Description
[{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”1.96 kVA”,”rank”:4,”value”:”1.96kVA”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”1.77 kW”,”rank”:6,”value”:”1.77 kW”},{“name”:”Input Voltage”,”normalizedValue”:”100/115/120/127V AC”,”rank”:7,”value”:”100/115/120/127V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/120/127V AC”,”rank”:8,”value”:”100/110/120/127V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”26.2 min/10.4 min”,”rank”:9,”value”:”26.2 min/10.4 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”7″,”rank”:12,”value”:”7″},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Depth”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Height”,”normalizedValue”:”10 in”,”value”:”10 in”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”L5-20R, 5-15/20R”,”value”:”(6) 5-15/20R; (1) L5-20R”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Includes”,”normalizedValue”:”DB9 Cable, USB Cables”,”value”:”DB9 Cable, USB Cables”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”2.2 kVA”,”value”:”2.2 kVA”},{“name”:”Input Current”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-20P”,”value”:”5-20P”},{“name”:”Width”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), cUL, FCC (USA), REACH, RoHS”,”value”:”CE (Europe), cUL, FCC (USA), REACH, RoHS”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Overall Width”,”normalizedValue”:”8.43 in”,”value”:”8.43 in”},{“name”:”Overall Height”,”normalizedValue”:”13.63 in”,”value”:”13.63 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”2200 VA/1800 W”,”value”:”2200 VA/1800 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-20P Plug”,”value”:”NEMA 5-20P Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Extended runtime supported via optional external battery packs”,”value”:”Extended runtime supported via optional external battery packs”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC48-SUTWR”,”value”:”RBC48-SUTWR”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”1,087″,”value”:”1087″},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”2.2″,”value”:”2.2″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”13 min”,”value”:”13 min. (900w)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”259″,”value”:”259″},{“name”:”Audible Noise”,”normalizedValue”:”\u003c 50.5 dB at front side 1m”,”value”:”\u003c 50.5 dB at front side 1m”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”20A 120V”,”value”:”20A 120V”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”1.8″,”value”:”1.8″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”,”value”:”Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”120V factory default”,”value”:”120V factory default”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”16 A”,”value”:”16A”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”100 V AC, 110 V AC, 120 V AC, 127 V AC”,”value”:”100V AC; 110V AC; 120V AC; 127V AC”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”2,200″,”value”:”2200″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”,”value”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 30 sec”,”value”:”4.5 min. (1800w)”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Power Factor”,”normalizedValue”:”0.82″,”value”:”0.82″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”,”value”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”,”value”:”Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options”},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 150″,”value”:”2% output voltage regulation during overvoltages to 150″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 3%”,”value”:”+/- 3%”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”10.2 x 9 x 19.5″,”value”:”10.2 x 9 x 19.5″},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”495″,”value”:”495″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”684″,”value”:”684″},{“name”:”Input Circuit Breakers”,”normalizedValue”:”30A”,”value”:”30A”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”100 V, 110 V, 115 V, 120 V, 127 V”,”value”:”100V; 110V; 115V; 120V; 127V”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 3 hours from 10% to 90%”,”value”:”Less than 3 hours from 10% to 90%”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.92″,”value”:”0.92″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Hot swappable batteries”,”value”:”Automatic inverter bypass; Hot swappable batteries”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”55V (33% load), 70V (70% load), 100V (100% load)”,”value”:”55V (33% load), 70V (70% load), 100V (100% load)”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”Up to 3000m”,”value”:”Up to 3000m”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output Capacity Details”,”normalizedValue”:”ON LINE MODE: Maximum output capacity rating is reduced to 1620W (115V), 1530W (110V) and 1440W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts, 115V 1134 watts, 110V 1071 watts, 100V 1008 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”,”value”:”ON LINE MODE: Maximum output capacity rating is reduced to 1620W (115V), 1530W (110V) and 1440W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 1260 watts, 115V 1134 watts, 110V 1071 watts, 100V 1008 watts) OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and \u003e150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”190″,”value”:”190″},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable three-outlet load banks”,”value”:”Two switchable three-outlet load banks”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Undervoltage Correction”,”normalizedValue”:”2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)”,”value”:”2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,800″,”value”:”1800″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Expandable Runtime Description”,”normalizedValue”:”External battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”,”value”:”External battery configurations require the use of Tripp Lite’s External Battery Configuration Software, see manual for details”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Load Capacity”,”normalizedValue”:”2200 VA/1800 W”,”value”:”2200 VA/1800 W”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU2200XLCD 2200VA Tower UPS, PowerAlert Software CD, USB and DB9 Cabling, Owner’s Manual with Warranty Information, EPO (Emergency Power Off) Cabling”,”value”:”SmartOnline SU2200XLCD 2200VA Tower UPS, PowerAlert Software CD, USB and DB9 Cabling, Owner’s Manual with Warranty Information, EPO (Emergency Power Off) Cabling”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”3 hr”,”value”:”3 Hour”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Input Cord Length (ft.)”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Product Compliance”,”normalizedValue”:”CE (Europe); FCC (USA)”,”value”:”CE (Europe); FCC (USA)”},{“name”:”AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Power Factor (Input)”,”normalizedValue”:”0.99″,”value”:”0.99″},{“name”:”Online Mode Heat Dissipation (BTU/Hr) @ Full Load”,”normalizedValue”:”682″,”value”:”682″},{“name”:”Unit Dimensions (hwd / in.)”,”normalizedValue”:”13.63 x 8.43 x 16.23″,”value”:”13.630 x 8.430 x 16.230″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,960″,”value”:”1960″},{“name”:”Product Certifications”,”normalizedValue”:”cUL Listed”,”value”:”cUL Listed”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”1,770″,”value”:”1770″},{“name”:”UPS Applications”,”normalizedValue”:”Mission Critical Applications”,”value”:”Mission Critical Applications”},{“name”:”Package Includes”,”normalizedValue”:”1960VA 1770W 120V Double-Conversion UPS;USB cable;DB9 cable;Quick Start Guide”,”value”:”1960VA 1770W 120V Double-Conversion UPS;USB cable;DB9 cable;Quick Start Guide”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP96V”,”value”:”BP96V”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-20R, L5-20R”,”value”:”5-20R, L5-20R”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, USB”,”value”:”DB9 Serial, USB”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Power Rating – Real”,”normalizedValue”:”1.77 kW”,”value”:”1.77 kW”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Overall Depth”,”normalizedValue”:”16.2 in”,”value”:”16.2 in”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”7″,”value”:”7″},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”744-A4313″,”value”:”744-A4313″},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”,”value”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”},{“name”:”Input Current – Maximum”,”normalizedValue”:”16 A”,”value”:”16 A”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”190 J”,”value”:”190 J”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.