UPS System, 3kVA, Line Interactive, Out: 110/115/120V AC In: 120V AC

$2092,99

UPS System, Line Interactive, Power Rating 3 kVA, Wattage 2.25 kW, Input Voltage 120V AC, Output Voltage 120V AC, Backup Time (Half/Full Load) 10 min/3.5 min, Mounting Rack, Outlet Type UPS/Surge, Number of Outlets 9, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15/20R, L5-30R, NEMA Plug Configuration L5-30P, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 1 to 5 msec, Width 18 in, Depth 20 in, Height 4 in, Cord Length 10 ft

Out of stock

SKU: GRG9415016 Category:

Description

[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”3 kVA”,”rank”:2,”value”:”3.0 kVA”},{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”3 kVA”,”rank”:4,”value”:”3kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”3 kW”,”rank”:6,”value”:”3 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”110/115/120V AC”,”rank”:8,”value”:”110/115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”9 min/3 min”,”rank”:9,”value”:”9 min/3 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”9″,”rank”:12,”value”:”9″},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Special Features”,”normalizedValue”:”Hot Swappable Batteries”,”value”:”Hot Swappable Batteries”},{“name”:”Depth”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L5-30R, 5-15/20R”,”value”:”(8) 5-15/20R; (1) L5-30R”},{“name”:”Width”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), ENERGY STAR Qualified, FCC Part 15 Class a (USA), ICES (Canada), NOM (Mexico), REACH, RoHS, UL1778″,”value”:”CSA (Canada), ENERGY STAR Qualified, FCC Part 15 Class a (USA), ICES (Canada), NOM (Mexico), REACH, RoHS, UL1778″},{“name”:”Input Current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”L5-30P”,”value”:”L5-30P”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Transfer Time”,”normalizedValue”:”1 to 5 msec”,”value”:”1 to 5 msec”},{“name”:”Includes”,”normalizedValue”:”(4) Post Rack Mount Installation Kits, PowerAlert Software with USB, Serial and EPO Cables”,”value”:”(4) Post Rack Mount Installation Kits, PowerAlert Software with USB, Serial and EPO Cables”},{“name”:”Overall Width”,”normalizedValue”:”17.2 in”,”value”:”17.2 in”},{“name”:”Overall Height”,”normalizedValue”:”3.4 in”,”value”:”3.4 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”3000 VA/2250 W”,”value”:”3000 VA/2250 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA L5-30P Plug”,”value”:”NEMA L5-30P Plug”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”LED Indicators”,”normalizedValue”:”Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).”,”value”:”Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). LX Platform Interface Status: Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”2.25″,”value”:”2.25″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Network Speed”,”normalizedValue”:”10/100 Mbps”,”value”:”10/100 Mbps”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”3 min 30 sec”,”value”:”3.5 min. (2250w)”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”24 A”,”value”:”24A”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 108 and 96 are boosted by 12%”,”value”:”Input voltages between 108 and 96 are boosted by 12%”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”10 min”,”value”:”10 min. (1125w)”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Output with external battery pack configurations is limited to 1600 watts maximum”,”value”:”Output with external battery pack configurations is limited to 1600 watts maximum”},{“name”:”EPO Port”,”normalizedValue”:”RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems”,”value”:”RJ11 interface jack with 4-meter cable included. Supports normally open and normally closed EPO systems”},{“name”:”Power Factor”,”normalizedValue”:”0.75″,”value”:”0.75″},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 83 and 95 are boosted by 24%”,”value”:”Input voltages between 83 and 95 are boosted by 24%”},{“name”:”Network Monitoring Port”,”normalizedValue”:”RJ45 Network port, Micro-USB Configuration/Console port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.”,”value”:”RJ45 Network port, Micro-USB Configuration/Console port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.”},{“name”:”Network UPS Tools Compatibility”,”normalizedValue”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”,”value”:”NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite”},{“name”:”Communications Cable”,”normalizedValue”:”Micro-USB, USB, and DB9 cabling included”,”value”:”Micro-USB, USB, and DB9 cabling included”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Communications Interface”,”normalizedValue”:”(1) DB9 Serial; (1) EPO (emergency power off); (1) Micro-USB; (1) Pre-installed network card; (1) RJ45 Network; USB (HID enabled); (1) USB-A; (1) USB-B”,”value”:”(1) DB9 Serial; (1) EPO (emergency power off); (1) Micro-USB; (1) Pre-installed network card; (1) RJ45 Network; USB (HID enabled); (1) USB-A; (1) USB-B”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”4 post 19 inch rackmount”,”value”:”4 post 19 inch rackmount”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4.5 hours from 10% to 90%”,”value”:”Less than 4.5 hours from 10% to 90%”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Includes pre-installed WEBCARDLX Network Management Card interface”,”value”:”Includes pre-installed WEBCARDLX Network Management Card interface”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”,”value”:”Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”3,000″,”value”:”3000″},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”26.46″,”value”:”26.46″},{“name”:”Output Circuit Breakers”,”normalizedValue”:”Two 20A output breakers protect 4 5-15/20R outlets each”,”value”:”Two 20A output breakers protect 4 5-15/20R outlets each”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.43 x 17.32 x 19.46″,”value”:”3.43 x 17.32 x 19.46″},{“name”:”Audible Noise”,”normalizedValue”:”45 dBA maximum, front side 1m”,”value”:”45 dBA maximum, front side 1m”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+6%, -14%”,”value”:”-14%, +6%”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,356″,”value”:”1356″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”189″,”value”:”189″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”,”value”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC94-2U”,”value”:”RBC94-2U”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Grounding Lug”,”normalizedValue”:”Includes back panel grounding lug”,”value”:”Includes back panel grounding lug”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”2,250″,”value”:”2250″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in Serial or USB communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert. LX Platform Interface: PowerAlert Device Manager 15 (PADM15)”,”value”:”For local monitoring via the UPSâ„¢s built-in Serial or USB communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert. LX Platform Interface: PowerAlert Device Manager 15 (PADM15)”},{“name”:”UPS Certification Details”,”normalizedValue”:”SAFETY STANDARD (U.S.) – UL1778:2014 (5th Ed) R10.17; SAFETY STANDARD (CANADA) – CAN/CSA-C22.2 No. 107.3-14 (3rd Ed) + GI1 / FCC/ICES COMPLIANT – CLASS A”,”value”:”SAFETY STANDARD (U.S.) – UL1778:2014 (5th Ed) R10.17; SAFETY STANDARD (CANADA) – CAN/CSA-C22.2 No. 107.3-14 (3rd Ed) + GI1 / FCC/ICES COMPLIANT – CLASS A”},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”24.46″,”value”:”24.46″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.98″,”value”:”0.98″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”30A 120V”,”value”:”30A 120V”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”83″,”value”:”83″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”87″,”value”:”87″},{“name”:”Switches”,”normalizedValue”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset”,”value”:”3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 127 and 145 are reduced by 12%”,”value”:”Input voltages between 127 and 145 are reduced by 12%”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable single-outlet load banks”,”value”:”Two switchable single-outlet load banks”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”494″,”value”:”494″},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”3″,”value”:”3″},{“name”:”UPS Certifications”,”normalizedValue”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”,”value”:”2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”SNMP Compatibility”,”normalizedValue”:”V3, SNMP V1, V2c”,”value”:”SNMP V1, V2c, V3″},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Package Contents”,”normalizedValue”:”SMART3000RM2UN UPS System with Pre-installed WEBCARDLX, PowerAlert Software CD, USB Cable, Serial Cable, EPO Cable, 4 Post Installation Kit, Instruction Manual”,”value”:”SMART3000RM2UN UPS System with Pre-installed WEBCARDLX, PowerAlert Software CD, USB Cable, Serial Cable, EPO Cable, 4 Post Installation Kit, Instruction Manual”},{“name”:”Load Capacity”,”normalizedValue”:”3000 VA/2250 W”,”value”:”3000 VA/2250 W”},{“name”:”Product Series”,”normalizedValue”:”SmartPro”,”value”:”SmartPro”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.50 Hour”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr, 3 yr (Registration)”,”value”:”2 yr, 3 yr Registration”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L5-30R”,”value”:”5-20R, L5-30R”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”380 J”,”value”:”380 J”},{“name”:”Power Rating – Real”,”normalizedValue”:”2.25 kW”,”value”:”2.25 kW”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Input Current – Maximum”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Overall Depth”,”normalizedValue”:”23.7 in”,”value”:”23.7 in”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Battery Recharge Time”,”normalizedValue”:”5 hr”,”value”:”5 hr”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 3kVA, Line Interactive, Out: 110/115/120V AC In: 120V AC”