Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”2.2 kVA”,”rank”:4,”value”:”2.2kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”1.92 kW”,”rank”:6,”value”:”1.92 kW”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”115/120V AC”,”rank”:8,”value”:”115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”13 min/4.4 min”,”rank”:9,”value”:”13 min/4.4 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”Yes”,”rank”:11,”value”:”Yes”},{“name”:”Number of Outlets”,”normalizedValue”:”8″,”rank”:12,”value”:”8″},{“name”:”Width”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Special Features”,”normalizedValue”:”Extended Run, Medical Grade”,”value”:”Extended Run, Medical Grade”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), RoHS, UL1778, UL60601-1″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), RoHS, UL1778, UL60601-1″},{“name”:”Includes”,”normalizedValue”:”AC Power Cord (C19 to NEMA 5-20P), PowerAlert Software and Cables”,”value”:”AC Power Cord (C19 to NEMA 5-20P), PowerAlert Software and Cables”},{“name”:”Height”,”normalizedValue”:”10 in”,”value”:”10 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Current”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”2.2 kVA”,”value”:”2.2 kVA”},{“name”:”Depth”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”C13, 5-15/20R”,”value”:”(4) 5-15/20R; (4) C13″},{“name”:”Overall Width”,”normalizedValue”:”8.9 in”,”value”:”8.9 in”},{“name”:”Overall Height”,”normalizedValue”:”9.72 in”,”value”:”9.72 in”},{“name”:”Housing Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”81″,”value”:”81″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min”,”value”:”13 minutes”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible)”,”value”:”BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible)”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”20A 120V”,”value”:”20A 120V”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”315.2″,”value”:”315.2″},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”247″,”value”:”247″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”2,200″,”value”:”2200″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”16 AMP”,”value”:”16 AMP”},{“name”:”Output Receptacle Details”,”normalizedValue”:”Hospital grade output receptacles”,”value”:”Hospital grade output receptacles”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”115 V, 120 V”,”value”:”115V; 120V”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”Wallmount (UPSWM – tower mounting kit)”,”value”:”Wallmount (UPSWM – tower mounting kit)”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 serial cabling included”,”value”:”USB and DB9 serial cabling included”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”9.72 x 8.9 x 19.09″,”value”:”9.72 x 8.90 x 19.09″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”940″,”value”:”940″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-18%, +8%”,”value”:”-18%, +8%”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 96 and 106 are boosted by 10%”,”value”:”Input voltages between 96 and 106 are boosted by 10%”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC48V-HGTWR”,”value”:”RBC48V-HGTWR”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”143″,”value”:”143″},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”Power Factor”,”normalizedValue”:”0.87″,”value”:”0.87″},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 81 and 95 are boosted by 21%”,”value”:”Input voltages between 81 and 95 are boosted by 21%”},{“name”:”Output Isolation Transformer”,”normalizedValue”:”Hospital grade load isolation transformer”,”value”:”Hospital grade load isolation transformer”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.50 Hour”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”485″,”value”:”485″},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Load Capacity”,”normalizedValue”:”2200 VA/1920 W”,”value”:”2200 VA/1920 W”},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 24 sec”,”value”:”4.4 minutes”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”2 x 20A”,”value”:”2 x 20A”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Package Contents”,”normalizedValue”:”SMART 2500XLHG Medical Grade Tower UPS System, Poweralert Software CD, Warranty Information, Instruction Manual, USB Cable, DB9 Cable”,”value”:”SMART 2500XLHG Medical Grade Tower UPS System, Poweralert Software CD, Warranty Information, Instruction Manual, USB Cable, DB9 Cable”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 126 and 143 are reduced by 9%”,”value”:”Input voltages between 126 and 143 are reduced by 9%”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,920″,”value”:”1920″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”115V (+/- 5%)”,”value”:”115V (+/- 5%)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”4.5 hours MAX (10% to 90% capacity) Internal batteries only”,”value”:”4.5 hours MAX (10% to 90% capacity) Internal batteries only”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade)”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”162.8″,”value”:”162.8″},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”2.2″,”value”:”2.2″},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Leakage Current”,”normalizedValue”:”Equal to 100 microamps”,”value”:”Equal to 100 microamps”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Power Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.5 hr”},{“name”:”Input Current – Maximum”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”940 J”,”value”:”940 J”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, C13″,”value”:”5-20R, C13″},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Overall Depth”,”normalizedValue”:”19 in”,”value”:”19 in”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Power Rating – Real”,”normalizedValue”:”1.92 kW”,”value”:”1.92 kW”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.