Description
[{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:1,”value”:”Solenoid Valve”},{“name”:”Voltage”,”normalizedValue”:”110V, 120V”,”rank”:2,”value”:”110V, 120V”},{“name”:”Standards”,”normalizedValue”:”CSA Certified, EN 161 Class A, FM Approved, RoHS, UL Listed”,”value”:”CSA Certified, EN 161 Class A, FM Approved, RoHS, UL Listed”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Body Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Wattage”,”normalizedValue”:”240 VA”,”value”:”240 VA”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Overall Length”,”normalizedValue”:”5 3/16 in”,”value”:”5 3/16 in”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Ambient Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Mounting Orientation”,”normalizedValue”:”Vertical, Horizontal”,”value”:”Horizontal or Vertical”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”150 deg F”,”value”:”150 Degrees F”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Environmental Rating”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Overall Width”,”normalizedValue”:”5-3/16 in”,”value”:”5 3/16 in”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Overall Height”,”normalizedValue”:”8-11/16 in”,”value”:”8 11/16 in”},{“name”:”For Media”,”normalizedValue”:”Gases”,”value”:”Gases”},{“name”:”Coil Enclosure”,”normalizedValue”:”Watertight”,”value”:”Watertight”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Compatible with Series”,”normalizedValue”:”158/V710″,”value”:”158/V710″},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Configurable”,”value”:”Configurable”},{“name”:”Coil Insulation Class”,”normalizedValue”:”A”,”value”:”A”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”20 psi”,”value”:”20 psi”},{“name”:”Compatible with Brand”,”normalizedValue”:”ASCO”,”value”:”ASCO”},{“name”:”Application”,”normalizedValue”:”Boilers, Dryers, Furnaces, Heating Systems, Incinerators, Ovens, Thermal Oxidizers”,”value”:”Boilers, Dryers, Furnaces, Heating Systems, Incinerators, Ovens, Thermal Oxidizers”},{“name”:”Response Time”,”normalizedValue”:”1 sec”,”value”:”1 sec”},{“name”:”Product Type”,”normalizedValue”:”Actuator”,”value”:”Motorized Actuator”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.