UPS System, 2.2kVA, Line Interactive, Out: 120 V AC In: 120 V AC

$2276,99

UPS System, Line Interactive, Power Rating 2.2 kVA, Wattage 1.9 kW, Input Voltage 120V AC, Output Voltage 120V AC, Backup Time (Half/Full Load) 28 min/11 min, Mounting Desktop/Tower, Outlet Type UPS/Surge, Number of Outlets 4, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-20P, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 5 msec, Width 17 in, Depth 18 in, Height 7 in, Cord Length 10 ft, Display Type LED

Out of stock

SKU: GRG6096982 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”2.2 kVA”,”rank”:4,”value”:”2.2kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Rack”,”rank”:5,”value”:”Rack, Tower”},{“name”:”Wattage”,”normalizedValue”:”1.9 kW”,”rank”:6,”value”:”1.9 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120 V AC”,”rank”:7,”value”:”120 V AC”},{“name”:”Output Voltage”,”normalizedValue”:”120 V AC”,”rank”:8,”value”:”120 V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”28 min/11 min”,”rank”:9,”value”:”28 min/11 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”Not Medical Grade Approved”,”rank”:11,”value”:”Not Medical Grade Approved”},{“name”:”Number of Outlets”,”normalizedValue”:”4″,”rank”:12,”value”:”4″},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”value”:”UPS/Surge”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Height”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Input Current”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Footnotes”,”normalizedValue”:”Slot for SNMPWEBCARD”,”value”:”Slot for SNMPWEBCARD”},{“name”:”Special Features”,”normalizedValue”:”Cold Start Operation Supported, Hot Swappable Batteries, Individually Controllable Load Banks”,”value”:”Cold Start Operation Supported, Hot Swappable Batteries, Individually Controllable Load Banks”},{“name”:”Transfer Time”,”normalizedValue”:”5 msec”,”value”:”5 msec”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Tower, Desktop”,”value”:”Desktop/Tower”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Depth”,”normalizedValue”:”18 in”,”value”:”18 in”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”2.2 kVA”,”value”:”2.2 kVA”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Width”,”normalizedValue”:”17 in”,”value”:”17 in”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Ports”,”normalizedValue”:”EPO, RS232, Slot for SNMPWEBCARD, USB”,”value”:”EPO, RS232, Slot for SNMPWEBCARD, USB”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Includes”,”normalizedValue”:”(2) Post Rackmount Installation Brackets, USB and Serial Cables”,”value”:”(2) Post Rackmount Installation Brackets, USB and Serial Cables”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”1.9 kW”,”value”:”1.9 kW”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), NOM (Mexico), RoHS, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), NOM (Mexico), RoHS, UL1778″},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”Watts”,”normalizedValue”:”1,900″,”value”:”1.9kW”},{“name”:”Green Certification or Other Recognition”,”normalizedValue”:”Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), Class A (EMI)”,”value”:”Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), Class A (EMI)”},{“name”:”Overall Height”,”normalizedValue”:”6.89 in”,”value”:”6.89 in”},{“name”:”Overall Width”,”normalizedValue”:”17.3 in”,”value”:”17.3 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”2200 VA/1900 W”,”value”:”2200 VA/1900 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-15P Plug”,”value”:”NEMA 5-15P Plug”},{“name”:”Housing Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Battery Type”,”normalizedValue”:”Lead Acid”,”value”:”Valve Regulated Lead Acid (VRLA)”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”28 min”,”value”:”28 min. (950w)”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”120v nominal output in battery mode”,”value”:”120v nominal output in battery mode”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”UPS Applications”,”normalizedValue”:”Large Network”,”value”:”Large Network”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 83 and 95 are boosted by 24%”,”value”:”Input voltages between 83 and 95 are boosted by 24%”},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 127 and 145 are reduced by 12%”,”value”:”Input voltages between 127 and 145 are reduced by 12%”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Load Management Receptacles”,”normalizedValue”:”Three switchable single-outlet 5-15R load banks”,”value”:”Three switchable single-outlet 5-15R load banks”},{“name”:”Package Includes”,”normalizedValue”:”SmartPro Compact 4U Rackmount UPS system;2 post rackmount installation brackets;USB and Serial Cabling;Owner’s manual”,”value”:”SmartPro Compact 4U Rackmount UPS system;2 post rackmount installation brackets;USB and Serial Cabling;Owner’s manual”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”11 Minute/28 Minute”,”value”:”11 Minute/28 Minute”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Runtime Full Load (min.)”,”normalizedValue”:”11 min”,”value”:”11 min. (1900W)”},{“name”:”Load Capacity”,”normalizedValue”:”2200 VA/1900 W”,”value”:”2200 VA/1900 W”},{“name”:”Plug/Connector Type”,”normalizedValue”:”NEMA 5-20P”,”value”:”NEMA 5-20P”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”2.2″,”value”:”2.2″},{“name”:”Product Name”,”normalizedValue”:”SmartPro SMART2200CRMXL 2200VA Rack-mountable UPS”,”value”:”SmartPro SMART2200CRMXL 2200VA Rack-mountable UPS”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”3 hr 36 min”,”value”:”3.60 Hour”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack”,”value”:”Rack/Tower”},{“name”:”Output Receptacles”,”normalizedValue”:”5-15R; 5-15/20R”,”value”:”(4) 5-15R; (4) 5-15/20R”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”452″,”value”:”452″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”2 post 19 inch rackmount”,”value”:”2 post 19 inch rackmount”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”6.89 x 17.3 x 17.8″,”value”:”6.89 x 17.30 x 17.80″},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Audible Noise”,”normalizedValue”:”45 dBA maximum, front side 1m”,”value”:”45 dBA maximum, front side 1m”},{“name”:”Battery Access”,”normalizedValue”:”Front panel battery access door”,”value”:”Front panel battery access door”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”83″,”value”:”83″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”1,900″,”value”:”1900″},{“name”:”Frequency Compatibility”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”439″,”value”:”439″},{“name”:”Minimum Required Rack Depth without External Battery Pack (in.)”,”normalizedValue”:”22.8″,”value”:”22.8″},{“name”:”Product Line”,”normalizedValue”:”SmartPro”,”value”:”SmartPro”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Battery Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”885″,”value”:”885″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”2,200″,”value”:”2200″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”175″,”value”:”175″},{“name”:”Minimum Required Rack Depth with External Battery Pack (in.)”,”normalizedValue”:”24.8″,”value”:”24.8″},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included 2POSTRMKITWM mounting accessory enables 2-post rackmount installation”,”value”:”Included 2POSTRMKITWM mounting accessory enables 2-post rackmount installation”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Product Type”,”normalizedValue”:”Line-interactive UPS”,”value”:”Line-interactive UPS”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”Modem (RJ-11)”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support low/high charger settings”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support low/high charger settings”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Rack Height”,”normalizedValue”:”4 U”,”value”:”4U”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Sine wave”,”value”:”Sine wave”},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”21″,”value”:”21″},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”11 min”,”value”:”11 min. (1900w)”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”28 min”,”value”:”28 Minute”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”2,200″,”value”:”2200″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”20A”,”value”:”20A”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”16A”,”value”:”16A”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-18% +8%”,”value”:”-18%, +8%”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”885″,”value”:”885″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”20A 120V”,”value”:”20A 120V”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”242″,”value”:”242″},{“name”:”Runtime Half Load (min.)”,”normalizedValue”:”28 min”,”value”:”28 min. (950W)”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 3.6 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 3.6 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Certifications \u0026 Standards”,”normalizedValue”:”Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), Class A (EMI)”,”value”:”Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), Class A (EMI)”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”1.9″,”value”:”1.9″},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 96 and 108 are boosted by 12%”,”value”:”Input voltages between 96 and 108 are boosted by 12%”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro SMART2200CRMXL 2200VA Rack-mountable UPS, SmartPro Compact 4U Rackmount UPS system, 2 post rackmount installation brackets, USB and Serial Cabling, Owner’s manual with warranty information”,”value”:”SmartPro SMART2200CRMXL 2200VA Rack-mountable UPS, SmartPro Compact 4U Rackmount UPS system, 2 post rackmount installation brackets, USB and Serial Cabling, Owner’s manual with warranty information”},{“name”:”Receptacle Detail”,”normalizedValue”:”4 x NEMA 5-15/20R, 4 x NEMA 5-15R”,”value”:”4 x NEMA 5-15/20R, 4 x NEMA 5-15R”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC94-2U (quantity 2)”,”value”:”RBC94-2U (quantity 2)”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); NOM (Mexico); UL 1778″,”value”:”CSA (Canada); NOM (Mexico); UL 1778″},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”4 post rackmount full-depth ( 4POSTRAILKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND )”,”value”:”4 post rackmount full-depth ( 4POSTRAILKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND )”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V24-2U (limit 1); BP48V48RT4U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”,”value”:”BP48V24-2U (limit 1); BP48V48RT4U (multi-pack compatible); BP48V27-2US (multi-pack compatible)”},{“name”:”Power Factor”,”normalizedValue”:”0.86″,”value”:”0.86″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,900″,”value”:”1900″},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, RELAYIOCARD”,”value”:”SNMPWEBCARD ; WEBCARDLX ; RELAYIOCARD”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Run Time – Full Load”,”normalizedValue”:”11 min”,”value”:”11 min”},{“name”:”Input Current – Maximum”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Output Ports Included”,”normalizedValue”:”EPO, RS-232, SNMP, USB”,”value”:”EPO, RS-232, SNMP, USB”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Transfer Time – Maximum”,”normalizedValue”:”5 msec”,”value”:”5 msec”},{“name”:”Plug Configuration”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr, 3 yr (Registration)”,”value”:”2 yr, 3 yr Registration”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Power Rating – Apparent”,”normalizedValue”:”2.2 kVA”,”value”:”2.2 kVA”},{“name”:”Battery Recharge Time”,”normalizedValue”:”3 hr 36 min”,”value”:”3.6 hr”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”570 J”,”value”:”570 J”},{“name”:”Power Rating – Real”,”normalizedValue”:”1.9 kW”,”value”:”1.9 kW”},{“name”:”Number of Outlets – UPS”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Run Time – Half Load”,”normalizedValue”:”28 min”,”value”:”28 min”},{“name”:”Overall Depth”,”normalizedValue”:”17.8 in”,”value”:”17.8 in”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 2.2kVA, Line Interactive, Out: 120 V AC In: 120 V AC”