Description
[{“name”:”Item – Relay”,”normalizedValue”:”IEC Style Control Relay”,”rank”:1,”value”:”IEC Style Control Relay”},{“name”:”Coil Volts”,”normalizedValue”:”24 V DC”,”rank”:2,”value”:”24V DC”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”10A @ 120/240/480/600V”,”rank”:3,”value”:”10A @ 120/240/480/600V”},{“name”:”DC Contact Rating – Relay”,”normalizedValue”:”2.00A @ 125/250/600V”,”rank”:4,”value”:”2.00A @ 125/250/600V”},{“name”:”Number of Pins – Relay”,”normalizedValue”:”10″,”rank”:5,”value”:”10″},{“name”:”Contact Form – Relay”,”normalizedValue”:”SPST-NO, SPST-NC”,”rank”:6,”value”:”(2) SPST-NC, (2) SPST-NO”},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail, Surface”,”rank”:7,”value”:”DIN Rail, Surface”},{“name”:”Contact Form”,”normalizedValue”:”2NO/2NC”,”value”:”2NO/2NC”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA Certified, EAC, IEC, REACH, RoHS Compliant, UL Listed”,”value”:”CCC, CSA Certified, EAC, IEC, REACH, RoHS Compliant, UL Listed”},{“name”:”Contact Amp Rating (Resistive)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Power Consumption – Relay”,”normalizedValue”:”3 VA”,”value”:”3.0 VA”},{“name”:”Body Depth – Relay”,”normalizedValue”:”2.24 in”,”value”:”2.24 in”},{“name”:”Coil Rating”,”normalizedValue”:”3VA Inrush, 3VA Sealed”,”value”:”3VA Inrush, 3VA Sealed”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.77 in”,”value”:”1.77 in”},{“name”:”Mounting”,”normalizedValue”:”Din Rail/Panel”,”value”:”Din Rail/Panel”},{“name”:”Item”,”normalizedValue”:”IEC Control Relay”,”value”:”IEC Control Relay”},{“name”:”Overall Height – Relay”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Body Height – Relay”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Contact Material”,”normalizedValue”:”Silver Nickel”,”value”:”Silver Nickel”},{“name”:”Hz”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Response Time”,”normalizedValue”:”10 msec (Coil De-Energisation and NO Opening), 15 msec (Coil De-Energisation and NC Closing), 25 to 35 msec (Coil Energisation and NC Opening), 30 to 40 msec (Coil Energisation and NO Closing)”,”value”:”10 msec (Coil De-Energisation and NO Opening), 15 msec (Coil De-Energisation and NC Closing), 25 to 35 msec (Coil Energisation and NC Opening), 30 to 40 msec (Coil Energisation and NO Closing)”},{“name”:”Width”,”normalizedValue”:”45 mm”,”value”:”45 mm”},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC”},{“name”:”Irms Rated Making Capacity”,”normalizedValue”:”110 A IEC 60947″,”value”:”110 A IEC 60947″},{“name”:”Contactor Application”,”normalizedValue”:”control circuit”,”value”:”control circuit”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-50°C”,”value”:”-25-50°C”},{“name”:”Mounting Support”,”normalizedValue”:”rail || plate”,”value”:”rail || plate”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 10 MOhm”,”value”:”\u003e 10 MOhm”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP2X”,”value”:”IP2X”},{“name”:”Pole Contact Composition”,”normalizedValue”:”2 NO + 2 NC”,”value”:”2 NO + 2 NC”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102″,”value”:”V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102″},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG IEC 60947 || 10 A gG VDE 0660″,”value”:”10 A gG IEC 60947 || 10 A gG VDE 0660″},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations contactor open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″,”value”:”vibrations contactor open2 Gn, 5…300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″},{“name”:”Utilisation Category”,”normalizedValue”:”AC-15 || DC-13″,”value”:”AC-15 || DC-13″},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”\u003c= 690 V \u003c= 400 Hz”,”value”:”\u003c= 690 V \u003c= 400 Hz”},{“name”:”Heat Dissipation”,”normalizedValue”:”3 to 3 W”,”value”:”3-3 W”},{“name”:”Device Short Name”,”normalizedValue”:”CA3K”,”value”:”CA3K”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”10000 cyc/h”,”value”:”10000 cyc/h”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”10 A 50°C”,”value”:”10 A 50°C”},{“name”:”Mechanical Durability”,”normalizedValue”:”20 Mcycles”,”value”:”20 Mcycles”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14″,”value”:”690 V IEC 60947 || 750 V VDE 0110 group C || 690 V BS 5424 || 600 V CSA C22.2 No 14″},{“name”:”Inrush Power In W”,”normalizedValue”:”3-3 W 20°C)”,”value”:”3-3 W 20°C)”},{“name”:”Operating Time”,”normalizedValue”:”10 ms coil de-energisation and NO opening || 30…40 ms coil energisation and NO closing || 15 ms coil de-energisation and NC closing || 25…35 ms coil energisation and NC opening”,”value”:”10 ms coil de-energisation and NO opening || 30…40 ms coil energisation and NO closing || 15 ms coil de-energisation and NC closing || 25…35 ms coil energisation and NC opening”},{“name”:”Product Certifications”,”normalizedValue”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”,”value”:”CB Scheme || CCC || UL || CSA || EAC || CE || UKCA”},{“name”:”Depth”,”normalizedValue”:”57 mm”,”value”:”57 mm”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end”,”value”:”screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible with cable end || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-1.5 mm²flexible with cable end || screw clamp terminals 2 0.34-1.5 mm²flexible without cable end”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”operational 0.8…1.15 Uc 50°C) || drop-out 0.1…0.75 Uc 50°C)”,”value”:”operational 0.8…1.15 Uc 50°C) || drop-out 0.1…0.75 Uc 50°C)”},{“name”:”Hold-In Power Consumption In W”,”normalizedValue”:”3-3 W 20°C”,”value”:”3-3 W 20°C”},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Tightening Torque”,”normalizedValue”:”1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm”,”value”:”1.3 N.m screw clamp terminals flat Ø 6 mm || 1.3 N.m screw clamp terminals Philips No 2 6 mm”},{“name”:”Product Name”,”normalizedValue”:”TeSys CAK”,”value”:”TeSys CAK”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-50-80°C”,”value”:”-50-80°C”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m) without derating”,”value”:”6561.68 ft (2000 m) without derating”},{“name”:”Non Overlap Distance”,”normalizedValue”:”0.5 mm”,”value”:”0.5 mm”},{“name”:”Control Circuit Type”,”normalizedValue”:”DC standard”,”value”:”DC standard”},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”control relay”},{“name”:”Height”,”normalizedValue”:”58 mm”,”value”:”58 mm”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”2 msec”,”value”:”2 ms”},{“name”:”Protective Treatment”,”normalizedValue”:”TC IEC 60068″,”value”:”TC IEC 60068″},{“name”:”Body Depth”,”normalizedValue”:”2.24 in”,”value”:”2.24 in”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Number of Pins”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Coil Voltage”,”normalizedValue”:”24 V DC”,”value”:”24V DC”},{“name”:”Power Consumption”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”IP Rating”,”normalizedValue”:”IP2X”,”value”:”IP2X”},{“name”:”Weight”,”normalizedValue”:”0.5 lb”,”value”:”0.5 lb”},{“name”:”Body Width”,”normalizedValue”:”1.77 in”,”value”:”1.77 in”},{“name”:”Contact Rating (DC)”,”normalizedValue”:”2 A @ 125/250/600V”,”value”:”2 A @ 125/250/600V”},{“name”:”Current Rating”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”10 A @ 120/240/480/600V”,”value”:”10 A @ 120/240/480/600V”},{“name”:”Overall Height”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Relay Style”,”normalizedValue”:”IEC”,”value”:”IEC”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp”,”value”:”Screw Clamp”},{“name”:”Compatible with Series”,”normalizedValue”:”Relays”,”value”:”TeSys K Control Relays”},{“name”:”Body Height”,”normalizedValue”:”2.28 in”,”value”:”2.28 in”},{“name”:”Input Voltage”,”normalizedValue”:”24V DC”,”value”:”24V DC”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail and Surface”,”value”:”DIN Rail and Surface”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”France”,”value”:”France”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.