Description
[{“name”:”Width”,”normalizedValue”:”90 mm”,”value”:”90 mm”},{“name”:”Height”,”normalizedValue”:”85 mm”,”value”:”85 mm”},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No 14 , EN 60947-4-1 , EN 60947-5-1 , IEC 60947-4-1 , IEC 60947-5-1 , UL 508 , IEC 60335-1″,”value”:”CSA C22.2 No 14 , EN 60947-4-1 , EN 60947-5-1 , IEC 60947-4-1 , IEC 60947-5-1 , UL 508 , IEC 60335-1″},{“name”:”Depth”,”normalizedValue”:”92 mm”,”value”:”92 mm”},{“name”:”Mechanical Durability”,”normalizedValue”:”15 Mcycles”,”value”:”15 Mcycles”},{“name”:”Operating Time”,”normalizedValue”:”12…22 ms closing , 4…19 ms opening”,”value”:”12…22 ms closing , 4…19 ms opening”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”450 A 440 V power circuit IEC 60947″,”value”:”450 A 440 V power circuit IEC 60947″},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”0.3…0.6 Uc -40-70 °C drop-out AC 50/60 Hz , 0.8…1.1 Uc -40-60 °C operational AC 50 Hz , 0.85…1.1 Uc -40-60 °C operational AC 60 Hz , 1…1.1 Uc 60-70 °C operational AC 50/60 Hz”,”value”:”0.3…0.6 Uc -40-70 °C drop-out AC 50/60 Hz , 0.8…1.1 Uc -40-60 °C operational AC 50 Hz , 0.85…1.1 Uc -40-60 °C operational AC 60 Hz , 1…1.1 Uc 60-70 °C operational AC 50/60 Hz”},{“name”:”Signalling Circuit Frequency”,”normalizedValue”:”25…400 Hz”,”value”:”25…400 Hz”},{“name”:”Rated Short-Time Withstand Current”,”normalizedValue”:”50 A 40 °C – 10 min power circuit, 120 A 40 °C – 1 min power circuit, 240 A 40 °C – 10 s power circuit, 380 A 40 °C – 1 s power circuit, 100 A – 1 s signalling circuit, 120 A – 500 ms signalling circuit, 140 A – 100 ms signalling circuit”,”value”:”50 A 40 °C – 10 min power circuit, 120 A 40 °C – 1 min power circuit, 240 A 40 °C – 10 s power circuit, 380 A 40 °C – 1 s power circuit, 100 A – 1 s signalling circuit, 120 A – 500 ms signalling circuit, 140 A – 100 ms signalling circuit”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact”,”value”:”1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact”},{“name”:”Electrical Durability”,”normalizedValue”:”1.65 Mcycles 25 A AC-3 \u003c= 440 V , 1.4 Mcycles 40 A AC-1 \u003c= 440 V”,”value”:”1.65 Mcycles 25 A AC-3 \u003c= 440 V , 1.4 Mcycles 40 A AC-1 \u003c= 440 V”},{“name”:”Overvoltage Category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Net Weight”,”normalizedValue”:”0.787 kg”,”value”:”0.787 kg”},{“name”:”Tightening Torque”,”normalizedValue”:”control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm , control circuit 1.7 N.m screw clamp terminals Philips No 2 , power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm , power circuit 2.5 N.m screw clamp terminals Philips No 2 , control circuit 1.7 N.m screw clamp terminals pozidriv No 2 , power circuit 2.5 N.m screw clamp terminals pozidriv No 2″,”value”:”control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm , control circuit 1.7 N.m screw clamp terminals Philips No 2 , power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm , power circuit 2.5 N.m screw clamp terminals Philips No 2 , control circuit 1.7 N.m screw clamp terminals pozidriv No 2 , power circuit 2.5 N.m screw clamp terminals pozidriv No 2″},{“name”:”Interlocking Type”,”normalizedValue”:”Mechanical”,”value”:”mechanical”},{“name”:”Product Certifications”,”normalizedValue”:”DNV , CSA , CCC , UL , GL , LROS (Lloyds register of shipping) , BV , RINA , GOST , UKCA”,”value”:”DNV , CSA , CCC , UL , GL , LROS (Lloyds register of shipping) , BV , RINA , GOST , UKCA”},{“name”:”Mounting Support”,”normalizedValue”:”Rail, Plate”,”value”:”rail , plate”},{“name”:”Fire Resistance”,”normalizedValue”:”850°C IEC 60695-2-1″,”value”:”850 °C IEC 60695-2-1″},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V signalling circuit”,”value”:”17 V signalling circuit”},{“name”:”Device Short Name”,”normalizedValue”:”LC2D”,”value”:”LC2D”},{“name”:”Range”,”normalizedValue”:”TeSys, Deca”,”value”:”TeSys , TeSys Deca”},{“name”:”Contactor Application”,”normalizedValue”:”Resistive load”,”value”:”Resistive load, motor control”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”Power circuit 690V IEC 60947-4-1, power circuit 600V CSA, power circuit 600V UL, signalling circuit 690V IEC 60947-1, signalling circuit 600V CSA, signalling circuit 600V UL”,”value”:”Power circuit 690V IEC 60947-4-1, power circuit 600V CSA, power circuit 600V UL, signalling circuit 690V IEC 60947-1, signalling circuit 600V CSA, signalling circuit 600V UL”},{“name”:”Average Impedance”,”normalizedValue”:”2 mOhm – Ith 40 A 50 Hz power circuit”,”value”:”2 mOhm – Ith 40 A 50 Hz power circuit”},{“name”:”Safety Reliability Level”,”normalizedValue”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 , B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″,”value”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 , B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″},{“name”:”Product Or Component Type”,”normalizedValue”:”Reversing contactor”,”value”:”reversing contactor”},{“name”:”Connections – Terminals”,”normalizedValue”:”Control circuit screw clamp terminals 1 1-4 mm²flexible without cable end , control circuit screw clamp terminals 2 1-4 mm²flexible without cable end , control circuit screw clamp terminals 1 1-4 mm²flexible with cable end , control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end , control circuit screw clamp terminals 1 1-4 mm²solid , control circuit screw clamp terminals 2 1-4 mm²solid , power circuit screw clamp terminals 1 2.5-10 mm²flexible without cable end , power circuit screw clamp terminals 2 2.5-10 mm²flexible without cable end , power circuit screw clamp terminals 1 1-10 mm²flexible with cable end , power circuit screw clamp terminals 2 1.5-6 mm²flexible with cable end , power circuit screw clamp terminals 1 1.5-10 mm²solid , power circuit screw clamp terminals 2 2.5-10 mm²solid”,”value”:”Control circuit screw clamp terminals 1 1-4 mm²flexible without cable end , control circuit screw clamp terminals 2 1-4 mm²flexible without cable end , control circuit screw clamp terminals 1 1-4 mm²flexible with cable end , control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end , control circuit screw clamp terminals 1 1-4 mm²solid , control circuit screw clamp terminals 2 1-4 mm²solid , power circuit screw clamp terminals 1 2.5-10 mm²flexible without cable end , power circuit screw clamp terminals 2 2.5-10 mm²flexible without cable end , power circuit screw clamp terminals 1 1-10 mm²flexible with cable end , power circuit screw clamp terminals 2 1.5-6 mm²flexible with cable end , power circuit screw clamp terminals 1 1.5-10 mm²solid , power circuit screw clamp terminals 2 2.5-10 mm²solid”},{“name”:”Product Name”,”normalizedValue”:”TeSys Deca”,”value”:”TeSys Deca”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A 60 °C signalling circuit, 40 A 60 °C power circuit”,”value”:”10 A 60 °C signalling circuit, 40 A 60 °C power circuit”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947″,”value”:”6 kV IEC 60947″},{“name”:”Hold-In Power Consumption In Va”,”normalizedValue”:”7.5-7.5 VA 60 Hz 0.3 20 °C, 7-7 VA 50 Hz 0.3 20 °C”,”value”:”7.5-7.5 VA 60 Hz 0.3 20 °C, 7-7 VA 50 Hz 0.3 20 °C”},{“name”:”Motor Power Kw”,”normalizedValue”:”5.5 kW 220…230 V AC 50-60 Hz , 11 kW 380…400 V AC 50-60 Hz , 11 kW 415 V AC 50-60 Hz , 11 kW 440 V AC 50-60 Hz , 15 kW 500 V AC 50-60 Hz , 15 kW 660…690 V AC 50-60 Hz”,”value”:”5.5 kW 220…230 V AC 50-60 Hz , 11 kW 380…400 V AC 50-60 Hz , 11 kW 415 V AC 50-60 Hz , 11 kW 440 V AC 50-60 Hz , 15 kW 500 V AC 50-60 Hz , 15 kW 660…690 V AC 50-60 Hz”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94″,”value”:”V1 conforming to UL 94″},{“name”:”Protective Treatment”,”normalizedValue”:”THIEC 60068-2-30″,”value”:”TH IEC 60068-2-30″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 front face IEC 60529″,”value”:”IP20 front face IEC 60529″},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Insulation Resistance”,”normalizedValue”:”\u003e 10 MOhm signalling circuit”,”value”:”\u003e 10 MOhm signalling circuit”},{“name”:”Irms Rated Making Capacity”,”normalizedValue”:”140 A AC signalling circuit IEC 60947-5-1 , 250 A DC signalling circuit IEC 60947-5-1 , 450 A 440 V power circuit IEC 60947″,”value”:”140 A AC signalling circuit IEC 60947-5-1 , 250 A DC signalling circuit IEC 60947-5-1 , 450 A 440 V power circuit IEC 60947″},{“name”:”Inrush Power In Va”,”normalizedValue”:”70-70 VA 60 Hz 0.75 20 °C) , 70-70 VA 50 Hz 0.75 20 °C)”,”value”:”70-70 VA 60 Hz 0.75 20 °C) , 70-70 VA 50 Hz 0.75 20 °C)”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Power circuit \u003c= 690 V AC 25…400 Hz, Power circuit \u003c= 300 V DC”,”value”:”Power circuit \u003c= 690 V AC 25…400 Hz, Power circuit \u003c= 300 V DC”},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations contactor open2 Gn, 5…300 Hz , vibrations contactor closed4 Gn, 5…300 Hz , shocks contactor closed15 Gn for 11 ms , shocks contactor open8 Gn for 11 ms”,”value”:”vibrations contactor open2 Gn, 5…300 Hz , vibrations contactor closed4 Gn, 5…300 Hz , shocks contactor closed15 Gn for 11 ms , shocks contactor open8 Gn for 11 ms”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA signalling circuit”,”value”:”5 mA signalling circuit”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-60 to 80°C”,”value”:”-60 to 80°C”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40 to 60°C, 60 to 70 °C with derating”,”value”:”-40 to 60°C, 60 to 70 °C with derating”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-1, AC-3, AC-3e”,”value”:”AC-1, AC-3, AC-3e”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”110V AC, 50/60 Hz”,”value”:”110V AC, 50/60 Hz”},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Auxiliary Contacts Type”,”normalizedValue”:”mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1″,”value”:”Mechanically linked 1 NO + 1 NC IEC 60947-5-1, mirror contact 1 NC IEC 60947-4-1″},{“name”:”Coil Technology”,”normalizedValue”:”Without built-in suppressor module”,”value”:”Without built-in suppressor module”},{“name”:”Power Dissipation Per Pole”,”normalizedValue”:”1.25 W AC-3 , 3.2 W AC-1″,”value”:”1.25 W AC-3 , 3.2 W AC-1″},{“name”:”Device Presentation”,”normalizedValue”:”Preassembled with reversing power busbar”,”value”:”preassembled with reversing power busbar”},{“name”:”Rated Operational Current”,”normalizedValue”:”25 A 60 °C \u003c= 440 V AC AC-3 power circuit, 40 A 60 °C \u003c= 440 V AC AC-1 power circuit”,”value”:”25 A 60 °C \u003c= 440 V AC AC-3 power circuit, 40 A 60 °C \u003c= 440 V AC AC-1 power circuit”},{“name”:”Pollution Degree”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Operating Altitude”,”normalizedValue”:”0…9842.52 ft (0…3000 m)”,”value”:”0…9842.52 ft (0…3000 m)”},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”3 hp 230/240 V at AC 60 Hz for 1 phase , 5 hp 200/208 V at AC 60 Hz for 3 phase , 2 hp 115 V at AC 60 Hz for 1 phase , 7.5 hp 230/240 V at AC 60 Hz for 3 phase , 15 hp 460/480 V at AC 60 Hz for 3 phase , 20 hp 575/600 V at AC 60 Hz for 3 phase”,”value”:”3 hp 230/240 V at AC 60 Hz for 1 phase , 5 hp 200/208 V at AC 60 Hz for 3 phase , 2 hp 115 V at AC 60 Hz for 1 phase , 7.5 hp 230/240 V at AC 60 Hz for 3 phase , 15 hp 460/480 V at AC 60 Hz for 3 phase , 20 hp 575/600 V at AC 60 Hz for 3 phase”},{“name”:”Heat Dissipation”,”normalizedValue”:”2-3 W 50/60 Hz”,”value”:”2-3 W 50/60 Hz”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”3600 cyc/h 60 °C”,”value”:”3600 cyc/h 60 °C”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG signalling circuit IEC 60947-5-1, 63 A gG \u003c= 690 V type 1 power circuit, 40 A gG \u003c= 690 V type 2 power circuit”,”value”:”10 A gG signalling circuit IEC 60947-5-1, 63 A gG \u003c= 690 V type 1 power circuit, 40 A gG \u003c= 690 V type 2 power circuit”},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10, IEC 60947-1 Annex Q category D”,”value”:”IACS E10, IEC 60947-1 Annex Q category D”},{“name”:”Power”,”normalizedValue”:”11.185515503124 KW”,”value”:”11.185515503124 KW”},{“name”:”Coil Voltage”,”normalizedValue”:”110V AC”,”value”:”110V AC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.