UPS System, 650VA, Line Interactive, Out: 110/115/120V AC In: 120V AC

$201,99

UPS System, Line Interactive, Power Rating 650 VA, Wattage 350 W, Input Voltage 120V AC, Output Voltage 115V AC, 120V AC, Backup Time (Half/Full Load) 12 min/3.5 min, Mounting Tower, Outlet Type (4) Surge, (4) UPS/Surge, Number of Outlets 8, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 4 msec, Width 4 in, Depth 7 in, Height 12 in, Cord Length 6 ft

9999 in stock

SKU: GRG4261887 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”650 VA”,”rank”:4,”value”:”650VA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”350 W”,”rank”:6,”value”:”350 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V AC”,”rank”:8,”value”:”110/115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”12 min/3.2 min”,”rank”:9,”value”:”12 min/3.2 min”},{“name”:”Outlet Type”,”normalizedValue”:”(4) Surge; (4) UPS/Surge”,”rank”:10,”value”:”(4) Surge; (4) UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”8″,”rank”:12,”value”:”8″},{“name”:”Input Current”,”normalizedValue”:”12 A”,”value”:”12 A”},{“name”:”Height”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(8) 5-15R”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Transfer Time”,”normalizedValue”:”4 msec”,”value”:”4 msec”},{“name”:”Footnotes”,”normalizedValue”:”4″,”value”:”4″},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”650 VA”,”value”:”650.0 VA”},{“name”:”Includes”,”normalizedValue”:”UPS System”,”value”:”UPS System”},{“name”:”Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Depth”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Ports”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Width”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Special Features”,”normalizedValue”:”USB Port And Poweralert Software Enables Unattended Shutdown In Case Of Extended Power Failure”,”value”:”USB Port And Poweralert Software Enables Unattended Shutdown In Case Of Extended Power Failure”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Standards”,”normalizedValue”:”CSA, FCC Part 15 Class B, NOM, RoHS, UL1778″,”value”:”CSA, FCC Part 15 Class B, NOM, RoHS, UL1778″},{“name”:”Overall Height”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”Overall Width”,”normalizedValue”:”3.7 in”,”value”:”3.7 in”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Operating Temp. Range”,”normalizedValue”:”122°F (50°C)”,”value”:”122°F (50°C)”},{“name”:”Capacity – Batteries”,”normalizedValue”:”650 VA/350 W”,”value”:”650 VA/350 W”},{“name”:”Housing Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Input Connection”,”normalizedValue”:”6 ft Cord with NEMA 5-15P Plug”,”value”:”6 ft Cord with NEMA 5-15P Plug”},{“name”:”Housing Material”,”normalizedValue”:”ABS”,”value”:”ABS”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”139″,”value”:”139″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 20 hours from 10 to 90%”,”value”:”Less than 20 hours from 10 to 90%”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”12 x 3.7 x 7.2″,”value”:”12 x 3.7 x 7.2″},{“name”:”Communications Cable”,”normalizedValue”:”User supplies USB cable”,”value”:”User supplies USB cable”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”650″,”value”:”650″},{“name”:”Cooling Method”,”normalizedValue”:”Convection”,”value”:”Convection”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing”,”value”:”Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC51″,”value”:”RBC51″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 89 and 104 are boosted by 14%”,”value”:”Input voltages between 89 and 104 are boosted by 14%”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”31″,”value”:”31″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”350″,”value”:”350″},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”442″,”value”:”442″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”305″,”value”:”305″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”183″,”value”:”183″},{“name”:”Hot-Swap PDU options”,”normalizedValue”:”PDUB15 (2U / 8 5-15R outlets)”,”value”:”PDUB15 (2U / 8 5-15R outlets)”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”3 min 12 sec”,”value”:”3.2 min. (350w)”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89″},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”12 A”,”value”:”12A”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”480″,”value”:”480″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min”,”value”:”12 min. (175w)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery status; alarm can be disabled using PowerAlert software”,”value”:”Audible alarm indicates power-failure and low-battery status; alarm can be disabled using PowerAlert software”},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”LED Indicators”,”normalizedValue”:”Front panel LCD display”,”value”:”Front panel LCD display”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 Hour”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122°F”,”value”:”122°F (50°C)”},{“name”:”Alarm”,”normalizedValue”:”Self-test Operation”,”value”:”Self-test Operation”},{“name”:”Protection Type”,”normalizedValue”:”Brownout”,”value”:”Brownout”},{“name”:”Waveform Type”,”normalizedValue”:”Pulse-width Modulated Sine Wave”,”value”:”Pulse-width Modulated Sine Wave”},{“name”:”Load Capacity”,”normalizedValue”:”650 VA/350 W”,”value”:”650 VA/350 W”},{“name”:”Status Indicators”,”normalizedValue”:”Input Voltage : Shows actual incoming voltage in real time, Battery Charge : Shows approximate charge available on the battery, Automatic Voltage Regulation (AVR) : Illuminates to indicate the UPS is automatically regulating incoming voltage without draining battery power, Battery Recharge/Replace : Illuminates to indicate the UPS batteries need to be recharged or replaced (following a self-test), Battery Backup : Illuminates to indicate that the UPS is supplying battery power to connected equipment, Output Load Level : Illuminates when the electrical load of connected equipment exceeds the capacity of the UPS”,”value”:”Input Voltage : Shows actual incoming voltage in real time, Battery Charge : Shows approximate charge available on the battery, Automatic Voltage Regulation (AVR) : Illuminates to indicate the UPS is automatically regulating incoming voltage without draining battery power, Battery Recharge/Replace : Illuminates to indicate the UPS batteries need to be recharged or replaced (following a self-test), Battery Backup : Illuminates to indicate that the UPS is supplying battery power to connected equipment, Output Load Level : Illuminates when the electrical load of connected equipment exceeds the capacity of the UPS”},{“name”:”Surge Energy Rating”,”normalizedValue”:”480 J”,”value”:”480 J”},{“name”:”Package Contents”,”normalizedValue”:”OmniSmart 650 VA Digital UPS, OMNI650LCD Digital UPS System, Manual with warranty information”,”value”:”OmniSmart 650 VA Digital UPS, OMNI650LCD Digital UPS System, Manual with warranty information”},{“name”:”Assembly Required”,”normalizedValue”:”No”,”value”:”No”},{“name”:”UPS Applications”,”normalizedValue”:”Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality”,”value”:”Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”650″,”value”:”650″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”,”value”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”},{“name”:”Package Includes”,”normalizedValue”:”OMNI650LCD UPS System;Instruction manual”,”value”:”OMNI650LCD UPS System;Instruction manual”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”4.7 x 3.66 x 7.24″,”value”:”4.700 x 3.660 x 7.240″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”350″,”value”:”350″},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”RBC51″,”value”:”RBC51″},{“name”:”Power Rating – Real”,”normalizedValue”:”350 W”,”value”:”350 W”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”3 yr (Limited)”,”value”:”3 yr Limited”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Overall Depth”,”normalizedValue”:”7.2 in”,”value”:”7.2 in”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Data Line Protection”,”normalizedValue”:”No Data Line Surge Protection”,”value”:”No Data Line Surge Protection”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Power Outage”,”value”:”Low Battery, Power Outage”},{“name”:”Output Ports Included”,”normalizedValue”:”USB”,”value”:”USB”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Power Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Visible Indicator Light Conditions”,”normalizedValue”:”Overload, Replace Battery”,”value”:”Overload, Replace Battery”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Input Current – Maximum”,”normalizedValue”:”12 A”,”value”:”12 A”},{“name”:”Battery Recharge Time”,”normalizedValue”:”20 hr”,”value”:”20 hr”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 650VA, Line Interactive, Out: 110/115/120V AC In: 120V AC”