UPS System, 900VA, Line Interactive, Out: 110/115/120V AC In: 120V AC

$201,99

UPS System, Line Interactive, Power Rating 900 VA, Wattage 475 W, Input Voltage 120V AC, Output Voltage 115V AC, 120V AC, Backup Time (Half/Full Load) 10 min/3 min, Mounting Tower, Outlet Type (4) Surge, (4) UPS/Surge, Number of Outlets 8, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 2 to 4 msec, Width 4 in, Depth 7 in, Height 12 in, Cord Length 6 ft

9999 in stock

SKU: GRG0921672 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”900 VA”,”rank”:4,”value”:”900VA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”475 W”,”rank”:6,”value”:”475 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V AC”,”rank”:8,”value”:”110/115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”10 min/3 min”,”rank”:9,”value”:”10 min/3 min”},{“name”:”Outlet Type”,”normalizedValue”:”(4) Surge; (4) UPS/Surge”,”rank”:10,”value”:”(4) Surge; (4) UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”8″,”rank”:12,”value”:”8″},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”900 VA”,”value”:”900.0 VA”},{“name”:”Footnotes”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Depth”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Special Features”,”normalizedValue”:”Automatic Voltage Regulation Conditions Power Through Brownouts, LCD Display Indicates Input Voltage, Battery Capacity And A Variety Of Operating Conditions, Poweralert Software”,”value”:”Automatic Voltage Regulation Conditions Power Through Brownouts, LCD Display Indicates Input Voltage, Battery Capacity And A Variety Of Operating Conditions, Poweralert Software”},{“name”:”Includes”,”normalizedValue”:”UPS System”,”value”:”UPS System”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Ports”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”Width”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Input Current”,”normalizedValue”:”12 A”,”value”:”12 A”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Standards”,”normalizedValue”:”CSA, FCC Part 15 Class B, NOM, RoHS, UL1778″,”value”:”CSA, FCC Part 15 Class B, NOM, RoHS, UL1778″},{“name”:”Height”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(8) 5-15R”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Overall Height”,”normalizedValue”:”11.8 in”,”value”:”11.8 in”},{“name”:”Overall Width”,”normalizedValue”:”3.7 in”,”value”:”3.7 in”},{“name”:”Housing Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Operating Temp. Range”,”normalizedValue”:”122\u0026deg;F (50\u0026deg;C)”,”value”:”122\u0026deg;F (50\u0026deg;C)”},{“name”:”Capacity – Batteries”,”normalizedValue”:”900 VA/475 W”,”value”:”900 VA/475 W”},{“name”:”Input Connection”,”normalizedValue”:”6 ft Cord with NEMA 5-15P Plug”,”value”:”6 ft Cord with NEMA 5-15P Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”ABS”,”value”:”ABS”},{“name”:”Communications Cable”,”normalizedValue”:”User supplies USB cable”,”value”:”User supplies USB cable”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery status; alarm can be disabled using PowerAlert software”,”value”:”Audible alarm indicates power-failure and low-battery status; alarm can be disabled using PowerAlert software”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”183″,”value”:”183″},{“name”:”Hot-Swap PDU options”,”normalizedValue”:”PDUB15 (2U / 8 5-15R outlets)”,”value”:”PDUB15 (2U / 8 5-15R outlets)”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing”,”value”:”Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”139″,”value”:”139″},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”300″,”value”:”300″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 89 and 104 are boosted by 14%”,”value”:”Input voltages between 89 and 104 are boosted by 14%”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89″},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”870″,”value”:”870″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”12 A”,”value”:”12A”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 16 hours from 10% to 90%”,”value”:”Less than 16 hours from 10% to 90%”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”11.8 x 3.7 x 7.2″,”value”:”11.8 x 3.7 x 7.2″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”10 min”,”value”:”10 min. (240w)”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”3 min”,”value”:”3 min. (475w)”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”61″,”value”:”61″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC51″,”value”:”RBC51″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”LED Indicators”,”normalizedValue”:”Front panel LCD display”,”value”:”Front panel LCD display”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”475″,”value”:”475″},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”485″,”value”:”485″},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Load Capacity”,”normalizedValue”:”900 VA/475 W”,”value”:”900 VA/475 W”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert software”,”value”:”PowerAlert software”},{“name”:”Surge Energy Rating”,”normalizedValue”:”870 J”,”value”:”870 J”},{“name”:”Battery Life”,”normalizedValue”:”6 yr”,”value”:”6 Year”},{“name”:”Alarm”,”normalizedValue”:”AC Input Failure”,”value”:”AC Input Failure”},{“name”:”Additional Information”,”normalizedValue”:”Low voltage transfer to battery power: Switches to battery power as line voltage decreases to 89V or less, switches back to AC mode as line voltage increases to 94V or higher, High voltage transfer to battery power: Switches to battery mode as line voltage increases to 139V or higher, switches back to AC mode as line voltage decreases to 135V or lower, Network monitoring port: Single built-in USB port supports on battery, low battery and power restored messaging. Interface supports timed inverter shutoff after unattended shutdown. Compatible with Tripp Lite’s PowerAlert and Watchdog service software, Compatible with Tripp Lite’s Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment ideal for unattended kiosk applications, Switches: Includes 2 front panel switches – one main on/off power switch and one dual function \”alarm cancel\” / \”self test\” button, Entry-level PCs, networked workstations, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems. Ideal for sensitive electronic applications in areas where brownout conditions are common”,”value”:”Low voltage transfer to battery power: Switches to battery power as line voltage decreases to 89V or less, switches back to AC mode as line voltage increases to 94V or higher, High voltage transfer to battery power: Switches to battery mode as line voltage increases to 139V or higher, switches back to AC mode as line voltage decreases to 135V or lower, Network monitoring port: Single built-in USB port supports on battery, low battery and power restored messaging. Interface supports timed inverter shutoff after unattended shutdown. Compatible with Tripp Lite’s PowerAlert and Watchdog service software, Compatible with Tripp Lite’s Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment ideal for unattended kiosk applications, Switches: Includes 2 front panel switches – one main on/off power switch and one dual function \”alarm cancel\” / \”self test\” button, Entry-level PCs, networked workstations, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems. Ideal for sensitive electronic applications in areas where brownout conditions are common”},{“name”:”Package Contents”,”normalizedValue”:”OmniSmart OMNI900LCD 900 VA Tower UPS, Manual with Warranty Information”,”value”:”OmniSmart OMNI900LCD 900 VA Tower UPS, Manual with Warranty Information”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Waveform Type”,”normalizedValue”:”Pulse-width Modulated Sine Wave”,”value”:”Pulse-width Modulated Sine Wave”},{“name”:”Status Indicators”,”normalizedValue”:”Front panel LCD screen with blue backlight offers: Continuous input line voltage data, UPS status information on line power status, Battery power status, Battery charge level, Voltage regulation operation”,”value”:”Front panel LCD screen with blue backlight offers: Continuous input line voltage data, UPS status information on line power status, Battery power status, Battery charge level, Voltage regulation operation”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122°F”,”value”:”122°F (50°C)”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”20 hr”,”value”:”20 Hour”},{“name”:”Package Includes”,”normalizedValue”:”OMNI900LCD UPS System;Instruction manual”,”value”:”OMNI900LCD UPS System;Instruction manual”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”475″,”value”:”475″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”,”value”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”},{“name”:”UPS Applications”,”normalizedValue”:”Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality”,”value”:”Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Overall Depth”,”normalizedValue”:”7.2 in”,”value”:”7.2 in”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Power Outage”,”value”:”Low Battery, Power Outage”},{“name”:”Input Current – Maximum”,”normalizedValue”:”12 A”,”value”:”12 A”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Output Ports Included”,”normalizedValue”:”USB”,”value”:”USB”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Data Line Protection”,”normalizedValue”:”No Data Line Surge Protection”,”value”:”No Data Line Surge Protection”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”3 yr (Limited)”,”value”:”3 yr Limited”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Battery Recharge Time”,”normalizedValue”:”16 hr”,”value”:”16 hr”},{“name”:”Power Rating – Real”,”normalizedValue”:”475 W”,”value”:”475 W”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”RBC51″,”value”:”RBC51″},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Power Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Visible Indicator Light Conditions”,”normalizedValue”:”Overload, Replace Battery”,”value”:”Overload, Replace Battery”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 900VA, Line Interactive, Out: 110/115/120V AC In: 120V AC”