UPS System, 1.96kVA, Online/Double Conversion, Out: 100/110/120/127V AC In: 100/115/120/127V AC

$1580,99

UPS System, Online Double Conversion, Power Rating 2.2 kVA, Wattage 1.8 kW, Input Voltage 100V AC, 110V AC, 115V AC, 120V AC, 127V AC, Output Voltage 100V AC, 110V AC, 120V AC, 127V AC, Backup Time (Half/Full Load) 13 min/4.5 min, Mounting Tower, Outlet Type UPS/Surge, Number of Outlets 7, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration (1) L5-20R, (6) 5-15/20R, NEMA Plug Configuration 5-20P, Automatic Volts Regulation Yes, Fax/Modem Line Protection Yes

9999 in stock

SKU: GRG9415201 Category:

Description

[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”1.96 kVA”,”rank”:4,”value”:”1.96kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”1.77 kW”,”rank”:6,”value”:”1.77 kW”},{“name”:”Input Voltage”,”normalizedValue”:”100/115/120/127V AC”,”rank”:7,”value”:”100/115/120/127V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/120/127V AC”,”rank”:8,”value”:”100/110/120/127V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”26.2 min/10.4 min”,”rank”:9,”value”:”26.2 min/10.4 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”7″,”rank”:12,”value”:”7″},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Depth”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Height”,”normalizedValue”:”10 in”,”value”:”10 in”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L5-20R, 5-15/20R”,”value”:”(6) 5-15/20R; (1) L5-20R”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Includes”,”normalizedValue”:”DB9 Cable, USB Cables”,”value”:”DB9 Cable, USB Cables”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”2.2 kVA”,”value”:”2.2 kVA”},{“name”:”Input Current”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Width”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), cUL, FCC (USA), REACH, RoHS”,”value”:”CE (Europe), cUL, FCC (USA), REACH, RoHS”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Overall Width”,”normalizedValue”:”8.43 in”,”value”:”8.43 in”},{“name”:”Overall Height”,”normalizedValue”:”13.63 in”,”value”:”13.63 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”2200 VA/1800 W”,”value”:”2200 VA/1800 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-20P Plug”,”value”:”NEMA 5-20P Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC48-SUTWR”,”value”:”RBC48-SUTWR”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,087″,”value”:”1087″},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”2.2″,”value”:”2.2″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min”,”value”:”13 min. (900w)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”259″,”value”:”259″},{“name”:”Audible Noise”,”normalizedValue”:”\u003c 50.5 dB at front side 1m”,”value”:”\u003c 50.5 dB at front side 1m”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”20A 120V”,”value”:”20A 120V”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”1.8″,”value”:”1.8″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”120V factory default”,”value”:”120V factory default”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”16 A”,”value”:”16A”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”100 V AC, 110 V AC, 120 V AC, 127 V AC”,”value”:”100V AC; 110V AC; 120V AC; 127V AC”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”2,200″,”value”:”2200″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”,”value”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 30 sec”,”value”:”4.5 min. (1800w)”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Power Factor”,”normalizedValue”:”0.82″,”value”:”0.82″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”,”value”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 150″,”value”:”2% output voltage regulation during overvoltages to 150″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 3%”,”value”:”+/- 3%”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”10.2 x 9 x 19.5″,”value”:”10.2 x 9 x 19.5″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”495″,”value”:”495″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”684″,”value”:”684″},{“name”:”Input Circuit Breakers”,”normalizedValue”:”30A”,”value”:”30A”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”100 V, 110 V, 115 V, 120 V, 127 V”,”value”:”100V; 110V; 115V; 120V; 127V”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 3 hours from 10% to 90%”,”value”:”Less than 3 hours from 10% to 90%”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.92″,”value”:”0.92″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Hot swappable batteries”,”value”:”Automatic inverter bypass; Hot swappable batteries”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”55V (33% load), 70V (70% load), 100V (100% load)”,”value”:”55V (33% load), 70V (70% load), 100V (100% load)”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”Up to 3000m”,”value”:”Up to 3000m”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Capacity Details”,”normalizedValue”:”ON LINE MODE: Maximum output capacity rating is reduced to 1620W (115V), 1530W (110V) and 1440W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts, 115V 1134 watts, 110V 1071 watts, 100V 1008 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”,”value”:”ON LINE MODE: Maximum output capacity rating is reduced to 1620W (115V), 1530W (110V) and 1440W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts, 115V 1134 watts, 110V 1071 watts, 100V 1008 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”190″,”value”:”190″},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable three-outlet load banks”,”value”:”Two switchable three-outlet load banks”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)”,”value”:”2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,800″,”value”:”1800″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”External battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”,”value”:”External battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Load Capacity”,”normalizedValue”:”2200 VA/1800 W”,”value”:”2200 VA/1800 W”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU2200XLCD 2200VA Tower UPS, PowerAlert Software CD, USB and DB9 Cabling, Owner’s Manual with Warranty Information, EPO (Emergency Power Off) Cabling”,”value”:”SmartOnline SU2200XLCD 2200VA Tower UPS, PowerAlert Software CD, USB and DB9 Cabling, Owner’s Manual with Warranty Information, EPO (Emergency Power Off) Cabling”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”3 hr”,”value”:”3 Hour”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Input Cord Length (ft.)”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Product Compliance”,”normalizedValue”:”CE (Europe); FCC (USA)”,”value”:”CE (Europe); FCC (USA)”},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Power Factor (Input)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”682″,”value”:”682″},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”13.63 x 8.43 x 16.23″,”value”:”13.630 x 8.430 x 16.230″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,960″,”value”:”1960″},{“name”:”Product Certifications”,”normalizedValue”:”cUL Listed”,”value”:”cUL Listed”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”1,770″,”value”:”1770″},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Package Includes”,”normalizedValue”:”1960VA 1770W 120V Double-Conversion UPS;USB cable;DB9 cable;Quick Start Guide”,”value”:”1960VA 1770W 120V Double-Conversion UPS;USB cable;DB9 cable;Quick Start Guide”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP96V”,”value”:”BP96V”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L5-20R”,”value”:”5-20R, L5-20R”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, USB”,”value”:”DB9 Serial, USB”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Power Rating – Real”,”normalizedValue”:”1.77 kW”,”value”:”1.77 kW”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Overall Depth”,”normalizedValue”:”16.2 in”,”value”:”16.2 in”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”744-A4313″,”value”:”744-A4313″},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”,”value”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”},{“name”:”Input Current – Maximum”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”190 J”,”value”:”190 J”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 1.96kVA, Online/Double Conversion, Out: 100/110/120/127V AC In: 100/115/120/127V AC”