UPS System, 550VA, Standby, Out: 110/115/120V AC In: 120V AC

$119,99

UPS System, Standby, Power Rating 550 VA, Wattage 300 W, Input Voltage 120V AC, Output Voltage 115V AC, 120V AC, Backup Time (Half/Full Load) 10 min/3.5 min, Mounting Desktop/Tower, Outlet Type (5) Surge, (5) UPS/Surge, Number of Outlets 10, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation No, Fax/Modem Line Protection Yes, Transfer Time 3 msec from Battery to AC, 4 msec from AC to Battery, Width 11 in

9999 in stock

SKU: GRG2081161 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”550 VA”,”rank”:2,”value”:”550.0 VA”},{“name”:”UPS Type”,”normalizedValue”:”Standby”,”rank”:3,”value”:”Standby”},{“name”:”Power Rating”,”normalizedValue”:”550 VA”,”rank”:4,”value”:”550VA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Desktop”,”rank”:5,”value”:”Desktop/Tower”},{“name”:”Wattage”,”normalizedValue”:”300 W”,”rank”:6,”value”:”300 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V AC”,”rank”:8,”value”:”110/115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”5 min/1.2 min”,”rank”:9,”value”:”5 min/1.2 min”},{“name”:”Outlet Type”,”normalizedValue”:”(4) Surge; (4) UPS/Surge”,”rank”:10,”value”:”(4) Surge; (4) UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”10″,”rank”:12,”value”:”10″},{“name”:”Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Width”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”Footnotes”,”normalizedValue”:”4,6″,”value”:”4,6″},{“name”:”Display Type”,”normalizedValue”:”No Display”,”value”:”No Display”},{“name”:”Ports”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”Input Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Includes”,”normalizedValue”:”USB Cables”,”value”:”USB Cables”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Standards”,”normalizedValue”:”CSA, FCC Part 15 Class B, NOM, RoHS, UL1778″,”value”:”CSA, FCC Part 15 Class B, NOM, RoHS, UL1778″},{“name”:”Transfer Time”,”normalizedValue”:”3 msec from Battery to AC, 4 msec from AC to Battery”,”value”:”3 msec from Battery to AC, 4 msec from AC to Battery”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Depth”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(8) 5-15R”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Height”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Special Features”,”normalizedValue”:”(3) Built-In ECO Outlets w/Auto Off, Poweralert Software”,”value”:”(3) Built-In ECO Outlets w/Auto Off, Poweralert Software”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Overall Height”,”normalizedValue”:”4.13 in”,”value”:”4.13 in”},{“name”:”Overall Width”,”normalizedValue”:”4.33 in”,”value”:”4.33 in”},{“name”:”Housing Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Operating Temp. Range”,”normalizedValue”:”122\u0026deg;F (50\u0026deg;C)”,”value”:”122\u0026deg;F (50\u0026deg;C)”},{“name”:”Capacity – Batteries”,”normalizedValue”:”550 VA/300 W”,”value”:”550 VA/300 W”},{“name”:”Input Connection”,”normalizedValue”:”6 ft Cord with NEMA 5-15P Plug”,”value”:”6 ft Cord with NEMA 5-15P Plug”},{“name”:”Housing Material”,”normalizedValue”:”ABS”,”value”:”ABS”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”420″,”value”:”420″},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.1 x 10.8 x 5.7″,”value”:”3.1 x 10.8 x 5.7″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”10 min”,”value”:”10 min. (150w)”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and overload status”,”value”:”Audible alarm indicates power-failure and overload status”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”139″,”value”:”139″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”300″,”value”:”300″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Switches”,”normalizedValue”:”Combination switch controls on/off power status and self-test operation; second recessed push-button switch enables ECO outlet switching”,”value”:”Combination switch controls on/off power status and self-test operation; second recessed push-button switch enables ECO outlet switching”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); ENERGY STAR Qualified”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); ENERGY STAR Qualified”},{“name”:”LED Indicators”,”normalizedValue”:”3 LEDs indicate power status, overload/check battery and ECO-mode status”,”value”:”3 LEDs indicate power status, overload/check battery and ECO-mode status”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Communications Cable”,”normalizedValue”:”RJ to USB interface cable included”,”value”:”RJ to USB interface cable included”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower; Ultra-compact desktop; Wallmount”,”value”:”Tower; Ultra-compact desktop; Wallmount”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Primary Form Factor”,”normalizedValue”:”Desktop”,”value”:”Desktop”},{“name”:”Hot-Swap PDU options”,”normalizedValue”:”PDUB15 (2U / 8 5-15R outlets)”,”value”:”PDUB15 (2U / 8 5-15R outlets)”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”550″,”value”:”550″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”99″,”value”:”99″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”79″,”value”:”79″},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”10 A”,”value”:”10A”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”IMPORTANT BATTERY REPLACEMENT INFORMATION \u003e If your ECO550UPS has no battery access door, please contact a local electronics repair technician to source and install a matching replacement battery; If your ECO550UPS does have a battery replacement door and the original battery inside has a rating of 12V 3.6AH, please contact Tripp Lite for assistance”,”value”:”IMPORTANT BATTERY REPLACEMENT INFORMATION \u003e If your ECO550UPS has no battery access door, please contact a local electronics repair technician to source and install a matching replacement battery; If your ECO550UPS does have a battery replacement door and the original battery inside has a rating of 12V 3.6AH, please contact Tripp Lite for assistance”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out)”,”value”:”1 line TEL/DSL (1 in / 1 out)”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert software available via free download”,”value”:”PowerAlert software available via free download”},{“name”:”Thermal Dissipation”,”normalizedValue”:”1.17 W”,”value”:”1.17 W”},{“name”:”Load Capacity”,”normalizedValue”:”550 VA/300 W”,”value”:”550 VA/300 W”},{“name”:”Product Series”,”normalizedValue”:”ECO”,”value”:”ECO”},{“name”:”Assembly Required”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Dataline Protection”,”normalizedValue”:”RJ-11″,”value”:”RJ-11″},{“name”:”Additional Information”,”normalizedValue”:”Keyhole mounting slots enable wall-mount installation, Compatible with Tripp Lite’s Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment – ideal for unattended kiosk applications, Switches to battery power as line voltage decreases to 99 volts or less. Resets back to line power mode as line voltage increases to 104V or higher, Switches to battery power as line voltage increases to 139V or higher. Resets back to line power mode when line voltage decerases to 135V or lower, Basic desktop PCs for home/home-office use, network terminals, audio/video and home entertainment systems and other sensitive electronic devices, 550VA / 300 watt UPS provides battery-derived AC output during brownouts and power failures to support entry-level desktop computer with 15 inch LCD monitor up to 17 minutes”,”value”:”Keyhole mounting slots enable wall-mount installation, Compatible with Tripp Lite’s Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment – ideal for unattended kiosk applications, Switches to battery power as line voltage decreases to 99 volts or less. Resets back to line power mode as line voltage increases to 104V or higher, Switches to battery power as line voltage increases to 139V or higher. Resets back to line power mode when line voltage decerases to 135V or lower, Basic desktop PCs for home/home-office use, network terminals, audio/video and home entertainment systems and other sensitive electronic devices, 550VA / 300 watt UPS provides battery-derived AC output during brownouts and power failures to support entry-level desktop computer with 15 inch LCD monitor up to 17 minutes”},{“name”:”Protection Type”,”normalizedValue”:”Brownout, EMI, RFI, Power Failure”,”value”:”Power Failure, EMI / RFI, Brownout”},{“name”:”Status Indicators”,”normalizedValue”:”2 LED Indicator: Line power, Battery power statusMain Power Switch Controls : ON, OFF, SELF-TEST, ALARM CANCEL, Second switch enables \”ECO\” outlet switching”,”value”:”2 LED Indicator: Line power, Battery power statusMain Power Switch Controls : ON, OFF, SELF-TEST, ALARM CANCEL, Second switch enables \”ECO\” outlet switching”},{“name”:”Form Factor”,”normalizedValue”:”Desktop, Wall Mountable”,”value”:”Wall Mountable, Desktop”},{“name”:”Surge Energy Rating”,”normalizedValue”:”420 J”,”value”:”420 J”},{“name”:”Sound Emission”,”normalizedValue”:”40 dB”,”value”:”40 dB”},{“name”:”Battery Life”,”normalizedValue”:”6 yr”,”value”:”6 Year”},{“name”:”Package Contents”,”normalizedValue”:”550VA Standby UPS, ECO550UPS UPS System, USB Cable, Instruction manual with warranty information”,”value”:”550VA Standby UPS, ECO550UPS UPS System, USB Cable, Instruction manual with warranty information”},{“name”:”Waveform Type”,”normalizedValue”:”Sine Wave”,”value”:”Sine Wave”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122°F”,”value”:”122°F (50°C)”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”15 hr”,”value”:”15 Hour”},{“name”:”Alarm”,”normalizedValue”:”On Battery, Low Battery, Overload”,”value”:”On Battery, Low Battery, Overload”},{“name”:”Package Includes”,”normalizedValue”:”ECO550UPS 550VA 300W 120V Standby ECO UPS with 10 Outlets;USB cable;Owner’s manual”,”value”:”ECO550UPS 550VA 300W 120V Standby ECO UPS with 10 Outlets;USB cable;Owner’s manual”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”550″,”value”:”550″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”6.5 hours (10% to 90%)”,”value”:”6.5 hours (10% to 90%)”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.”,”value”:”Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Input voltage range of 90 to 145″,”value”:”Input voltage range of 90 to 145″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Surge/noise protection”,”value”:”Surge/noise protection”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”300″,”value”:”300″},{“name”:”Output Capacity Details”,”normalizedValue”:”4.6A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes; (BATTERY MODE) 110% +/- 10% @ 5 seconds”,”value”:”4.6A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes; (BATTERY MODE) 110% +/- 10% @ 5 seconds”},{“name”:”Product Compliance”,”normalizedValue”:”ENERGY STAR Qualified; FCC Part 15 Class B (USA)”,”value”:”ENERGY STAR Qualified; FCC Part 15 Class B (USA)”},{“name”:”UPS Applications”,”normalizedValue”:”Computer/Peripherals; Retail/Point of Sale; Hospitality”,”value”:”Computer/Peripherals; Retail/Point of Sale; Hospitality”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Product Certifications”,”normalizedValue”:”RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778″,”value”:”RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Load Management Receptacles”,”normalizedValue”:”The ECO Energy-Saving option will automatically POWER OFF three designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 21 watts or more (see manual)”,”value”:”The ECO Energy-Saving option will automatically POWER OFF three designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 21 watts or more (see manual)”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”120V”,”value”:”120V (+6%/-12%)”},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”6561 ft. (2000 m) above sea level”,”value”:”6561 ft. (2000 m) above sea level”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Replaceable internal batteries (see manual)”,”value”:”Replaceable internal batteries (see manual)”},{“name”:”Input Current – Maximum”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”3 yr (Limited)”,”value”:”3 yr Limited”},{“name”:”Power Cord Length”,”normalizedValue”:”5 ft”,”value”:”5 ft”},{“name”:”Visible Indicator Light Conditions”,”normalizedValue”:”Fault”,”value”:”Fault”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Power Rating – Real”,”normalizedValue”:”300 W”,”value”:”300 W”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”316 J”,”value”:”316 J”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Replace Battery”,”value”:”Low Battery, Overload, Replace Battery”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Output Ports Included”,”normalizedValue”:”USB”,”value”:”USB”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”No Automatic Voltage Regulation”,”value”:”No Automatic Voltage Regulation”},{“name”:”Overall Depth”,”normalizedValue”:”7.2 in”,”value”:”7.2 in”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Battery Recharge Time”,”normalizedValue”:”6 hr 30 min”,”value”:”6.5 hr”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Viet Nam”,”value”:”Viet Nam”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 550VA, Standby, Out: 110/115/120V AC In: 120V AC”