedValue”:”24 hr”,”value”:”24 hour”},{“name”:”Maximum On Off Operations”,”normalizedValue”:”10″,”value”:”10″},{“name”:”CSA Certification”,”normalizedValue”:”cCSAus”,”value”:”cCSAus”},{“name”:”Wire Size Min”,”normalizedValue”:”#14 AWG”,”value”:”#14 AWG”},{“name”:”Operating Temperature Min”,”normalizedValue”:”-40°C”,”value”:”-40°C”},{“name”:”Number Of Circuits”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Pilot Duty Load Ratings Ranges”,”normalizedValue”:”1000 VA, 120-277 VAC, 60 Hz”,”value”:”1000 VA, 120-277 VAC, 60 Hz”},{“name”:”Product Width”,”normalizedValue”:”5-1/8 in, 130.2 mm”,”value”:”5.125 in; 130.2 mm”},{“name”:”UL Cerfication File Number”,”normalizedValue”:”UL916″,”value”:”UL916″},{“name”:”Minimum On Off Time”,”normalizedValue”:”1 hr”,”value”:”1 hour”},{“name”:”Operating Temperature Max”,”normalizedValue”:”130°C”,”value”:”130°C”},{“name”:”Solutions”,”normalizedValue”:”Machinery u0026 Pumps, Panel Integrators”,”value”:”Machinery u0026 Pumps; Panel Integrators”},{“name”:”Wiring Option”,”normalizedValue”:”Terminals”,”value”:”Terminals”},{“name”:”Tungsten Load Ratings Ranges”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”UL Certification”,”normalizedValue”:”cULus”,”value”:”cULus”},{“name”:”Resistive Load Ratings”,”normalizedValue”:”40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”,”value”:”40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”},{“name”:”Application Compatibilities”,”normalizedValue”:”LED, HID”,”value”:”LED; HID”},{“name”:”Resistive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-480 VAC, 60 Hz”,”value”:”40 A, 120-480 VAC, 60 Hz”},{“name”:”Motor Load Ratings”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Inductive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”Inductive Load Ratings”,”normalizedValue”:”40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”,”value”:”40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”},{“name”:”Electronic Ballast Load Ratings Ranges”,”normalizedValue”:”16 A, 277 VAC, 60 Hz”,”value”:”16 A, 277 VAC, 60 Hz”},{“name”:”Has Manual Override CVL”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Voltage Ranges”,”normalizedValue”:”208-277 VAC, 60 Hz”,”value”:”208-277 VAC, 60 Hz”},{“name”:”Electronic Ballast Load Ratings”,”normalizedValue”:”16 A, 277 VAC, 60 Hz”,”value”:”16 A, 277 VAC, 60 Hz”},{“name”:”Power Consumption Max W”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”Switch Type”,”normalizedValue”:”DPST”,”value”:”DPST”},{“name”:”Applications”,”normalizedValue”:”Timing/Scheduling ON/OFF; Indoor Lighting Control”,”value”:”Timing/Scheduling ON/OFF; Indoor Lighting Control”},{“name”:”Pilot Duty Load Ratings”,”normalizedValue”:”1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz”,”value”:”1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz”},{“name”:”Skipper Wheel Operation Mode”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Market”,”normalizedValue”:”Commercial, Industrial”,”value”:”Commercial; Industrial”},{“name”:”Packaging Applications”,”normalizedValue”:”Indoor/Outdoor Lighting; Pool Heaters; Pumps; Blowers; Conveyors; Electric Fences; Fans; Filters; Signs; Various Other Electrical Loads; Commercial; Industrial; Residential”,”value”:”Indoor/Outdoor Lighting; Pool Heaters; Pumps; Blowers; Conveyors; Electric Fences; Fans; Filters; Signs; Various Other Electrical Loads; Commercial; Industrial; Residential”},{“name”:”Tungsten Load Ratings”,”normalizedValue”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”},{“name”:”Product Depth”,”normalizedValue”:”3-7/16 in, 87.3 mm”,”value”:”3.4375 in; 87.3 mm”},{“name”:”Product Height”,”normalizedValue”:”7-7/8 in, 200 mm”,”value”:”7.875 in; 200 mm”},{“name”:”Wire Size Max”,”normalizedValue”:”#8 AWG”,”value”:”#8 AWG”},{“name”:”Inductive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”},{“name”:”Product Depth (in)”,”normalizedValue”:”3.4375″,”value”:”3.4375″},{“name”:”Operating Temperature Min (°F)”,”normalizedValue”:”-40″,”value”:”-40″},{“name”:”Motor Load Ratings Ranges”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Operating Temperature Max (°F)”,”normalizedValue”:”130″,”value”:”130″},{“name”:”Features”,”normalizedValue”:”Controls loads up to 40 A per pole; Direct 24-hour control of most loads; Up to 10 ON/OFF operations each day; Minimum ON/OFF times of one hour; Manual override; One ON and one OFF tripper and three day-skipper screws included”,”value”:”Controls loads up to 40 A per pole; Direct 24-hour control of most loads; Up to 10 ON/OFF operations each day; Minimum ON/OFF times of one hour; Manual override; One ON and one OFF tripper and three day-skipper screws included”},{“name”:”Tungsten (NO)”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”},{“name”:”Has Manual Override”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Electronic Ballast”,”normalizedValue”:”16 A, 277 VAC, 60 Hz”,”value”:”16 A, 277 VAC, 60 Hz”},{“name”:”Input Voltage Range(s)”,”normalizedValue”:”208-277 VAC, 60 Hz”,”value”:”208-277 VAC, 60 Hz”},{“name”:”Tungsten Range(s)”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”Minimum ON/OFF Times”,”normalizedValue”:”1 hr”,”value”:”1 hour”},{“name”:”Resistive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz”},{“name”:”Product Width (in)”,”normalizedValue”:”5.125″,”value”:”5.125″},{“name”:”Skipper Wheel”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Product Height (in)”,”normalizedValue”:”7.875″,”value”:”7.875″},{“name”:”Maximum ON/OFF Operations”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Pilot Duty (NO)”,”normalizedValue”:”1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz”,”value”:”1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz”},{“name”:”Maximum Power Consumption (W)”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.