3 Phase Relay 250V 5Amp Rm35

$231,99

3 Phase Relay 250V 5Amp Rm35

9999 in stock

SKU: GRG0854476 Category:

Description

[{“name”:”Coil Volts”,”normalizedValue”:”250VAC/DC”,”rank”:2,”value”:”250VAC/DC”},{“name”:”Item”,”normalizedValue”:”3 Phase Relay 250V 5Amp Rm35″,”value”:”3 Phase Relay 250V 5Amp Rm35″},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60255-1″,”value”:”EN/IEC 60255-1″},{“name”:”Response Time”,”normalizedValue”:”\u003c 200 ms (in the event of a fault)”,”value”:”\u003c 200 ms (in the event of a fault)”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)”,”value”:”IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250 V AC/DC”,”value”:”250 V AC/DC”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60664-1″,”value”:”3 IEC 60664-1″},{“name”:”Shock Resistance”,”normalizedValue”:”5 gn IEC 60068-2-27″,”value”:”5 gn IEC 60068-2-27″},{“name”:”Measurement Range”,”normalizedValue”:”194…528 V voltage AC 50/60 Hz”,”value”:”194…528 V voltage AC 50/60 Hz”},{“name”:”Reset Time”,”normalizedValue”:”1500 ms time delay”,”value”:”1500 ms time delay”},{“name”:”Relative Humidity”,”normalizedValue”:”95-95 % 55-55°C IEC 60068-2-30″,”value”:”95-95 % 55-55°C IEC 60068-2-30″},{“name”:”Maximum Switching Current”,”normalizedValue”:”5 A AC/DC”,”value”:”5 A AC/DC”},{“name”:”Voltage Detection Threshold”,”normalizedValue”:”194 V”,”value”:”194 V”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1″,”value”:”AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1″},{“name”:”Width”,”normalizedValue”:”35 mm”,”value”:”35 mm”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”400 V IEC 60664-1″,”value”:”400 V IEC 60664-1″},{“name”:”Measurement Accuracy”,”normalizedValue”:”+/- 10 % of the full scale value”,”value”:”+/- 10 % of the full scale value”},{“name”:”Control Circuit Frequency”,”normalizedValue”:”50…60 Hz +/- 15 %”,”value”:”50…60 Hz +/- 15 %”},{“name”:”Hysteresis”,”normalizedValue”:”2-2 %”,”value”:”2-2 %”},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”220…480 V AC 50/60 Hz +/- 10 %”,”value”:”220…480 V AC 50/60 Hz +/- 10 %”},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”voltage control relay”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”emission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2″,”value”:”emission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2″},{“name”:”Time Delay Type”,”normalizedValue”:”adjustable 0.3…30 s, 0 + 10 % on crossing the threshold”,”value”:”adjustable 0.3…30 s, 0 + 10 % on crossing the threshold”},{“name”:”Mechanical Durability”,”normalizedValue”:”30000000 cycles”,”value”:”30000000 cycles”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1″,”value”:”0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1″},{“name”:”Product Certifications”,”normalizedValue”:”C-tick || GOST || CSA || GL || UL”,”value”:”C-tick || GOST || CSA || GL || UL”},{“name”:”Tightening Torque”,”normalizedValue”:”0.6-1 N.m IEC 60947-1″,”value”:”0.6-1 N.m IEC 60947-1″},{“name”:”Mounting Support”,”normalizedValue”:”35 mm symmetrical DIN rail conforming to EN/IEC 60715″,”value”:”35 mm symmetrical DIN rail conforming to EN/IEC 60715″},{“name”:”Power Consumption In Va”,”normalizedValue”:”0-22 VA 400 V AC 50 Hz”,”value”:”0-22 VA 400 V AC 50 Hz”},{“name”:”Maximum Measuring Cycle”,”normalizedValue”:”150 msec”,”value”:”150 ms measurement cycle as true rms value”},{“name”:”Housing Material”,”normalizedValue”:”self-extinguishing plastic”,”value”:”self-extinguishing plastic”},{“name”:”Functionality”,”normalizedValue”:”overvoltage and undervoltage detection”,”value”:”overvoltage and undervoltage detection”},{“name”:”Compatibility Code”,”normalizedValue”:”RM3″,”value”:”RM3″},{“name”:”Relay Monitored Parameters”,”normalizedValue”:”overvoltage and undervoltage between phases”,”value”:”overvoltage and undervoltage between phases”},{“name”:”Local Signalling”,”normalizedValue”:”for power ON LED (green) || for relay ON LED (yellow)”,”value”:”for power ON LED (green) || for relay ON LED (yellow)”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals, 1 x 0.5…1 x 4 mm² AWG 20…AWG 11) solid without cable end || screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end || screw terminals, 1 x 0.2…2 x 2.5 mm² AWG 24…AWG 12) flexible with cable end || screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end”,”value”:”screw terminals, 1 x 0.5…1 x 4 mm² AWG 20…AWG 11) solid without cable end || screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end || screw terminals, 1 x 0.2…2 x 2.5 mm² AWG 24…AWG 12) flexible with cable end || screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Nominal Output Current”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 500 MOhm 500 V DC IEC 60255-5 || \u003e 500 MOhm 500 V DC IEC 60664-1″,”value”:”\u003e 500 MOhm 500 V DC IEC 60255-5 || \u003e 500 MOhm 500 V DC IEC 60664-1″},{“name”:”Electrical Durability”,”normalizedValue”:”10000 cycles”,”value”:”10000 cycles”},{“name”:”Product Specific Application”,”normalizedValue”:”for 3-phase supply”,”value”:”for 3-phase supply”},{“name”:”Non-Dissipating Shock Wave”,”normalizedValue”:”4 kV”,”value”:”4 kV”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”194-528 V AC”,”value”:”194-528 V AC”},{“name”:”Switching Capacity In Va”,”normalizedValue”:”1,250 VA”,”value”:”1250 VA”},{“name”:”Operating Position”,”normalizedValue”:”any position without derating”,”value”:”any position without derating”},{“name”:”Relay Type”,”normalizedValue”:”control relay”,”value”:”voltage control relay”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”O, 2 C”,”value”:”2 C/O”},{“name”:”Overvoltage Category”,”normalizedValue”:”III IEC 60664-1″,”value”:”III IEC 60664-1″},{“name”:”Measurement Error”,”normalizedValue”:”\u003c 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation”,”value”:”\u003c 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation”},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA 5 V DC”,”value”:”10 mA 5 V DC”},{“name”:”Dielectric Test Voltage”,”normalizedValue”:”2 kV AC 50 Hz, 1 min”,”value”:”2 kV AC 50 Hz, 1 min”},{“name”:”Operating Rate”,”normalizedValue”:”\u003c= 360 operations/hour full load”,”value”:”\u003c= 360 operations/hour full load”},{“name”:”Run-Up Delay At Power-Up”,”normalizedValue”:”650 msec”,”value”:”650 ms”},{“name”:”Output Contacts”,”normalizedValue”:”1 C/O + 1 C/O, 1 per threshold”,”value”:”1 C/O + 1 C/O, 1 per threshold”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 0.5 % input and measurement circuit || +/- 1 % time delay”,”value”:”+/- 0.5 % input and measurement circuit || +/- 1 % time delay”},{“name”:”Relay Name”,”normalizedValue”:”RM35UB3″,”value”:”RM35UB3″},{“name”:”Quality Labels”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “3 Phase Relay 250V 5Amp Rm35”