Description
[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”330 VA”,”rank”:2,”value”:”330.0 VA”},{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”330 VA”,”rank”:4,”value”:”330VA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Wall”,”rank”:5,”value”:”Tower/Wall”},{“name”:”Wattage”,”normalizedValue”:”225 W”,”rank”:6,”value”:”225 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120V AC”,”rank”:8,”value”:”120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”46 min/18 min”,”rank”:9,”value”:”46 min/18 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”Yes”,”rank”:11,”value”:”Yes”},{“name”:”Number of Outlets”,”normalizedValue”:”4″,”rank”:12,”value”:”4″},{“name”:”Width”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Special Features”,”normalizedValue”:”Poweralert Software, Voltage Regulation”,”value”:”Poweralert Software, Voltage Regulation”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Display Type”,”normalizedValue”:”No Display”,”value”:”No Display”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(4) 5-15R”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Current”,”normalizedValue”:”2.3 A”,”value”:”2.3 A”},{“name”:”Height”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”Depth”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Includes”,”normalizedValue”:”Serial Cable for Remote Monitoring, UPS System”,”value”:”Serial Cable for Remote Monitoring, UPS System”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial”,”value”:”DB9 Serial”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Standards”,”normalizedValue”:”CSA, FCC Part 15 Class B, RoHS, UL 60601-1, UL1778″,”value”:”CSA, FCC Part 15 Class B, RoHS, UL 60601-1, UL1778″},{“name”:”Footnotes”,”normalizedValue”:”3,6,14″,”value”:”3,6,14″},{“name”:”Overall Width”,”normalizedValue”:”5.2 in”,”value”:”5.2 in”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Overall Height”,”normalizedValue”:”10.8 in”,”value”:”10.8 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”330 VA/225 W”,”value”:”330 VA/225 W”},{“name”:”Operating Temp. Range”,”normalizedValue”:”104\u0026deg;F (40\u0026deg;C)”,”value”:”104\u0026deg;F (40\u0026deg;C)”},{“name”:”Battery Type”,”normalizedValue”:”Sealed Lead Acid”,”value”:”Sealed Lead Acid (SLA)”},{“name”:”Input Connection”,”normalizedValue”:”6 ft Cord with NEMA 5-15P-HG Plug”,”value”:”6 ft Cord with NEMA 5-15P-HG Plug”},{“name”:”Housing Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”330″,”value”:”330″},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”10.8 x 5.2 x 7.2″,”value”:”10.8 x 5.2 x 7.2″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”183″,”value”:”183″},{“name”:”Output Receptacle Details”,”normalizedValue”:”Hospital grade output receptacles”,”value”:”Hospital grade output receptacles”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”48.8″,”value”:”48.8″},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4.5 hours from 10% to 90%”,”value”:”Less than 4.5 hours from 10% to 90%”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”215.8″,”value”:”215.8″},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC52 (quantity 2)”,”value”:”RBC52 (quantity 2)”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”2 line TEL/DSL”,”value”:”2 line TEL/DSL”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”274″,”value”:”274″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”225″,”value”:”225″},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”Wallmount (UPSWM – tower mounting kit)”,”value”:”Wallmount (UPSWM – tower mounting kit)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Communications Cable”,”normalizedValue”:”DB9 serial cable included”,”value”:”DB9 serial cable included”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery conditions”,”value”:”Audible alarm indicates power-failure and low-battery conditions”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-18%, +8%”,”value”:”-18%, +8%”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”139″,”value”:”139″},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”46 min”,”value”:”46 min. (115w)”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”LED Indicators”,”normalizedValue”:”4 LEDs indicate line power, battery power, overload and battery low/replace status”,”value”:”4 LEDs indicate line power, battery power, overload and battery low/replace status”},{“name”:”Communications Interface”,”normalizedValue”:”DB9 Serial”,”value”:”DB9 Serial”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”18 min”,”value”:”18 min. (225w)”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”3.5A”,”value”:”3.5A”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 89 and 107 are boosted by 14%”,”value”:”Input voltages between 89 and 107 are boosted by 14%”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); Tested to UL60601-1 (medical grade)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); Tested to UL60601-1 (medical grade)”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”2.3 A”,”value”:”2.3A”},{“name”:”Output Isolation Transformer”,”normalizedValue”:”Hospital grade load isolation transformer”,”value”:”Hospital grade load isolation transformer”},{“name”:”Grounding Lug”,”normalizedValue”:”Grounding lug”,”value”:”Grounding lug”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”120 V”,”value”:”120V”},{“name”:”Package Contents”,”normalizedValue”:”OmniSmart 350HG UPS, OMNI SMART 350HG Hospital Grade UPS System, Serial cable for remote monitoring, Warranty information, Instruction manual”,”value”:”OmniSmart 350HG UPS, OMNI SMART 350HG Hospital Grade UPS System, Serial cable for remote monitoring, Warranty information, Instruction manual”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Load Capacity”,”normalizedValue”:”330 VA/225 W”,”value”:”330 VA/225 W”},{“name”:”Additional Information”,”normalizedValue”:”Ideal UPS protection for applications in medical patient-care areas where UL2601-1 listed electrical medical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation prevents shock potential and operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 330VA / 225 watts, 46 minutes half load runtime (with 165VAload), 18 minutes full load runtime (with 330VA load), 4 protected hospital-grade outlets; 6-ft. cord, 1-DB9 serial port for network interface; SNMP compatible, Complete surge protection, line isolation and EMI/RFI noise filtering, 2 phone line surge suppression for modems, fax machines and other phone accessories, 2 year product warranty, Complete remote monitoring cabling included, PowerAlert UPS managment software available via free download, 4 diagnostic LEDs indicate AC present, on battery, voltage correction \u0026 battery low/replace, Battery replacement door, Grounding lug”,”value”:”Ideal UPS protection for applications in medical patient-care areas where UL2601-1 listed electrical medical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation prevents shock potential and operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 330VA / 225 watts, 46 minutes half load runtime (with 165VAload), 18 minutes full load runtime (with 330VA load), 4 protected hospital-grade outlets; 6-ft. cord, 1-DB9 serial port for network interface; SNMP compatible, Complete surge protection, line isolation and EMI/RFI noise filtering, 2 phone line surge suppression for modems, fax machines and other phone accessories, 2 year product warranty, Complete remote monitoring cabling included, PowerAlert UPS managment software available via free download, 4 diagnostic LEDs indicate AC present, on battery, voltage correction \u0026 battery low/replace, Battery replacement door, Grounding lug”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Battery Life”,”normalizedValue”:”6 yr”,”value”:”6 Year”},{“name”:”Status Indicators”,”normalizedValue”:”Includes 4 front-panel status indicator LEDs for line power, battery power, voltage regulation and battery low/replace status”,”value”:”Includes 4 front-panel status indicator LEDs for line power, battery power, voltage regulation and battery low/replace status”},{“name”:”Alarm”,”normalizedValue”:”On Battery”,”value”:”On Battery”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104°F”,”value”:”104°F (40°C)”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class B (USA)”,”value”:”FCC Part 15 Class B (USA)”},{“name”:”Grounding Details”,”normalizedValue”:”Grounding lug”,”value”:”Grounding lug”},{“name”:”Package Includes”,”normalizedValue”:”OMNI SMART 350HG Hospital Grade UPS System;Serial cable for remote monitoring;Warranty information;Instruction manual”,”value”:”OMNI SMART 350HG Hospital Grade UPS System;Serial cable for remote monitoring;Warranty information;Instruction manual”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); UL 1778; UL 60601-1″,”value”:”CSA (Canada); UL 1778; UL 60601-1″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”330″,”value”:”330″},{“name”:”UPS Applications”,”normalizedValue”:”Hospital/Medical”,”value”:”Hospital/Medical”},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Half Load”,”normalizedValue”:”78.3″,”value”:”78.3″},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”225″,”value”:”225″},{“name”:”Visible Indicator Light Conditions”,”normalizedValue”:”Battery Low, Replace Battery”,”value”:”Battery Low, Replace Battery”},{“name”:”Overall Depth”,”normalizedValue”:”7.2 in”,”value”:”7.2 in”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial”,”value”:”DB9 Serial”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery”,”value”:”Low Battery”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Power Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Power Rating – Real”,”normalizedValue”:”225 W”,”value”:”225 W”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”RBC52″,”value”:”RBC52″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.5 hr”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr (Limited)”,”value”:”2 yr Limited”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Input Current – Maximum”,”normalizedValue”:”2.3 A”,”value”:”2.3 A”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.