Description
[{“name”:”Item”,”normalizedValue”:”IEC Magnetic Contactor”,”rank”:1,”value”:”IEC Magnetic Contactor”},{“name”:”Full Load Amps-Inductive”,”normalizedValue”:”150 A”,”rank”:2,”value”:”150 A”},{“name”:”Full Load Amps-Resistive”,”normalizedValue”:”200 A”,”rank”:3,”value”:”200 A”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:4,”value”:”3″},{“name”:”Coil Volts”,”normalizedValue”:”24 V DC”,”rank”:5,”value”:”24 V DC”},{“name”:”HP @ 3 Phase – 575V”,”normalizedValue”:”125 hp”,”rank”:12,”value”:”125 hp”},{“name”:”Aux. Contact Configuration”,”normalizedValue”:”1NO, 1NC”,”rank”:13,”value”:”1NO/1NC”},{“name”:”Enclosure NEMA Rating”,”normalizedValue”:”No Enclosure”,”rank”:14,”value”:”No Enclosure”},{“name”:”Hz”,”normalizedValue”:”50/60″,”rank”:15,”value”:”50/60″},{“name”:”Height”,”normalizedValue”:”4.33 in”,”value”:”4.33 in”},{“name”:”Width”,”normalizedValue”:”4.33 in”,”value”:”4.33 in”},{“name”:”Standards”,”normalizedValue”:”BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed”,”value”:”BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed”},{“name”:”Action”,”normalizedValue”:”Non-Reversing”,”value”:”Non-Reversing”},{“name”:”Auxiliary Contact Form”,”normalizedValue”:”1NO, 1NC”,”value”:”1NO/1NC”},{“name”:”Depth”,”normalizedValue”:”5.12 in”,”value”:”5.12 in”},{“name”:”Series”,”normalizedValue”:”TeSys Deca”,”value”:”TeSys Deca”},{“name”:”NEMA Size”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”IP Rating”,”normalizedValue”:”IP20″,”value”:”IP20″},{“name”:”Thermal Amperage”,”normalizedValue”:”200 A (at 60°C Power Circuit)”,”value”:”200 A (at 60°C Power Circuit)”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”1400 A @ 440V”,”value”:”1400 A @ 440V”},{“name”:”Fuse Amps”,”normalizedValue”:”10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)”,”value”:”10 A (Signalling Circuit), 315 A (Type 1 Power Circuit), 250 A (Type 2 Power Circuit)”},{“name”:”Signalling Circuit Frequency”,”normalizedValue”:”25 to 400 Hz”,”value”:”25 to 400 Hz”},{“name”:”Rated Voltage”,”normalizedValue”:”300V DC, 1000V AC”,”value”:”1000V AC, 300V DC”},{“name”:”Mounts On”,”normalizedValue”:”Plate, Rail”,”value”:”Plate, Rail”},{“name”:”Overvoltage Category”,”normalizedValue”:”CAT III”,”value”:”CAT III”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 msec”,”value”:”1.5 ms”},{“name”:”Net Weight”,”normalizedValue”:”2.5 kg”,”value”:”2.5 kg”},{“name”:”Environmental Attributes”,”normalizedValue”:”Mercury Free, PVC Free, Pollution Degree 3″,”value”:”Mercury Free, PVC Free, Pollution Degree 3″},{“name”:”Shock Resistance”,”normalizedValue”:”15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)”,”value”:”15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)”},{“name”:”Tightening Torque”,”normalizedValue”:”1.2 Nm (Control Circuit), 12 Nm (Power Circuit)”,”value”:”1.2 Nm (Control Circuit), 12 Nm (Power Circuit)”},{“name”:”Rated Short-Time Withstand Current”,”normalizedValue”:”250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”,”value”:”250 A (at 40°C for 10 min Power Circuit), 580 A (at 40°C for 1 min Power Circuit), 1200 A (at 40°C for 10 s Power Circuit), 1400 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)”},{“name”:”Working Height”,”normalizedValue”:”Up to 9,842.52 ft”,”value”:”Up to 9842.52 ft”},{“name”:”Operating Time”,”normalizedValue”:”20 to 35 ms (Closing), 40 to 75 ms (Opening)”,”value”:”20 to 35 ms (Closing), 40 to 75 ms (Opening)”},{“name”:”Electrical Durability”,”normalizedValue”:”0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)”,”value”:”0.85 Mcycles (150 A, AC-3, Less than 440 V); 1 Mcycles (200 A, AC-1, Less than 440 V); 0.85 Mcycles (150 A, AC-3e, Less than 440 V)”},{“name”:”Max. Temperature”,”normalizedValue”:”850°C”,”value”:”850°C”},{“name”:”Mechanical Durability”,”normalizedValue”:”8 Mcycles”,”value”:”8 Mcycles”},{“name”:”Switching Current”,”normalizedValue”:”5 mA (Signalling Circuit)”,”value”:”5 mA (Signalling Circuit)”},{“name”:”Fire Rating”,”normalizedValue”:”UL 94 V1″,”value”:”UL 94 V1″},{“name”:”Insulation Resistance Range”,”normalizedValue”:”Greater Than 10 MOhms (Signalling Circuit)”,”value”:”Greater Than 10 MOhms (Signalling Circuit)”},{“name”:”Features”,”normalizedValue”:”With Integral Suppression Device”,”value”:”With Integral Suppression Device”},{“name”:”Vibration Resistance”,”normalizedValue”:”4 G (Contactor Closed), 2 G (Contactor Open)”,”value”:”4 G (Contactor Closed), 2 G (Contactor Open)”},{“name”:”Rated Insulation Volts”,”normalizedValue”:”600/690V, 600/1000V”,”value”:”600/1000V (Power Circuit), 600/690V (Signalling Circuit)”},{“name”:”Max. Operating Watts”,”normalizedValue”:”40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)”,”value”:”40 kW (at 220 to 230V AC 50/60 Hz AC-3), 75 kW (at 380 to 400V AC 50/60 Hz AC-3), 80 kW 415 to (at 440V AC 50/60 Hz AC-3), 90 kW (at 500V AC 50/60 Hz AC-3), 100 kW (at 660 to 690V AC 50/60 Hz AC-3), 75 kW (at 1000V AC 50/60 Hz AC-3), 22 kW (at 400V AC 50/60 Hz AC-4), 40 kW (at 220 to 230V AC 50/60 Hz AC-3e), 75 kW (at 380 to 400V AC 50/60 Hz AC-3e), 80 kW (at 415 to 440V AC 50/60 Hz AC-3e), 90 kW (at 500V AC 50/60 Hz AC-3e), 100 kW (at 660 to 690V AC 50/60 Hz AC-3e), 75 kW (at 1000V AC 50/60 Hz AC-3e)”},{“name”:”Switching Voltage”,”normalizedValue”:”17 V (Signalling Circuit)”,”value”:”17 V (Signalling Circuit)”},{“name”:”Operating Speed”,”normalizedValue”:”1200 cycles per hr”,”value”:”1200 cycles per hr”},{“name”:”Electrical Connection”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Includes Protective Cover”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Impulse Withstand Voltage”,”normalizedValue”:”8 kV”,”value”:”8 kV”},{“name”:”Application”,”normalizedValue”:”Motor Control, Resistive Load”,”value”:”Motor Control, Resistive Load”},{“name”:”Rated Making Capacity”,”normalizedValue”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)”,”value”:”140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 1660 A @ 440V (Power Circuit)”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”Operational DC: 0.75 to 1.2 Uc (at -40 to 55°C), 1 to 1.2 Uc (at 55 to 70°C); Drop-Out DC: 0.15 to 0.4 Uc (at -40 to 70°C)”,”value”:”Operational DC: 0.75 to 1.2 Uc (at -40 to 55°C), 1 to 1.2 Uc (at 55 to 70°C); Drop-Out DC: 0.15 to 0.4 Uc (at -40 to 70°C)”},{“name”:”Impedance”,”normalizedValue”:”0.6 mOhm”,”value”:”0.6 mOhm”},{“name”:”Coil Voltage”,”normalizedValue”:”24 V DC”,”value”:”24 V DC”},{“name”:”Horsepower @ Single Phase – 240V AC”,”normalizedValue”:”3 HP”,”value”:”3 hp”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Embedded Surge Suppressor”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”Full Load Current – Resistive”,”normalizedValue”:”200 A”,”value”:”200 A”},{“name”:”Overall Depth”,”normalizedValue”:”5.35 in”,”value”:”5.35 in”},{“name”:”Overall Width”,”normalizedValue”:”0.47 in”,”value”:”0.47 in”},{“name”:”Horsepower @ Three Phase – 600V AC”,”normalizedValue”:”125 HP”,”value”:”125 hp”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail, Plate”,”value”:”DIN Rail, Plate”},{“name”:”Horsepower @ Three Phase – 240V AC”,”normalizedValue”:”50 HP”,”value”:”50 hp”},{“name”:”Electrical Operating Durability”,”normalizedValue”:”1,000,000, 850,000″,”value”:”1,000,000, 850,000″},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”No Enclosure”,”value”:”No Enclosure”},{“name”:”Contactor Style”,”normalizedValue”:”IEC”,”value”:”IEC”},{“name”:”Number of Auxillary Contacts”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Overall Height”,”normalizedValue”:”6.22 in”,”value”:”6.22 in”},{“name”:”Horsepower @ Three Phase – 480V AC”,”normalizedValue”:”100 HP”,”value”:”100 hp”},{“name”:”Terminal Connection Type”,”normalizedValue”:”Screw Clamp Terminals”,”value”:”Screw Clamp Terminals”},{“name”:”Resistance Properties”,”normalizedValue”:”Fire Resistant, Insulation Resistant”,”value”:”Fire Resistant, Insulation Resistant”},{“name”:”Full Load Current – Inductive”,”normalizedValue”:”150 A”,”value”:”150 A”},{“name”:”Reversing Capability”,”normalizedValue”:”Non-Reversing”,”value”:”Non-Reversing”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Includes Auxiliary Contacts”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Enclosure Material”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Horsepower @ Three Phase – 208V AC”,”normalizedValue”:”40 HP”,”value”:”40 hp”},{“name”:”Maximum Voltage Rating”,”normalizedValue”:”1,000 V AC”,”value”:”1000V AC”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Number of Normally Open Main Contacts”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”8,000,000″,”value”:”8,000,000″},{“name”:”Power Dissipation Per Pole”,”normalizedValue”:”24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e”,”value”:”24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e”},{“name”:”Average Impedance”,”normalizedValue”:”0.6 mOhm – Ith 200 A 50 Hz for power circuit”,”value”:”0.6 mOhm – Ith 200 A 50 Hz for power circuit”},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC”,”value”:”Power circuit Less than or Equal to 1000 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC”},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1660 A at 440 V for power circuit conforming to IEC 60947″,”value”:”140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1660 A at 440 V for power circuit conforming to IEC 60947″},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA (for signalling circuit)”,”value”:”5 mA for signalling circuit”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V for signalling circuit”,”value”:”17 V for signalling circuit”},{“name”:”Safety Reliability Level”,”normalizedValue”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″,”value”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP20 front face IEC 60529″,”value”:”IP20 front face IEC 60529″},{“name”:”Product Certifications”,”normalizedValue”:”UL; BV; GL; GOST; CSA; CCC; LROS (Lloyds register of shipping); RINA; DNV; UKCA; CE”,”value”:”UL; BV; GL; GOST; CSA; CCC; LROS (Lloyds register of shipping); RINA; DNV; UKCA; CE”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”1200 cyc/h 140°F (60°C)”,”value”:”1200 cyc/h 140°F (60°C)”},{“name”:”Compatibility Code”,”normalizedValue”:”LC1D”,”value”:”LC1D”},{“name”:”Mechanical Robustness”,”normalizedValue”:”Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)”,”value”:”Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 6 Gn for 11 ms)”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL”,”value”:”Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL”},{“name”:”Permissible Ambient Air Temperature Around The Device”,”normalizedValue”:”-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating”,”value”:”-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating”},{“name”:”Pollution Degree”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Contactor Application”,”normalizedValue”:”Resistive load”,”value”:”Resistive load; Motor control”},{“name”:”Product Or Component Type”,”normalizedValue”:”Contactor”,”value”:”Contactor”},{“name”:”Auxiliary Contacts Type”,”normalizedValue”:”Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1″,”value”:”Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1″},{“name”:”Utilisation Category”,”normalizedValue”:”AC-3; AC-4; AC-1; AC-3e”,”value”:”AC-3; AC-4; AC-1; AC-3e”},{“name”:”Contact Compatibility”,”normalizedValue”:”M10″,”value”:”M10″},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Connections – Terminals”,”normalizedValue”:”Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: solid without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) – cable stiffness: solid without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) – cable stiffness: solid without cable end”,”value”:”Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: solid without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 1 0.02 to 0.19 in² (10 to 120 mm²) – cable stiffness: solid without cable end; Power circuit: connector 2 0.02 to 0.08 in² (10 to 50 mm²) – cable stiffness: solid without cable end”},{“name”:”Mounting Support”,”normalizedValue”:”Rail”,”value”:”Rail; Plate”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”200 A (at 140°F (60°C)) for power circuit”,”value”:”200 A (at 140°F (60°C)) for power circuit”},{“name”:”Protective Treatment”,”normalizedValue”:”THIEC 60068-2-30″,”value”:”THIEC 60068-2-30″},{“name”:”Rated Short Time Withstand Current”,”normalizedValue”:”250 A 104°F (40°C) – 10 min for power circuit; 580 A 104°F (40°C) – 1 min for power circuit; 1200 A 104°F (40°C) – 10 s for power circuit; 1400 A 104°F (40°C) – 1 s for power circuit; 100 A – 1 s for signalling circuit; 120 A – 500 ms for signalling circuit; 140 A – 100 ms for signalling circuit”,”value”:”250 A 104°F (40°C) – 10 min for power circuit; 580 A 104°F (40°C) – 1 min for power circuit; 1200 A 104°F (40°C) – 10 s for power circuit; 1400 A 104°F (40°C) – 1 s for power circuit; 100 A – 1 s for signalling circuit; 120 A – 500 ms for signalling circuit; 140 A – 100 ms for signalling circuit”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV IEC 60947″,”value”:”8 kV IEC 60947″},{“name”:”Rated Operational Current”,”normalizedValue”:”200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit”,”value”:”200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 150 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit”},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm for signalling circuit”,”value”:”Greater than 10 MOhm for signalling circuit”},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10 exposure to damp heat”,”value”:”IACS E10 exposure to damp heat”},{“name”:”Operating Altitude”,”normalizedValue”:”0 to 9842.52 ft (0 to 3000 m)”,”value”:”0 to 9842.52 ft (0 to 3000 m)”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG for signalling circuit conforming to IEC 60947-5-1; 315 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 250 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”,”value”:”10 A gG for signalling circuit conforming to IEC 60947-5-1; 315 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 250 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”},{“name”:”Hold-In Power Consumption in W”,”normalizedValue”:”2.4 to 5.1 W 68°F (20°C)”,”value”:”2.4 to 5.1 W 68°F (20°C)”},{“name”:”Control Circuit Type”,”normalizedValue”:”DC standard”,”value”:”DC standard”},{“name”:”Inrush Power in W”,”normalizedValue”:”270 to 365 W 68°F (20°C))”,”value”:”270 to 365 W 68°F (20°C))”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94″,”value”:”V1 conforming to UL 94″},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”40 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors”,”value”:”40 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors”},{“name”:”Fire Resistance”,”normalizedValue”:”1562°F IEC 60695-2-1″,”value”:”1562°F (850°C) IEC 60695-2-1″},{“name”:”Motor Power KW”,”normalizedValue”:”40 kW at 220 to 230 V AC 50/60 Hz (AC-3); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 400 V AC 50/60 Hz (AC-4); 40 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e)”,”value”:”40 kW at 220 to 230 V AC 50/60 Hz (AC-3); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 22 kW at 400 V AC 50/60 Hz (AC-4); 40 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 75 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 80 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 100 kW at 660 to 690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e)”},{“name”:”Protective Cover”,”normalizedValue”:”With”,”value”:”With”},{“name”:”Time Constant”,”normalizedValue”:”25 msec”,”value”:”25 ms”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Czechia”,”value”:”Czechia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.