Description
[{“name”:”Item”,”normalizedValue”:”Electromechanical Timer”,”rank”:1,”value”:”Electromechanical Timer”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:2,”value”:”120V AC”},{“name”:”Amps”,”normalizedValue”:”40 A”,”rank”:3,”value”:”40 A”},{“name”:”Enclosure Type”,”normalizedValue”:”Steel”,”rank”:4,”value”:”Steel”},{“name”:”Min. Time Setting”,”normalizedValue”:”3 hr 30 min”,”rank”:5,”value”:”3.5 hr”},{“name”:”Max. Time Setting”,”normalizedValue”:”21 hr”,”rank”:6,”value”:”21 hr”},{“name”:”Contact Form”,”normalizedValue”:”SPST”,”rank”:7,”value”:”SPST”},{“name”:”Max. On/Off Cycles”,”normalizedValue”:”3″,”rank”:8,”value”:”3″},{“name”:”Contact HP @ 240V”,”normalizedValue”:”5 hp”,”value”:”5 hp”},{“name”:”Number of Poles”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Day Skipper”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Height”,”normalizedValue”:”12-1/2 in”,”value”:”12 1/2 in”},{“name”:”Nominal Max. Time Setting”,”normalizedValue”:”7 days”,”value”:”7 day”},{“name”:”Depth”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Description/Special Features”,”normalizedValue”:”Heavy-duty Clutchless Gears Prevent Slipping, Spring Wound Carry-Over”,”value”:”Heavy-duty Clutchless Gears Prevent Slipping, Spring Wound Carry-Over”},{“name”:”Type”,”normalizedValue”:”7-Day”,”value”:”7-Day”},{“name”:”Width”,”normalizedValue”:”8-1/4 in”,”value”:”8 1/4 in”},{“name”:”Contact HP @ 120V”,”normalizedValue”:”2 hp”,”value”:”2 hp”},{“name”:”NEMA Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Time Setting Range”,”normalizedValue”:”3 hr 30 min to 21 hr”,”value”:”3-1/2 hr. to 21 hr.”},{“name”:”Extra Trippers”,”normalizedValue”:”11Z966″,”value”:”11Z966″},{“name”:”Number of Trippers Included”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Mount”,”normalizedValue”:”Wall”,”value”:”wall”},{“name”:”Standards”,”normalizedValue”:”cCSAus, cULus”,”value”:”cCSAus, cULus”},{“name”:”Product Type”,”normalizedValue”:”Timer”,”value”:”Timer”},{“name”:”Operation Mode”,”normalizedValue”:”7 days”,”value”:”7 day”},{“name”:”Operating Temperature Min”,”normalizedValue”:”-40°C”,”value”:”-40°C”},{“name”:”Motor Three Phase Load Ratings”,”normalizedValue”:”7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Number Of Circuits”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Has Manual Override CVL”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Electronic Ballast Load Ratings”,”normalizedValue”:”16 A, 277 VAC, 60 Hz”,”value”:”16 A, 277 VAC, 60 Hz”},{“name”:”Power Consumption Max W”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”CSA Certification”,”normalizedValue”:”cCSAus”,”value”:”cCSAus”},{“name”:”Motor Single Phase Ranges”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Product Depth”,”normalizedValue”:”3-3/4 in, 95.25 mm”,”value”:”3.75 in; 95.25 mm”},{“name”:”Operating Temperature Max”,”normalizedValue”:”130°C”,”value”:”130°C”},{“name”:”UL Cerfication File Number”,”normalizedValue”:”UL917″,”value”:”UL917″},{“name”:”Backup Type”,”normalizedValue”:”Spring Wound Carry-over”,”value”:”Spring Wound Carry-over”},{“name”:”Motor Three Phase Ranges”,”normalizedValue”:”7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”7 1/2 HP, 28 FLA @ 208 VAC, 60 Hz; 10 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Pilot Duty Load Ratings Ranges”,”normalizedValue”:”1000 VA, 120-277 VAC, Per Pole, 60 Hz”,”value”:”1000 VA, 120-277 VAC, Per Pole, 60 Hz”},{“name”:”Market”,”normalizedValue”:”Commercial, Residential”,”value”:”Commercial; Residential”},{“name”:”Inductive Load Ratings”,”normalizedValue”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”},{“name”:”Resistive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-480 VAC, 60 Hz”,”value”:”40 A, 120-480 VAC, 60 Hz”},{“name”:”Product Width”,”normalizedValue”:”9 in, 228.9 mm”,”value”:”9 in; 228.9 mm”},{“name”:”Input Voltage Ranges”,”normalizedValue”:”120 VAC, 60 Hz”,”value”:”120 VAC, 60 Hz”},{“name”:”Wire Size Max”,”normalizedValue”:”#8 AWG”,”value”:”#8 AWG”},{“name”:”Solutions”,”normalizedValue”:”Machinery \u0026 Pumps, Panel Integrators”,”value”:”Machinery \u0026 Pumps; Panel Integrators”},{“name”:”Maximum On Off Operations”,”normalizedValue”:”28″,”value”:”28″},{“name”:”Wiring Option”,”normalizedValue”:”Terminals”,”value”:”Terminals”},{“name”:”Tungsten Load Ratings”,”normalizedValue”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”},{“name”:”Skipper Wheel Operation Mode”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Wire Size Min”,”normalizedValue”:”#14 AWG”,”value”:”#14 AWG”},{“name”:”Pilot Duty Load Ratings”,”normalizedValue”:”1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz”,”value”:”1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz”},{“name”:”Electronic Ballast Load Ratings Ranges”,”normalizedValue”:”16 A, 277 VAC, 60 Hz”,”value”:”16 A, 277 VAC, 60 Hz”},{“name”:”Motor Single Phase Load Ratings”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Switch Type”,”normalizedValue”:”4-PST/NO”,”value”:”4-PST/NO”},{“name”:”Applications”,”normalizedValue”:”Timing/Scheduling ON/OFF; Indoor Lighting Control”,”value”:”Timing/Scheduling ON/OFF; Indoor Lighting Control”},{“name”:”Packaging Applications”,”normalizedValue”:”Heating; Air Conditioning; Pumps; Indoor/Outdoor Lighting; Motors; Signs; Filters; Fans”,”value”:”Heating; Air Conditioning; Pumps; Indoor/Outdoor Lighting; Motors; Signs; Filters; Fans”},{“name”:”Backup Protection Time”,”normalizedValue”:”16 hr”,”value”:”16 Hours”},{“name”:”Tungsten Load Ratings Ranges”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”Product Height”,”normalizedValue”:”13-1/8 in, 333.3 mm”,”value”:”13.125 in; 333.3 mm”},{“name”:”Backup Restoration Time”,”normalizedValue”:”1 Hour for Every 2 Hours Without Power”,”value”:”1 Hour for Every 2 Hours Without Power”},{“name”:”Inductive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”Application Compatibilities”,”normalizedValue”:”LED, HID”,”value”:”LED; HID”},{“name”:”UL Certification”,”normalizedValue”:”cULus”,”value”:”cULus”},{“name”:”Resistive Load Ratings”,”normalizedValue”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 480 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 480 VAC, 60 Hz”},{“name”:”Minimum On Off Time”,”normalizedValue”:”3 hr 30 min”,”value”:”3.5 hours”},{“name”:”Tungsten Range(s)”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”Maximum Power Consumption (W)”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”Product Width (in)”,”normalizedValue”:”9″,”value”:”9″},{“name”:”Minimum ON/OFF Times”,”normalizedValue”:”3 hr 30 min”,”value”:”3.5 hours”},{“name”:”Tungsten (NO)”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”},{“name”:”Skipper Wheel”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Has Manual Override”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Electronic Ballast”,”normalizedValue”:”16 A, 277 VAC, 60 Hz”,”value”:”16 A, 277 VAC, 60 Hz”},{“name”:”Resistive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz”},{“name”:”Pilot Duty (NO)”,”normalizedValue”:”1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz”,”value”:”1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz”},{“name”:”Maximum ON/OFF Operations”,”normalizedValue”:”28″,”value”:”28″},{“name”:”Features”,”normalizedValue”:”Carry-Over Automatically Rewinds When Power Resumes, Separate Clock Motor Terminals”,”value”:”Carry-Over Automatically Rewinds When Power Resumes, Separate Clock Motor Terminals”},{“name”:”Product Depth (in)”,”normalizedValue”:”3.75″,”value”:”3.75″},{“name”:”Inductive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”},{“name”:”Operating Temperature Max (°F)”,”normalizedValue”:”130″,”value”:”130″},{“name”:”Input Voltage Range(s)”,”normalizedValue”:”120 VAC, 60 Hz”,”value”:”120 VAC, 60 Hz”},{“name”:”Operating Temperature Min (°F)”,”normalizedValue”:”-40″,”value”:”-40″},{“name”:”Product Height (in)”,”normalizedValue”:”13.125″,”value”:”13.125″},{“name”:”Operating Temperature Max (°F)”,”normalizedValue”:”130″,”value”:”130″},{“name”:”Operating Temperature Min (°F)”,”normalizedValue”:”-40″,”value”:”-40″},{“name”:”On/Off Cycles – Maximum”,”normalizedValue”:”28″,”value”:”28″},{“name”:”AC Voltage Rating”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Mounting Style”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Horsepower @ 240V – Maximum”,”normalizedValue”:”5 HP”,”value”:”5 hp”},{“name”:”Horsepower @ 120V – Maximum”,”normalizedValue”:”2 HP”,”value”:”2 hp”},{“name”:”Indoor/Outdoor Usage”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Overall Width”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”Number of Trippers – Maximum”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”130 deg F”,”value”:”130 Degrees F”},{“name”:”Overall Height”,”normalizedValue”:”13-1/8 in”,”value”:”13 1/8 in”},{“name”:”Series”,”normalizedValue”:”T7000B”,”value”:”T7000B”},{“name”:”Body Material”,”normalizedValue”:”Metal”,”value”:”Metal”},{“name”:”Time Setting – Maximum”,”normalizedValue”:”7 days”,”value”:”7 day”},{“name”:”Overall Depth”,”normalizedValue”:”3-3/4 in”,”value”:”3 3/4 in”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Time Setting – Minimum”,”normalizedValue”:”3 hr 30 min”,”value”:”3.5 hr”},{“name”:”Compatible Lighting”,”normalizedValue”:”HID, LED”,”value”:”HID, LED”},{“name”:”Application”,”normalizedValue”:”Lighting”,”value”:”Lighting”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Current Rating – Maximum”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.