Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1 kVA”,”rank”:2,”value”:”1.0 kVA”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1 kVA”,”rank”:4,”value”:”1kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower, Wall”,”rank”:5,”value”:”Tower/Wall”},{“name”:”Wattage”,”normalizedValue”:”750 W”,”rank”:6,”value”:”750 W”},{“name”:”Input Voltage”,”normalizedValue”:”120V AC”,”rank”:7,”value”:”120V AC”},{“name”:”Output Voltage”,”normalizedValue”:”115/120V AC”,”rank”:8,”value”:”115/120V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”28 min/10 min”,”rank”:9,”value”:”28 min/10 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”Yes”,”rank”:11,”value”:”Yes”},{“name”:”Number of Outlets”,”normalizedValue”:”4″,”rank”:12,”value”:”4″},{“name”:”Special Features”,”normalizedValue”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output, Extended Runtime w/BP36V15-2U, BP36V42-3U”,”value”:”Advanced AVR Corrects Brownouts and Overvoltages, Pure Sine Wave Output, Extended Runtime w/BP36V15-2U, BP36V42-3U”},{“name”:”Height”,”normalizedValue”:”13 in”,”value”:”13 in”},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”Hz”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Depth”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, USB”,”value”:”DB9 Serial, USB”},{“name”:”Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Width”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”Input Current”,”normalizedValue”:”9.2 A”,”value”:”9.2 A”},{“name”:”Footnotes”,”normalizedValue”:”1,3,4,12,14″,”value”:”1,3,4,12,14″},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Standards”,”normalizedValue”:”CSA (Canada), FCC Part 15 Class a (USA), RoHS, UL 60601-1, UL1778″,”value”:”CSA (Canada), FCC Part 15 Class a (USA), RoHS, UL 60601-1, UL1778″},{“name”:”Includes”,”normalizedValue”:”6 ft DB9 Serial Monitoring Cable, 6 ft USB Monitoring Cable, Grade Tower UPS System, PowerAlert Software, SMART1200XLHG 1kVA/750WMedica”,”value”:”6 ft DB9 Serial Monitoring Cable, 6 ft USB Monitoring Cable, Grade Tower UPS System, PowerAlert Software, SMART1200XLHG 1kVA/750WMedica”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(4) 5-15R”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Overall Height”,”normalizedValue”:”12-1/2 in”,”value”:”12.5 in”},{“name”:”Voltage”,”normalizedValue”:”120″,”value”:”120″},{“name”:”Overall Width”,”normalizedValue”:”7-1/2 in”,”value”:”7.5 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”1000 VA/750 W”,”value”:”1000 VA/750 W”},{“name”:”Operating Temp. Range”,”normalizedValue”:”104°F (40°C)”,”value”:”104°F (40°C)”},{“name”:”Battery Type”,”normalizedValue”:”Sealed Lead Acid”,”value”:”Sealed Lead Acid (SLA)”},{“name”:”Input Connection”,”normalizedValue”:”6 ft Cord with NEMA 5-15P-HG Plug”,”value”:”6 ft Cord with NEMA 5-15P-HG Plug”},{“name”:”Housing Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC36SLT”,”value”:”RBC36SLT”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 81 and 95 are boosted by 21%”,”value”:”Input voltages between 81 and 95 are boosted by 21%”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”Wallmount (UPSWM – tower mounting kit)”,”value”:”Wallmount (UPSWM – tower mounting kit)”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”241″,”value”:”241″},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”315.2″,”value”:”315.2″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”28 min”,”value”:”28 min. (375w)”},{“name”:”Leakage Current”,”normalizedValue”:”Less than 100 microamps”,”value”:”Less than 100 microamps”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Power Factor”,”normalizedValue”:”0.8″,”value”:”0.8″},{“name”:”Grounding Lug”,”normalizedValue”:”Grounding lug”,”value”:”Grounding lug (equipotential)”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”15A”,”value”:”15A”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”115 V, 120 V”,”value”:”115V; 120V”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”750″,”value”:”750″},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-18%, +8%”,”value”:”-18%, +8%”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 126 and 143 are reduced by 9%”,”value”:”Input voltages between 126 and 143 are reduced by 9%”},{“name”:”AC Suppression Joule Rating”,”normalizedValue”:”940″,”value”:”940″},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143″},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”9.2 A”,”value”:”9.2A”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”81″,”value”:”81″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”36″,”value”:”36″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4.5 hours from 10% to 90%”,”value”:”Less than 4.5 hours from 10% to 90%”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Input Cord Length (ft.)”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports , download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Output Receptacle Details”,”normalizedValue”:”Hospital grade output receptacles”,”value”:”Hospital grade output receptacles”},{“name”:”Communications Interface”,”normalizedValue”:”USB; DB9 Serial”,”value”:”USB; DB9 Serial”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”10 min”,”value”:”10 min. (750w)”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade)”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”143″,”value”:”143″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”115V (+/- 5%)”,”value”:”115V (+/- 5%)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP36V15-2U (limit 1); BP36V27-2US (multi-pack compatible); BP36V42-3U (multi-pack compatible)”,”value”:”BP36V15-2U (limit 1); BP36V27-2US (multi-pack compatible); BP36V42-3U (multi-pack compatible)”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”162.8″,”value”:”162.8″},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”940″,”value”:”940″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 96 and 106 are boosted by 10%”,”value”:”Input voltages between 96 and 106 are boosted by 10%”},{“name”:”Output Isolation Transformer”,”normalizedValue”:”Hospital grade load isolation transformer”,”value”:”Hospital grade load isolation transformer”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”318″,”value”:”318″},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 serial cabling included”,”value”:”USB and DB9 serial cabling included”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”12.5 x 7.5 x 9.5″,”value”:”12.5 x 7.5 x 9.5″},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”Audible Alarm”,”normalizedValue”:”Factory-muted audible alarm indicates power-failure, overload and low-battery conditions”,”value”:”Factory-muted audible alarm indicates power-failure, overload and low-battery conditions”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”Package Contents”,”normalizedValue”:”SmartPro 1200XLHG UPS, SMART 1200XLHG Medical Grade Tower UPS System, PowerAlert Software and cabling, Warranty information, Instruction manual”,”value”:”SmartPro 1200XLHG UPS, SMART 1200XLHG Medical Grade Tower UPS System, PowerAlert Software and cabling, Warranty information, Instruction manual”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”104°F”,”value”:”104°F (40°C)”},{“name”:”Additional Information”,”normalizedValue”:”Ideal UPS protection for applications in medical patient-care areas where UL 2601-1 listed medical electrical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Built-in isolation transformer with faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes, Provides connected equipment with continuous power during short and long duration loss of commercial power, Expandable runtime is available with the addition of one or more external battery packs (part# BP36V27), Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation prevents shock potential and operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 1000VA / 750 watts, 34 minutes half load runtime (500VA/375 watts), 16 minutes full load runtime (1000VA/750 watts), 4 protected hospital-grade outlets; 6-ft. cord, 1-RS-232 and 1-USB serial port for network interface; SNMP compatible, SNMP compatible with separate purchase SNMPWEBSOLO ethernet adapter accessory, Complete surge protection, line isolation and EMI/RFI noise filtering, 2 year product warranty, PowerAlert unattended shutdown software and complete cabling included, 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace, Battery replacement door, Back panel grounding lug”,”value”:”Ideal UPS protection for applications in medical patient-care areas where UL 2601-1 listed medical electrical equipment is required, Maintains less than 300 microamps leakage current for UPS and all connected equipment, Built-in isolation transformer with faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes, Provides connected equipment with continuous power during short and long duration loss of commercial power, Expandable runtime is available with the addition of one or more external battery packs (part# BP36V27), Line-interactive voltage regulation corrects brownouts and overvoltages from 81 to 143 volts back to usable 120V output levels, without using battery power, Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections, Full line isolation prevents shock potential and operational problems in sensitive electronic equipment, Resistant to electrostatic discharge, Supports loads up to 1000VA / 750 watts, 34 minutes half load runtime (500VA/375 watts), 16 minutes full load runtime (1000VA/750 watts), 4 protected hospital-grade outlets; 6-ft. cord, 1-RS-232 and 1-USB serial port for network interface; SNMP compatible, SNMP compatible with separate purchase SNMPWEBSOLO ethernet adapter accessory, Complete surge protection, line isolation and EMI/RFI noise filtering, 2 year product warranty, PowerAlert unattended shutdown software and complete cabling included, 5 diagnostic LEDs indicate AC present, on battery, voltage correction, overload & battery low/replace, Battery replacement door, Back panel grounding lug”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Load Capacity”,”normalizedValue”:”1000 VA/750 W”,”value”:”1000 VA/750 W”},{“name”:”Status Indicators”,”normalizedValue”:”Includes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning”,”value”:”Includes 5 front-panel indicator LEDs to show battery charge level, AC line voltage levels, automatic voltage regulation status, UPS load level and replace battery warning”},{“name”:”Alarm”,”normalizedValue”:”On Battery, Low Battery, Overload”,”value”:”On Battery, Low Battery, Overload”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Battery Life”,”normalizedValue”:”6 yr”,”value”:”6 Year”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Applications”,”normalizedValue”:”Hospital/Medical”,”value”:”Hospital/Medical”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”750″,”value”:”750″},{“name”:”Product Compliance”,”normalizedValue”:”FCC Part 15 Class A (USA)”,”value”:”FCC Part 15 Class A (USA)”},{“name”:”Product Certifications”,”normalizedValue”:”CSA (Canada); UL 1778; UL 60601-1″,”value”:”CSA (Canada); UL 1778; UL 60601-1″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Grounding Details”,”normalizedValue”:”Grounding lug”,”value”:”Grounding lug (equipotential)”},{“name”:”Package Includes”,”normalizedValue”:”SMART1200XLHG 1kVA/750W Medical-Grade Tower UPS System;USB monitoring cable, 6 ft.;DB9 serial monitoring cable, 6 ft.;PowerAlert Software;Owner’s Manual”,”value”:”SMART1200XLHG 1kVA/750W Medical-Grade Tower UPS System;USB monitoring cable, 6 ft.;DB9 serial monitoring cable, 6 ft.;PowerAlert Software;Owner’s Manual”},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,000″,”value”:”1000″},{“name”:”Power Cord Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Input Current – Maximum”,”normalizedValue”:”9.2 A”,”value”:”9.2 A”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, USB”,”value”:”DB9 Serial, USB”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Overall Depth”,”normalizedValue”:”9-1/2 in”,”value”:”9.5 in”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage”,”value”:”Low Battery, Overload, Power Outage”},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.5 hr”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP36V15-2U, BP36V27-2US, BP36V42-3U”,”value”:”BP36V15-2U, BP36V27-2US, BP36V42-3U”},{“name”:”Power Rating – Real”,”normalizedValue”:”750 W”,”value”:”750 W”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”940 J”,”value”:”940 J”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.