Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Double Conversion”,”rank”:3,”value”:”Online Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”6 kVA”,”rank”:4,”value”:”6kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”5.4 kW”,”rank”:6,”value”:”5.4 kW”},{“name”:”Input Voltage”,”normalizedValue”:”200 V AC, 208 V AC, 240 V AC”,”rank”:7,”value”:”200 V AC, 208 V AC, 240 V AC”},{“name”:”Output Voltage”,”normalizedValue”:”200 V, 208 V, 240 V”,”rank”:8,”value”:”200 V, 208 V, 240 V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”8.5 min/2 min”,”rank”:9,”value”:”8.5 min/2 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”Not Medical Grade Approved”,”rank”:11,”value”:”Not Medical Grade Approved”},{“name”:”Number of Outlets”,”normalizedValue”:”4″,”rank”:12,”value”:”4″},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”6 kVA”,”value”:”6.0 kVA”},{“name”:”Width”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-20R, L6-30R”,”value”:”L6-20R, L6-30R”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”value”:”UPS/Surge”},{“name”:”Includes”,”normalizedValue”:”(4) Post Rackmount Installation Hardware, SUPDMB6K Detachable PDU with Maintenance Bypass Switch, USB, DB9 and EPO Cables”,”value”:”(4) Post Rackmount Installation Hardware, SUPDMB6K Detachable PDU with Maintenance Bypass Switch, USB, DB9 and EPO Cables”},{“name”:”Input Current”,”normalizedValue”:”31.9 A”,”value”:”31.9 A”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”200V AC, 208V AC, 240V AC”,”value”:”200V AC, 208V AC, 240V AC”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack”,”value”:”Rack”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”200V AC, 208V AC, 240V AC”,”value”:”200V AC, 208V AC, 240V AC”},{“name”:”Height”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L6-30P”,”value”:”L6-30P”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), IEC 61000, RoHS, UL1778″},{“name”:”Watts”,”normalizedValue”:”5,400″,”value”:”5.4kW”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”5.4 kW”,”value”:”5.4 kW”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Depth”,”normalizedValue”:”21 in”,”value”:”21 in”},{“name”:”Overall Height”,”normalizedValue”:”6.85 in”,”value”:”6.85 in”},{“name”:”Overall Width”,”normalizedValue”:”17.52 in”,”value”:”17.52 in”},{“name”:”Input Connection”,”normalizedValue”:”NEMA L6-30P Plug”,”value”:”NEMA L6-30P Plug”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Type”,”normalizedValue”:”Lead Acid”,”value”:”Valve Regulated Lead Acid (VRLA)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Runtime is expandable with external battery packs”,”value”:”Runtime is expandable with external battery packs”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered”,”value”:”20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”2,279″,”value”:”2279″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Rack Height”,”normalizedValue”:”4 U”,”value”:”4U”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”174″,”value”:”174″},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”20.7″,”value”:”20.7″},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”30A”,”value”:”30A”},{“name”:”Switches”,”normalizedValue”:”Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.”,”value”:”Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.”},{“name”:”Output Receptacles”,”normalizedValue”:”L6-30R, L6-20R”,”value”:”(2) L6-20R; (2) L6-30R”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”,”value”:”Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”Factory configured to 208V”,”value”:”Factory configured to 208V”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”6.85 x 17.5 x 20.67″,”value”:”6.85 x 17.5 x 20.67″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC5-192″,”value”:”RBC5-192″},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-3000 m”,”value”:”0-3000 m”},{“name”:”Output Capacity Details”,”normalizedValue”:”Output capacity de-rates to 4992 watts when used at 208V nominal; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared”,”value”:”Output capacity de-rates to 4992 watts when used at 208V nominal; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH”,”value”:”BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”6,000″,”value”:”6000″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”8 min 30 sec”,”value”:”8.5 minutes (2700 watts)”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”200 V AC, 208 V AC, 240 V AC”,”value”:”200V AC; 208V AC; 240V AC”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”768″,”value”:”768″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,767″,”value”:”1767″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”280V (full load) / 300V (90% load or less)”,”value”:”280V (full load) / 300V (90% load or less)”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”525″,”value”:”525″},{“name”:”Audible Noise”,”normalizedValue”:”60 dBA at front side 1 meter”,”value”:”60 dBA at front side 1 meter”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Includes 4 post rackmount installation accessories”,”value”:”Includes 4 post rackmount installation accessories”},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”25.67″,”value”:”25.67″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”2 minutes (5400 watts)”,”value”:”2 minutes (5400 watts)”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)”,”value”:”Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”L6-30P”,”value”:”L6-30P”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”,”value”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fans”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)”,”value”:”31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltages as high as 300V (\u003c90% load) and 280V (full load)”,”value”:”Corrects overvoltages as high as 300V (\u003c90% load) and 280V (full load)”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”Voltage selection via front panel LCD interface”,”value”:”Voltage selection via front panel LCD interface”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”445″,”value”:”445″},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Output Receptacle Details”,”normalizedValue”:”Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement”,”value”:”Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable internal batteries”,”value”:”Hot-swappable, user replaceable internal batteries”},{“name”:”Frequency Compatibility”,”normalizedValue”:”50 / 60 Hz”,”value”:”50 / 60 Hz”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”6 hours from 10% to 90% (typical, full load discharge)”,”value”:”6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”156V (full load) / 100V (50% load or less, derates linearly)”,”value”:”156V (full load) / 100V (50% load or less, derates linearly)”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects undervoltages as low as 100 (\u003c50% load) and 155V (full load); derates linearly”,”value”:”Corrects undervoltages as low as 100 (\u003c50% load) and 155V (full load); derates linearly”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,595″,”value”:”2595″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0-3000m (0 to 10,000 ft.)”,”value”:”0-3000m (0 to 10,000 ft.)”},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”192″,”value”:”192″},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”200 V, 208 V, 240 V”,”value”:”200V; 208V; 240V”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”28.67″,”value”:”28.67″},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”5.4″,”value”:”5.4″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”5,400″,”value”:”5400″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Transfer Time (Economy Mode)”,”normalizedValue”:”8 ms. typical power failure response in optional economy mode”,”value”:”8 ms. typical power failure response in optional economy mode”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Certifications \u0026 Standards”,”normalizedValue”:”UL1778, CSA, FCC Part 15 Category A (EMI), IEC 61000-4-5 1995 B Surge Immunity”,”value”:”UL1778, CSA, FCC Part 15 Category A (EMI), IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”Sound Emission (A-Weighted)”,”normalizedValue”:”60 dB”,”value”:”60 dB(A)”},{“name”:”Storage Temperature”,”normalizedValue”:”5°F (-15°C) – 122°F (50°C)”,”value”:”5°F (-15°C) – 122°F (50°C)”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 Hour”},{“name”:”Product Line”,”normalizedValue”:”SmartOnline”,”value”:”SmartOnline”},{“name”:”Status Indicators”,”normalizedValue”:”LEDs: Line power, Online mode, Economy/bypass mode, On-battery, Charger, AC output”,”value”:”LEDs: Line power, Online mode, Economy/bypass mode, On-battery, Charger, AC output”},{“name”:”Product Name”,”normalizedValue”:”SmartOnline EZ SU6000RT4UHV 6000 VA Tower/Rack Mountable UPS”,”value”:”SmartOnline EZ SU6000RT4UHV 6000 VA Tower/Rack Mountable UPS”},{“name”:”EPO Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Waveform Type”,”normalizedValue”:”Pure Sine Wave”,”value”:”Pure Sine Wave”},{“name”:”EMI/RFI Noise Filter”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”2 Minute”,”value”:”2 Minute”},{“name”:”Product Series”,”normalizedValue”:”EZ”,”value”:”EZ”},{“name”:”Energy Saving”,”normalizedValue”:”High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation”,”value”:”High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Frequency”,”normalizedValue”:”50 Hz”,”value”:”50 Hz”},{“name”:”Receptacle Detail”,”normalizedValue”:”2 x NEMA L6-30R, 2 x NEMA L6-20R”,”value”:”2 x NEMA L6-30R, 2 x NEMA L6-20R”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Type”,”normalizedValue”:”Double Conversion Online UPS”,”value”:”Double Conversion Online UPS”},{“name”:”Input Frequency”,”normalizedValue”:”50 Hz”,”value”:”50 Hz”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic, Manual”,”value”:”Manual, Automatic”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Surge Energy Rating”,”normalizedValue”:”2595 J”,”value”:”2595 J”},{“name”:”DC System Voltage”,”normalizedValue”:”192 V DC”,”value”:”192 V DC”},{“name”:”Maximum Operating Elevation”,”normalizedValue”:”9,842.52 ft”,”value”:”9842.52 ft”},{“name”:”Load Capacity”,”normalizedValue”:”6000 VA/5400 W”,”value”:”6000 VA/5400 W”},{“name”:”Plug/Connector Type”,”normalizedValue”:”NEMA L6-30P”,”value”:”NEMA L6-30P”},{“name”:”USB (HID Compliant) Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline EZ SU6000RT4UHV 6000 VA Tower/Rack Mountable UPS, PowerAlert Software Suite CD, USB Cable, Serial Cable, EPO Cable, Rail Kit”,”value”:”SmartOnline EZ SU6000RT4UHV 6000 VA Tower/Rack Mountable UPS, PowerAlert Software Suite CD, USB Cable, Serial Cable, EPO Cable, Rail Kit”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Replaceable Battery”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104°F”,”value”:”104°F (40°C)”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software Suite”,”value”:”PowerAlert Software Suite”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”8 min 30 sec”,”value”:”8.50 Minute”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”6.85 x 17.5 x 20.67″,”value”:”6.850 x 17.500 x 20.670″},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); UL 1778″,”value”:”IEC 61000; CSA (Canada); UL 1778″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”2 min”,”value”:”2 min. (5400W)”},{“name”:”Package Includes”,”normalizedValue”:”SU6000RT4UHVPM Power Module;SUPDMB6K Detachable PDU with Maintenance Bypass Switch;USB, DB9 and EPO cables;4 post rackmount installation hardware”,”value”:”SU6000RT4UHVPM Power Module;SUPDMB6K Detachable PDU with Maintenance Bypass Switch;USB, DB9 and EPO cables;4 post rackmount installation hardware”},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”6,000″,”value”:”6000″},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”1,767″,”value”:”1767″},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”8 min 30 sec”,”value”:”8.5 min. (2700W)”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”2,279″,”value”:”2279″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”5,400″,”value”:”5400″},{“name”:”Surge Suppression Rating”,”normalizedValue”:”2,595 J”,”value”:”2,595 J”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”RBC5-192″,”value”:”RBC5-192″},{“name”:”Run Time – Full Load”,”normalizedValue”:”2 min”,”value”:”2 min”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Receptacle Configuration”,”normalizedValue”:”L6-30R, L6-20R”,”value”:”L6-20R, L6-30R”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Transfer Time – Maximum”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Input Current – Minimum”,”normalizedValue”:”26.6 A”,”value”:”26.6 A”},{“name”:”Power Rating – Apparent”,”normalizedValue”:”6 kVA”,”value”:”6 kVA”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Plug Configuration”,”normalizedValue”:”L6-30P”,”value”:”L6-30P”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Power Rating – Real”,”normalizedValue”:”5.4 kW”,”value”:”5.4 kW”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Number of Outlets – UPS”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Overall Depth”,”normalizedValue”:”20.67 in”,”value”:”20.67 in”},{“name”:”Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 hr”},{“name”:”Run Time – Half Load”,”normalizedValue”:”8 min 30 sec”,”value”:”8.5 min”},{“name”:”Input Current – Maximum”,”normalizedValue”:”31.9 A”,”value”:”31.9 A”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP192V12-3U, BP192V5RT2U, BP192V787C-1PH”,”value”:”BP192V12-3U, BP192V5RT2U, BP192V787C-1PH”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.