Electromechanical Timer, 24 Hour, Dpst

$113,99

Electromechanical Timer, 24-Hour, Number of Poles 2, Contact Form DPST, Voltage 208 to 277V AC, Amps 40 A, Contact HP @ 120V 2 hp, Contact HP @ 240V 5 hp, Day Skipper No, Enclosure Type Plastic, Finish Gray Plastic, NEMA Rating 3R, Min. Time Setting 1 hr, Max. Time Setting 23 hr, Max. On/Off Cycles 12, Width 5 1/2 in, Depth 3 13/16 in, Height 9 7/16 in, Number of Trippers Included 2, Extra Trippers 2E054

9999 in stock

SKU: GRG2997181 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Electromechanical Timer”,”rank”:1,”value”:”Electromechanical Timer”},{“name”:”Voltage”,”normalizedValue”:”208 to 277V AC”,”rank”:2,”value”:”208 to 277V AC”},{“name”:”Amps”,”normalizedValue”:”40 A”,”rank”:3,”value”:”40 A”},{“name”:”Enclosure Type”,”normalizedValue”:”Plastic”,”rank”:4,”value”:”Plastic”},{“name”:”Min. Time Setting”,”normalizedValue”:”1 hr”,”rank”:5,”value”:”1 hr”},{“name”:”Max. Time Setting”,”normalizedValue”:”23 hr”,”rank”:6,”value”:”23 hr”},{“name”:”Contact Form”,”normalizedValue”:”DPST”,”rank”:7,”value”:”DPST”},{“name”:”Max. On/Off Cycles”,”normalizedValue”:”12″,”rank”:8,”value”:”12″},{“name”:”Nominal Max. Time Setting”,”normalizedValue”:”24 hr”,”value”:”24 hr”},{“name”:”Depth”,”normalizedValue”:”3-13/16 in”,”value”:”3 13/16 in”},{“name”:”Description/Special Features”,”normalizedValue”:”3R Enclosures in Noncorrosive Plastic, Furnished with a Maximum of 12 Trippers, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day”,”value”:”3R Enclosures in Noncorrosive Plastic, Furnished with a Maximum of 12 Trippers, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day”},{“name”:”Contact HP @ 120V”,”normalizedValue”:”2 hp”,”value”:”2 hp”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Day Skipper”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Type”,”normalizedValue”:”24-Hour”,”value”:”24-Hour”},{“name”:”Height”,”normalizedValue”:”9-7/16 in”,”value”:”9 7/16 in”},{“name”:”Extra Trippers”,”normalizedValue”:”2E054″,”value”:”2E054″},{“name”:”Finish”,”normalizedValue”:”Gray Plastic”,”value”:”Gray Plastic”},{“name”:”Time Setting Range”,”normalizedValue”:”1 to 23 hr”,”value”:”1 hr. to 23 hr.”},{“name”:”NEMA Rating”,”normalizedValue”:”3R”,”value”:”3R”},{“name”:”Mount”,”normalizedValue”:”Hole Wall”,”value”:”Hole Wall”},{“name”:”Contact HP @ 240V”,”normalizedValue”:”5 hp”,”value”:”5 hp”},{“name”:”Width”,”normalizedValue”:”5-1/2 in”,”value”:”5 1/2 in”},{“name”:”Number of Trippers Included”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Standards”,”normalizedValue”:”cCSAus, cULus”,”value”:”cCSAus, cULus”},{“name”:”Product Type”,”normalizedValue”:”Timer”,”value”:”Timer”},{“name”:”Operation Mode”,”normalizedValue”:”24 hr”,”value”:”24 hour”},{“name”:”Product Depth”,”normalizedValue”:”4 in, 101.6 mm”,”value”:”4 in; 101.6 mm”},{“name”:”CSA Certification”,”normalizedValue”:”cCSAus”,”value”:”cCSAus”},{“name”:”Minimum On Off Time”,”normalizedValue”:”1 hr”,”value”:”1 hour”},{“name”:”Product Height”,”normalizedValue”:”10 in, 254 mm”,”value”:”10 in; 254 mm”},{“name”:”Has Manual Override CVL”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Timing Interval”,”normalizedValue”:”1 hr”,”value”:”1 hr”},{“name”:”Electronic Ballast Load Ratings”,”normalizedValue”:”16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC”,”value”:”16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC”},{“name”:”Solutions”,”normalizedValue”:”Machinery & Pumps, Panel Integrators”,”value”:”Machinery & Pumps; Panel Integrators”},{“name”:”Operating Temperature Max”,”normalizedValue”:”130°C”,”value”:”130°C”},{“name”:”Number Of Circuits”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Resistive Load Ratings”,”normalizedValue”:”40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz; 40 A, 347 VAC, 60 Hz”,”value”:”40 A, 480 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz; 40 A, 347 VAC, 60 Hz”},{“name”:”Input Voltage Ranges”,”normalizedValue”:”208-277 VAC, 60 Hz”,”value”:”208-277 VAC, 60 Hz”},{“name”:”Product Width”,”normalizedValue”:”6-1/2 in, 165.1 mm”,”value”:”6 1/2 in; 165.1 mm”},{“name”:”Operating Temperature Min”,”normalizedValue”:”-40°C”,”value”:”-40°C”},{“name”:”Applications”,”normalizedValue”:”Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control”,”value”:”Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control”},{“name”:”Motor Load Ratings”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Knockout Dimensions Bottom”,”normalizedValue”:”(2) combination 1/2\” – 3/4\””,”value”:”(2) combination 1/2\” – 3/4\””},{“name”:”Skipper Wheel Operation Mode”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Market”,”normalizedValue”:”Commercial, Industrial”,”value”:”Commercial; Industrial”},{“name”:”Pilot Duty Load Ratings”,”normalizedValue”:”1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz”,”value”:”1000 VA, 120 VAC, 60 Hz; 1000 VA, 208 VAC, 60 Hz; 1000 VA, 240 VAC, 60 Hz; 1000 VA, 277 VAC, 60 Hz”},{“name”:”Application Compatibilities”,”normalizedValue”:”LED, HID”,”value”:”LED; HID”},{“name”:”Tungsten Load Ratings”,”normalizedValue”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 277 VAC, 60 Hz”},{“name”:”Tungsten Load Ratings Ranges”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”UL Cerfication File Number”,”normalizedValue”:”UL917″,”value”:”UL917″},{“name”:”UL Certification”,”normalizedValue”:”cULus”,”value”:”cULus”},{“name”:”Switch Type”,”normalizedValue”:”DPST”,”value”:”DPST”},{“name”:”Wire Size Min”,”normalizedValue”:”#14 AWG”,”value”:”#14 AWG”},{“name”:”Wire Size Max”,”normalizedValue”:”#8 AWG”,”value”:”#8 AWG”},{“name”:”Knockout Dimensions Back”,”normalizedValue”:”combination 1/2\” – 3/4\””,”value”:”(1) combination 1/2\” – 3/4\””},{“name”:”Wiring Option”,”normalizedValue”:”Terminals”,”value”:”Terminals”},{“name”:”Inductive Load Ratings”,”normalizedValue”:”40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”,”value”:”40 A, 277 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”},{“name”:”Electronic Ballast Load Ratings Ranges”,”normalizedValue”:”16 A, 120-277 VAC”,”value”:”16 A, 120-277 VAC”},{“name”:”Packaging Applications”,”normalizedValue”:”Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps”,”value”:”Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps”},{“name”:”Pilot Duty Load Ratings Ranges”,”normalizedValue”:”1000 VA, 120-277 VAC, 60 Hz”,”value”:”1000 VA, 120-277 VAC, 60 Hz”},{“name”:”Maximum On Off Operations”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Resistive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-480 VAC, 60 Hz”,”value”:”40 A, 120-480 VAC, 60 Hz”},{“name”:”Inductive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”Power Consumption Max W”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”Pilot Duty (NO)”,”normalizedValue”:”1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz”,”value”:”1000 VA, 120 VAC, 60 Hz, 1000 VA, 208 VAC, 60 Hz, 1000 VA, 240 VAC, 60 Hz, 1000 VA, 277 VAC, 60 Hz”},{“name”:”Input Voltage Range(s)”,”normalizedValue”:”208-277 VAC, 60 Hz”,”value”:”208-277 VAC, 60 Hz”},{“name”:”Product Depth (in)”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Tungsten (NO)”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”},{“name”:”Tungsten Range(s)”,”normalizedValue”:”40 A, 120-277 VAC, 60 Hz”,”value”:”40 A, 120-277 VAC, 60 Hz”},{“name”:”Features”,”normalizedValue”:”Manual Override”,”value”:”Manual Override”},{“name”:”Operating Temperature Max (°F)”,”normalizedValue”:”130″,”value”:”130″},{“name”:”Maximum ON/OFF Operations”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Product Width (in)”,”normalizedValue”:”6.5″,”value”:”6.5″},{“name”:”Skipper Wheel”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Minimum ON/OFF Times”,”normalizedValue”:”1 hr”,”value”:”1 hour”},{“name”:”Resistive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 347 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz, 40 A, 347 VAC, 60 Hz, 40 A, 480 VAC, 60 Hz”},{“name”:”Product Height (in)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Has Manual Override”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Power Consumption (W)”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”Electronic Ballast”,”normalizedValue”:”16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC”,”value”:”16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC”},{“name”:”Operating Temperature Min (°F)”,”normalizedValue”:”-40″,”value”:”-40″},{“name”:”Inductive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz, 40 A, 277 VAC, 60 Hz”},{“name”:”Motor Load Ratings Ranges”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Body Material”,”normalizedValue”:”Plastic”,”value”:”Plastic”},{“name”:”Horsepower @ 120V – Maximum”,”normalizedValue”:”2 HP”,”value”:”2 hp”},{“name”:”On/Off Cycles – Maximum”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Indoor/Outdoor Usage”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Application”,”normalizedValue”:”Lighting”,”value”:”Lighting”},{“name”:”Overall Height”,”normalizedValue”:”10 in”,”value”:”10 in”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”3R”,”value”:”3R”},{“name”:”Overall Depth”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Current Rating – Maximum”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Compatible Lighting”,”normalizedValue”:”HID, LED”,”value”:”HID, LED”},{“name”:”Time Setting – Maximum”,”normalizedValue”:”24 hr”,”value”:”24 hr”},{“name”:”Horsepower @ 240V – Maximum”,”normalizedValue”:”5 HP”,”value”:”5 hp”},{“name”:”Time Setting – Minimum”,”normalizedValue”:”1 hr”,”value”:”1 hr”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”130 deg F”,”value”:”130 Degrees F”},{“name”:”Number of Trippers – Maximum”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Mounting Style”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Body Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”AC Voltage Rating”,”normalizedValue”:”208-277V AC”,”value”:”208-277V AC”},{“name”:”Series”,”normalizedValue”:”T100″,”value”:”T100″},{“name”:”Overall Width”,”normalizedValue”:”6-1/2 in”,”value”:”6 1/2 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Electromechanical Timer, 24 Hour, Dpst”