UPS System, 3kVA, Line Interactive, Out: 220/230/240V AC In: 230V AC

$1567,99

UPS System, Line Interactive, Power Rating 3 kVA, Wattage 2.25 kW, Input Voltage 230V AC, Output Voltage 220V AC, 230V AC, 240V AC, Backup Time (Half/Full Load) 14 min/4 min, Mounting Tower, Outlet Type UPS/Surge, Number of Outlets 9, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration C13, C19, NEMA Plug Configuration C20, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 2 to 4 msec, Width 9 in, Depth 12 in, Height 1 in, Cord Length No Cord

Out of stock

SKU: GRG9415077 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”3 kVA”,”rank”:2,”value”:”3.0 kVA”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”3 kVA”,”rank”:4,”value”:”3kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”2.25 kW”,”rank”:6,”value”:”2.25 kW”},{“name”:”Input Voltage”,”normalizedValue”:”230V AC”,”rank”:7,”value”:”230V AC”},{“name”:”Output Voltage”,”normalizedValue”:”220/230/240V AC”,”rank”:8,”value”:”220/230/240V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”14 min/4 min”,”rank”:9,”value”:”14 min/4 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”9″,”rank”:12,”value”:”9″},{“name”:”Standards”,”normalizedValue”:”CE (Europe), RoHS, UL1778CE 62040″,”value”:”CE (Europe), RoHS, UL1778CE 62040″},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Special Features”,”normalizedValue”:”Extended Run”,”value”:”Extended Run”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Height”,”normalizedValue”:”1 in”,”value”:”1 in”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Current”,”normalizedValue”:”15.4 A”,”value”:”15.4 A”},{“name”:”Includes”,”normalizedValue”:”(3) C13 to C14 Power Cables, Cable for Emergency Power Off Interface, PowerAlert Software with USB and DB9 Cables”,”value”:”(3) C13 to C14 Power Cables, Cable for Emergency Power Off Interface, PowerAlert Software with USB and DB9 Cables”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Depth”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”C20″,”value”:”C20″},{“name”:”Width”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”C13, C19″,”value”:”(8) C13; (1) C19″},{“name”:”Cord Length”,”normalizedValue”:”No Cord”,”value”:”No Cord”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Overall Height”,”normalizedValue”:”14.2 in”,”value”:”14.2 in”},{“name”:”Overall Width”,”normalizedValue”:”9.2 in”,”value”:”9.2 in”},{“name”:”Housing Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Operating Temp. Range”,”normalizedValue”:”122\u0026deg;F (50\u0026deg;C)”,”value”:”122\u0026deg;F (50\u0026deg;C)”},{“name”:”Capacity – Batteries”,”normalizedValue”:”3000 VA/2250 W”,”value”:”3000 VA/2250 W”},{“name”:”Housing Material”,”normalizedValue”:”Polycarbonate”,”value”:”Polycarbonate”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”151″,”value”:”151″},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”2,250″,”value”:”2250″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-0.11″,”value”:”-0.11″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 151 and 176 are boosted by 30%”,”value”:”Input voltages between 151 and 176 are boosted by 30%”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”230 V AC”,”value”:”230V AC”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V”,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC54″,”value”:”RBC54″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Three switchable two-outlet C13 load banks”,”value”:”Three switchable two-outlet C13 load banks”},{“name”:”UPS Certification Details”,”normalizedValue”:”CE 62040″,”value”:”CE 62040″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”480″,”value”:”480″},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”14 min”,”value”:”14 min. (1125w)”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Communications Interface”,”normalizedValue”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”2.25″,”value”:”2.25″},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”361″,”value”:”361″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”10A (x2) – each breaker protects 4 C13 outlets each, C19 is unbreakered”,”value”:”10A (x2) – each breaker protects 4 C13 outlets each, C19 is unbreakered”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min”,”value”:”4 min. (2250w)”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Audible Noise”,”normalizedValue”:”Audible Noise \u003c 47dBA At Front Side 1 Meter”,”value”:”Audible Noise \u003c 47dBA At Front Side 1 Meter”},{“name”:”Output Capacity Details”,”normalizedValue”:”Output is reduced to 1500W maximum with 2 or more external battery packs”,”value”:”Output is reduced to 1500W maximum with 2 or more external battery packs”},{“name”:”UPS Input Connection Description”,”normalizedValue”:”User supplies input cabling with C19 output connection”,”value”:”User supplies input cabling with C19 output connection”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”14.2 x 9.2 x 12″,”value”:”14.2 x 9.2 x 12″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 245 and 282 are reduced by 12%”,”value”:”Input voltages between 245 and 282 are reduced by 12%”},{“name”:”Power Factor”,”normalizedValue”:”0.75″,”value”:”0.75″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 177 and 199 are boosted by 14%”,”value”:”Input voltages between 177 and 199 are boosted by 14%”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”282″,”value”:”282″},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD”,”value”:”SNMPWEBCARD; TLNETCARD; WEBCARDLX”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”220 V, 230 V, 240 V”,”value”:”220V; 230V; 240V”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”305″,”value”:”305″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Communications Cable”,”normalizedValue”:”2 USB and 2 DB9 cables included”,”value”:”2 USB and 2 DB9 cables included”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Automatic frequency selection”,”value”:”Automatic frequency selection”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”15.4 A”,”value”:”15.4A”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”},{“name”:”UPS Certifications”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Included Output Power Cables”,”normalizedValue”:”Includes 3 C13 to C14 output power cables”,”value”:”Includes 3 C13 to C14 output power cables”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”,”value”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro 3000VA Line Interactive Tower UPS, SMARTINT3000VS UPS System, PowerAlert software with USB and DB9 cables, Cable for Emergency Power Off interface, Instruction manual with warranty information, C13 to C14 power cables (3)”,”value”:”SmartPro 3000VA Line Interactive Tower UPS, SMARTINT3000VS UPS System, PowerAlert software with USB and DB9 cables, Cable for Emergency Power Off interface, Instruction manual with warranty information, C13 to C14 power cables (3)”},{“name”:”Load Capacity”,”normalizedValue”:”3000 VA/2250 W”,”value”:”3000 VA/2250 W”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122°F”,”value”:”122°F (50°C)”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Battery Life”,”normalizedValue”:”6 yr”,”value”:”6 Year”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Status Indicators”,”normalizedValue”:”5 Front panel LEDs: Line power status, Battery power status, Battery low/replace status, Voltage regulation operation”,”value”:”5 Front panel LEDs: Line power status, Battery power status, Battery low/replace status, Voltage regulation operation”},{“name”:”Waveform Type”,”normalizedValue”:”Sine Wave”,”value”:”Sine Wave”},{“name”:”Additional Information”,”normalizedValue”:”3000VA power handling capability offers compatibility with networking, telecom and other sensitive electronic devices, Runtime is further expandable with the addition of BP48V18 external battery packs, Maintains regulated 230V nominal output during brownouts and overvoltages from 151 to 282V, Includes 9 UPS supported outlets arranged in 3 individually controllable load banks, Network-grade AC surge suppression”,”value”:”3000VA power handling capability offers compatibility with networking, telecom and other sensitive electronic devices, Runtime is further expandable with the addition of BP48V18 external battery packs, Maintains regulated 230V nominal output during brownouts and overvoltages from 151 to 282V, Includes 9 UPS supported outlets arranged in 3 individually controllable load banks, Network-grade AC surge suppression”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Alarm”,”normalizedValue”:”Utility Power Failure”,”value”:”Utility Power Failure”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Surge Energy Rating”,”normalizedValue”:”1800 J”,”value”:”1800 J”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”480 J”,”value”:”480 J”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 hr”},{“name”:”Input Current – Maximum”,”normalizedValue”:”15.4 A”,”value”:”15.4 A”},{“name”:”Power Cord Length”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Overall Depth”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Receptacle Configuration”,”normalizedValue”:”C13, C19″,”value”:”C13, C19″},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”9″,”value”:”9″},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Power Rating – Real”,”normalizedValue”:”2.25 kW”,”value”:”2.25 kW”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 3kVA, Line Interactive, Out: 220/230/240V AC In: 230V AC”