UPS System, 5kVA, Online Double Conversion, Out: 120 V, 208 V In: 208 V AC

$4887,99

UPS System, Online Double Conversion, Power Rating 5 kVA, Wattage 4.5 kW, Input Voltage 208V AC, Output Voltage 120V AC, 208V AC, Backup Time (Half/Full Load) 11 min/3.5 min, Mounting Rack, Outlet Type UPS/Surge, Number of Outlets 16, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15/20R, L6-20R, L6-30R, NEMA Plug Configuration L6-30P, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 0 msec, Width 18 in, Depth 21 in, Height 7 in

Out of stock

SKU: GRG2199718 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Double Conversion”,”rank”:3,”value”:”Online Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”5 kVA”,”rank”:4,”value”:”5kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”4.5 kW”,”rank”:6,”value”:”4.5 kW”},{“name”:”Input Voltage”,”normalizedValue”:”208 V AC”,”rank”:7,”value”:”208 V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120 V, 208 V”,”rank”:8,”value”:”120 V, 208 V”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”11 min/3.5 min”,”rank”:9,”value”:”11 min/3.5 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”Not Medical Grade Approved”,”rank”:11,”value”:”Not Medical Grade Approved”},{“name”:”Number of Outlets”,”normalizedValue”:”16″,”rank”:12,”value”:”16″},{“name”:”Height”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”208V AC”,”value”:”208V AC”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Rack”,”value”:”Rack”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”4.5 kW”,”value”:”4.5 kW”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”120V AC, 208V AC”,”value”:”120V AC, 208V AC”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Input Current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”5 kVA”,”value”:”5.0 kVA”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Depth”,”normalizedValue”:”21 in”,”value”:”21 in”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Includes”,”normalizedValue”:”(4) Post Rack Mount Installation Rails, SU5000XFMRT2U Step Down Transformer, USB, DB9 and EPO Cables”,”value”:”(4) Post Rack Mount Installation Rails, SU5000XFMRT2U Step Down Transformer, USB, DB9 and EPO Cables”},{“name”:”Width”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L6-30P”,”value”:”L6-30P”},{“name”:”Watts”,”normalizedValue”:”4,500″,”value”:”4.5kW”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L6-30R, L6-20R, 5-15/20R”,”value”:”5-15/20R, L6-20R, L6-30R”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”value”:”UPS/Surge”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class B (USA), IEC 61000, RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class B (USA), IEC 61000, RoHS, UL1778″},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Green Certification or Other Recognition”,”normalizedValue”:”RoHS”,”value”:”RoHS”},{“name”:”Overall Width”,”normalizedValue”:”17.52 in”,”value”:”17.52 in”},{“name”:”Overall Height”,”normalizedValue”:”6.85 in”,”value”:”6.85 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”5000 VA”,”value”:”5000 VA”},{“name”:”Input Connection”,”normalizedValue”:”NEMA L6-30P Plug”,”value”:”NEMA L6-30P Plug”},{“name”:”Battery Type”,”normalizedValue”:”Lead Acid”,”value”:”Valve Regulated Lead Acid (VRLA)”},{“name”:”Housing Material”,”normalizedValue”:”Sheet Metal”,”value”:”Sheet Metal”},{“name”:”Product Name”,”normalizedValue”:”SmartOnline E SU5000RT4UTF 5kVA Tower/Rack-Mountable UPS”,”value”:”SmartOnline E SU5000RT4UTF 5kVA Tower/Rack-Mountable UPS”},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”10.05 x 17.5 x 20.75″,”value”:”10.050 x 17.500 x 20.750″},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”0 to 6560 ft. / 0 to 2000 m”,”value”:”0 to 6560 ft. / 0 to 2000 m”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”5,000″,”value”:”5000″},{“name”:”Nominal Voltage Details”,”normalizedValue”:”208V default power module setting; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer supports 120V output”,”value”:”208V default power module setting; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer supports 120V output”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”11 min”,”value”:”11 Minute”},{“name”:”Plug/Connector Type”,”normalizedValue”:”NEMA L6-30P”,”value”:”NEMA L6-30P”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”6.85 x 17.5 x 20.67″,”value”:”6.85 x 17.5 x 20.67″},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Package Includes”,”normalizedValue”:”SU5000RT4UHV UPS Power Module;SU5000XFMRT2U Stepdown Transformer;4 Post Rackmount Installation Rails;USB, DB9 and EPO cables”,”value”:”SU5000RT4UHV UPS Power Module;SU5000XFMRT2U Stepdown Transformer;4 Post Rackmount Installation Rails;USB, DB9 and EPO cables”},{“name”:”UPS Certification Details”,”normalizedValue”:”IEC 61000-4-5 1995 B Surge Immunity”,”value”:”IEC 61000-4-5 1995 B Surge Immunity”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V, 208 V”,”value”:”120V; 208V”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”3.50 Minute/11 Minute”,”value”:”3.50 Minute/11 Minute”},{“name”:”Rack Height”,”normalizedValue”:”6 U”,”value”:”6U”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”445″,”value”:”445″},{“name”:”Frequency Compatibility”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less)”,”value”:”2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less)”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC5-192 (qty 1)”,”value”:”RBC5-192 (qty 1)”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Certifications”,”normalizedValue”:”IEC 61000; CSA (Canada); UL 1778″,”value”:”IEC 61000; CSA (Canada); UL 1778″},{“name”:”Product Type”,”normalizedValue”:”Double Conversion Online UPS”,”value”:”Double Conversion Online UPS”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”3 min 30 sec”,”value”:”3.5 min. (4500W)”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH”,”value”:”BP192V12-3U ; BP192V5RT2U (limit 1); BP192V787C-1PH”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions”},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”11 min”,”value”:”11 min. (2250W)”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline E SU5000RT4UTF 5kVA Tower/Rack-Mountable UPS, PowerAlert Software CD-ROM, USB Cable, Serial Cable, EPO Cable, 2 x Sets of Adjustable 4 Post Rack Rails”,”value”:”SmartOnline E SU5000RT4UTF 5kVA Tower/Rack-Mountable UPS, PowerAlert Software CD-ROM, USB Cable, Serial Cable, EPO Cable, 2 x Sets of Adjustable 4 Post Rack Rails”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”208 V AC”,”value”:”208V AC”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”280V (full load) / 300V (90% load or less)”,”value”:”280V (full load) / 300V (90% load or less)”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Storage Temperature Range”,”normalizedValue”:”5 to 122 F / -15 to 50 C”,”value”:”5 to 122 F / -15 to 50 C”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”30A”,”value”:”30A”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime with optional external battery packs”,”value”:”Supports extended runtime with optional external battery packs”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”192″,”value”:”192″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”24A (208V)”,”value”:”24A (208V)”},{“name”:”Output Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Stepdown Transformer Dimensions (hwd / in.)”,”normalizedValue”:”3.5 x 17.5 x 20.75″,”value”:”3.5 x 17.5 x 20.75″},{“name”:”Audible Noise”,”normalizedValue”:”65 dB at 1m front side”,”value”:”65 dB at 1m front side”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”0-2000 m”,”value”:”0-2000 m”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Output Receptacles”,”normalizedValue”:”5-15/20R, L6-30R, L6-20R”,”value”:”(12) 5-15/20R; (2) L6-20R; (2) L6-30R”},{“name”:”Product Line”,”normalizedValue”:”SmartOnline”,”value”:”SmartOnline”},{“name”:”Receptacle Detail”,”normalizedValue”:”12 x NEMA 5-15/20R, 2 x NEMA L6-20R, 2 x NEMA L6-30R”,”value”:”12 x NEMA 5-15/20R, 2 x NEMA L6-20R, 2 x NEMA L6-30R”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,767″,”value”:”1767″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 156V (full load) / 100V (50% load or less)”,”value”:”2% output voltage regulation during undervoltages to 156V (full load) / 100V (50% load or less)”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”5,000″,”value”:”5000″},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”1,708″,”value”:”1708″},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”3 min 30 sec”,”value”:”3.5 minutes (4500w)”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Audible Alarm”,”normalizedValue”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”,”value”:”Unique audible alarms for all major UPS, environmental and power conditions (see manual)”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”2 sets of adjustable 4 post rack rails included”,”value”:”2 sets of adjustable 4 post rack rails included”},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”28.67″,”value”:”28.67″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output frequency regulation +/- 0.05Hz (free running)”,”value”:”Output frequency regulation +/- 0.05Hz (free running)”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”,”value”:”2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)”},{“name”:”Output Circuit Breakers”,”normalizedValue”:”High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 3 5-15/20R outlets each”,”value”:”High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 3 5-15/20R outlets each”},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Load Capacity”,”normalizedValue”:”5000 VA”,”value”:”5000 VA”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Maximum Device Depth (in.)”,”normalizedValue”:”20.75″,”value”:”20.75″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”4,500″,”value”:”4500″},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”174″,”value”:”174″},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)”,”value”:”Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Two contact closure monitoring options available – RELAYIOCARD with six configurable contact closure outputs (uses UPS card slot) and RELAYIOMINI with 3 configurable contact closure outputs (requires removal of USB port module)”,”value”:”Two contact closure monitoring options available – RELAYIOCARD with six configurable contact closure outputs (uses UPS card slot) and RELAYIOMINI with 3 configurable contact closure outputs (requires removal of USB port module)”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”L6-30P”,”value”:”L6-30P”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”11 minutes (2250w)”,”value”:”11 minutes (2250w)”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”640″,”value”:”640″},{“name”:”Relative Humidity”,”normalizedValue”:”5% to 90% (non-condensing)”,”value”:”5% to 90% (non-condensing)”},{“name”:”UPS Housing Material”,”normalizedValue”:”Sheet metal”,”value”:”Sheet metal”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure sine wave”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”25.67″,”value”:”25.67″},{“name”:”Communications Cable”,”normalizedValue”:”USB, DB9 serial and EPO cables included”,”value”:”USB, DB9 serial and EPO cables included”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries”,”value”:”Automatic inverter bypass; Battery Independent Restart; Hot swappable batteries”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”525″,”value”:”525″},{“name”:”Product Series”,”normalizedValue”:”E”,”value”:”E”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,708″,”value”:”1708″},{“name”:”Input Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”6 hours from 10% to 90% (typical, full load discharge)”,”value”:”6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”LED Indicators”,”normalizedValue”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”,”value”:”6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 Hour”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”156V (full load) / 100V (50% load or less, derates linearly)”,”value”:”156V (full load) / 100V (50% load or less, derates linearly)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Alarm cancel switch”,”value”:”Alarm cancel switch”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”1,767″,”value”:”1767″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”2,595″,”value”:”2595″},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”4.5″,”value”:”4.5″},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared”,”value”:”Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”4,500″,”value”:”4500″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Run Time – Half Load”,”normalizedValue”:”11 min”,”value”:”11 min”},{“name”:”Input Current – Maximum”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Plug Configuration”,”normalizedValue”:”L6-30P”,”value”:”L6-30P”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Power Rating – Apparent”,”normalizedValue”:”5 kVA”,”value”:”5 kVA”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, SNMP, USB”,”value”:”DB9 Serial, EPO, SNMP, USB”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”16″,”value”:”16″},{“name”:”Battery Recharge Time”,”normalizedValue”:”6 hr”,”value”:”6 hr”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”2,595 J”,”value”:”2,595 J”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP192V12-3U, BP192V5RT2U, BP192V787C-1PH”,”value”:”BP192V12-3U, BP192V5RT2U, BP192V787C-1PH”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L6-30R, L6-20R”,”value”:”5-20R, L6-20R, L6-30R”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Number of Outlets – UPS”,”normalizedValue”:”16″,”value”:”16″},{“name”:”Transfer Time – Maximum”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Run Time – Full Load”,”normalizedValue”:”3 min 30 sec”,”value”:”3.5 min”},{“name”:”Power Rating – Real”,”normalizedValue”:”4.5 kW”,”value”:”4.5 kW”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Overall Depth”,”normalizedValue”:”20.67 in”,”value”:”20.67 in”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”RBC5-192″,”value”:”RBC5-192″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 5kVA, Online Double Conversion, Out: 120 V, 208 V In: 208 V AC”