UPS System, 3kVA, Online/Double Conversion, Out: 100/110/115/120/127V AC In: 100/115/120/127V AC

$2490,99

UPS System, Online Double Conversion, Power Rating 3 kVA, Wattage 2.7 kW, Input Voltage 100V AC, 110V AC, 115V AC, 120V AC, 127V AC, Output Voltage 100V AC, 110V AC, 115V AC, 120V AC, 127V AC, Backup Time (Half/Full Load) 13.2 min/4.1 min, Mounting Tower, Outlet Type UPS/Surge, Number of Outlets 9, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15/20R, L5-30R, NEMA Plug Configuration L5-30P, Automatic Volts Regulation Yes, Fax/Modem Line Protection Yes

Out of stock

SKU: GRG9415244 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”3 kVA”,”rank”:4,”value”:”3kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”2.7 kW”,”rank”:6,”value”:”2.7 kW”},{“name”:”Input Voltage”,”normalizedValue”:”100/115/120/127V AC”,”rank”:7,”value”:”100/115/120/127V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/115/120/127V AC”,”rank”:8,”value”:”100/110/115/120/127V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”16.7 min/5.7 min”,”rank”:9,”value”:”16.7 min/5.7 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”9″,”rank”:12,”value”:”9″},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”3 kVA”,”value”:”3.0 kVA”},{“name”:”Height”,”normalizedValue”:”10 in”,”value”:”10 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L5-30R, 5-15/20R”,”value”:”(8) 5-15/20R; (1) L5-30R”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), cUL, FCC (USA), REACH, RoHS, UL”,”value”:”CE (Europe), cUL, FCC (USA), REACH, RoHS, UL”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Width”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Input Current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Includes”,”normalizedValue”:”DB9 Cable, USB Cables”,”value”:”DB9 Cable, USB Cables”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”Depth”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Overall Height”,”normalizedValue”:”13.63 in”,”value”:”13.63 in”},{“name”:”Overall Width”,”normalizedValue”:”8.43 in”,”value”:”8.43 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”3000 VA/2700 W”,”value”:”3000 VA/2700 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA L5-30P Plug”,”value”:”NEMA L5-30P Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”100 V AC, 110 V AC, 120 V AC, 127 V AC”,”value”:”100V AC; 110V AC; 120V AC; 127V AC”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 3%”,”value”:”+/- 3%”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”72″,”value”:”72″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”40A”,”value”:”40A”},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)”,”value”:”2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”120V factory default”,”value”:”120V factory default”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”24 A”,”value”:”24A”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”10.2 x 9 x 19.5″,”value”:”10.2 x 9 x 19.5″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 3 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 3 hours from 10% to 90% (typical, full load discharge)”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”55V (33% load), 70V (70% load), 100V (100% load)”,”value”:”55V (33% load), 70V (70% load), 100V (100% load)”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”2,700″,”value”:”2700″},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,626″,”value”:”1626″},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”30A 120V”,”value”:”30A 120V”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min 12 sec”,”value”:”13.2 min. (1350w)”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”External battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”,”value”:”External battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.92″,”value”:”0.92″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Output Capacity Details”,”normalizedValue”:”ON LINE MODE: Maximum output capacity rating is reduced to 2430W (115V), 2295W (110V), 2160W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1890 watts, 115V 1701 watts, 110V 1607 watts, 100V 1512 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”,”value”:”ON LINE MODE: Maximum output capacity rating is reduced to 2430W (115V), 2295W (110V), 2160W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1890 watts, 115V 1701 watts, 110V 1607 watts, 100V 1512 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”100 V, 110 V, 120 V, 127 V”,”value”:”100V; 110V; 120V; 127V”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”2.7″,”value”:”2.7″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 150″,”value”:”2% output voltage regulation during overvoltages to 150″},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.98″,”value”:”0.98″},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”495″,”value”:”495″},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”801″,”value”:”801″},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”188″,”value”:”188″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”259″,”value”:”259″},{“name”:”Operating Elevation (m)”,”normalizedValue”:”Up to 3000m”,”value”:”Up to 3000m”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable four-outlet load banks”,”value”:”Two switchable four-outlet load banks”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”,”value”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC96-3U”,”value”:”RBC96-3U”},{“name”:”Audible Noise”,”normalizedValue”:”\u003c 51.5 dB at front side 1m”,”value”:”\u003c 51.5 dB at front side 1m”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 6 sec”,”value”:”4.1 min. (2700w)”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18 -2US (multi-pack compatible)”,”value”:”BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18 -2US (multi-pack compatible)”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”3″,”value”:”3″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Hot swappable batteries”,”value”:”Automatic inverter bypass; Hot swappable batteries”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU3000XLCD 3000VA Tower UPS, Poweralert Software CD, Owner’s Manual with Warranty Information, EPO (Emergency Power Off) Cable, USB Cable, DB9 Cable”,”value”:”SmartOnline SU3000XLCD 3000VA Tower UPS, Poweralert Software CD, Owner’s Manual with Warranty Information, EPO (Emergency Power Off) Cable, USB Cable, DB9 Cable”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”3 hr”,”value”:”3 Hour”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Load Capacity”,”normalizedValue”:”3000 VA/2700 W”,”value”:”3000 VA/2700 W”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”13.63 x 8.43 x 16.23″,”value”:”13.630 x 8.430 x 16.230″},{“name”:”Power Factor (Input)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”2,700″,”value”:”2700″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Input Cord Length (ft.)”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Package Includes”,”normalizedValue”:”3000VA 2700W 120V Double-Conversion UPS;USB cable;DB9 cable;Quick Start Guide”,”value”:”3000VA 2700W 120V Double-Conversion UPS;USB cable;DB9 cable;Quick Start Guide”},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”911″,”value”:”911″},{“name”:”Product Compliance”,”normalizedValue”:”CE (Europe); FCC (USA)”,”value”:”CE (Europe); FCC (USA)”},{“name”:”AC Suppression Joule Rating”,”normalizedValue”:”190″,”value”:”190″},{“name”:”Product Certifications”,”normalizedValue”:”UL Listed; cUL Listed”,”value”:”UL Listed; cUL Listed”},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”LED Indicators”,”normalizedValue”:”4 status-indicating LEDs”,”value”:”4 status-indicating LEDs”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”744-A4313″,”value”:”744-A4313″},{“name”:”Surge Suppression Rating”,”normalizedValue”:”190 J”,”value”:”190 J”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”,”value”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”9″,”value”:”9″},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Battery Recharge Time”,”normalizedValue”:”3 hr”,”value”:”3 hr”},{“name”:”Input Current – Maximum”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Overall Depth”,”normalizedValue”:”16.2 in”,”value”:”16.2 in”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L5-30R”,”value”:”5-20R, L5-30R”},{“name”:”Power Rating – Real”,”normalizedValue”:”2.7 kW”,”value”:”2.7 kW”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP96V”,”value”:”BP96V”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 3kVA, Online/Double Conversion, Out: 100/110/115/120/127V AC In: 100/115/120/127V AC”