UPS System, 1.5kVA, Online/Double Conversion, Out: 100/110/115/120/127V AC In: 100/115/120/127V AC

$1185,99

UPS System, Online Double Conversion, Power Rating 1.5 kVA, Wattage 1.35 kW, Input Voltage 100V AC, 110V AC, 115V AC, 120V AC, 127V AC, Output Voltage 100V AC, 110V AC, 115V AC, 120V AC, 127V AC, Backup Time (Half/Full Load) 14 min/4.5 min, Mounting Rack, Outlet Type UPS/Surge, Number of Outlets 6, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation Yes, Fax/Modem Line Protection Yes, Transfer Time 0 msec

9999 in stock

SKU: GRG9415183 Category:

Description

[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1.5 kVA”,”rank”:2,”value”:”1.5 kVA”},{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Online, Double Conversion”,”rank”:3,”value”:”Online/Double Conversion”},{“name”:”Power Rating”,”normalizedValue”:”1.5 kVA”,”rank”:4,”value”:”1.5kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”1.35 kW”,”rank”:6,”value”:”1.35 kW”},{“name”:”Input Voltage”,”normalizedValue”:”100/115/120/127V AC”,”rank”:7,”value”:”100/115/120/127V AC”},{“name”:”Output Voltage”,”normalizedValue”:”100/110/115/120/127V AC”,”rank”:8,”value”:”100/110/115/120/127V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”16.5 min/5.9 min”,”rank”:9,”value”:”16.5 min/5.9 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”(6) 5-15R”},{“name”:”Height”,”normalizedValue”:”10 in”,”value”:”10 in”},{“name”:”Width”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Depth”,”normalizedValue”:”20 in”,”value”:”20 in”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial, EPO, USB”,”value”:”DB9 Serial, EPO, USB”},{“name”:”Includes”,”normalizedValue”:”DB9 Cable, USB Cables”,”value”:”DB9 Cable, USB Cables”},{“name”:”Transfer Time”,”normalizedValue”:”0 msec”,”value”:”0 msec”},{“name”:”Input Current”,”normalizedValue”:”12 A”,”value”:”12 A”},{“name”:”Special Features”,”normalizedValue”:”Hot-Swappable Batteries”,”value”:”Hot-Swappable Batteries”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), cUL, FCC (USA), REACH, RoHS, UL”,”value”:”CE (Europe), cUL, FCC (USA), REACH, RoHS, UL”},{“name”:”Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”Overall Height”,”normalizedValue”:”9.93 in”,”value”:”9.93 in”},{“name”:”Overall Width”,”normalizedValue”:”6.3 in”,”value”:”6.3 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”1500 VA/1350 W”,”value”:”1500 VA/1350 W”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-15P Plug”,”value”:”NEMA 5-15P Plug”},{“name”:”Battery Type”,”normalizedValue”:”VRLA”,”value”:”VRLA”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”814″,”value”:”814″},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”1.35″,”value”:”1.35″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”1,350″,”value”:”1350″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”55V (33% load), 70V (70% load), 100V (100% load)”,”value”:”55V (33% load), 70V (70% load), 100V (100% load)”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/- 10%”,”value”:”+/- 10%”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”12 A”,”value”:”12A”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”495″,”value”:”495″},{“name”:”AC Economy Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.97″,”value”:”0.97″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC48-SUTWR”,”value”:”RBC48-SUTWR”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 3 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 3 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 30 sec”,”value”:”4.5 min. (1350w)”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”570″,”value”:”570″},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”,”value”:”Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 3%”,”value”:”+/- 3%”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Communications Cable”,”normalizedValue”:”USB and DB9 cabling included”,”value”:”USB and DB9 cabling included”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”,”value”:”ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY REGULATION / CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Hot swappable batteries”,”value”:”Automatic inverter bypass; Hot swappable batteries”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”14 min”,”value”:”14 min. (675w)”},{“name”:”Audible Noise”,”normalizedValue”:”< 50.5 dB at front side 1m","value":"< 50.5 dB at front side 1m"},{"name":"PowerAlert Software","normalizedValue":"For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert","value":"For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert"},{"name":"Nominal Input Voltage(s) Supported","normalizedValue":"100 V AC, 110 V AC, 120 V AC, 127 V AC","value":"100V AC; 110V AC; 120V AC; 127V AC"},{"name":"Input Circuit Breakers","normalizedValue":"15A","value":"15A"},{"name":"Expandable Runtime Description","normalizedValue":"External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details","value":"External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details"},{"name":"Crest Factor","normalizedValue":"0.125694444444444","value":"0.125694444444444"},{"name":"Undervoltage Correction","normalizedValue":"2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)","value":"2% output voltage regulation during undervoltages to 55V (33% load), 70V (70% load), 100V (100% load)"},{"name":"EMI / RFI AC Noise Suppression","normalizedValue":"Yes","value":"Yes"},{"name":"Front Panel LCD Display","normalizedValue":"Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options","value":"Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options"},{"name":"Alarm Cancel Operation","normalizedValue":"Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available","value":"Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available"},{"name":"Individually Controllable Load Banks","normalizedValue":"Yes","value":"Yes"},{"name":"Nominal Output Voltage(s) Supported","normalizedValue":"100 V, 110 V, 115 V, 120 V, 127 V","value":"100V; 110V; 115V; 120V; 127V"},{"name":"Expandable Battery Runtime","normalizedValue":"Extended runtime supported via optional external battery packs","value":"Extended runtime supported via optional external battery packs"},{"name":"Output Capacity Details","normalizedValue":"ON LINE MODE: Maximum output capacity rating is reduced to 1215W (115V), 1148W (110V) and 1080W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts, 115V 851 watts, 110V 804 watts, 100V 756 watts). OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”,”value”:”ON LINE MODE: Maximum output capacity rating is reduced to 1215W (115V), 1148W (110V) and 1080W (100V); FREQUENCY REGULATION / CONVERSION MODE: Maximum output ratings are reduced in frequency regulation / conversion mode (127/120V 945 watts, 115V 851 watts, 110V 804 watts, 100V 756 watts). OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)”},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Load Management Receptacles”,”normalizedValue”:”Two switchable three-outlet load banks”,”value”:”Two switchable three-outlet load banks”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”120V factory default”,”value”:”120V factory default”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, SNMPWEBCARD, TLNETCARD, RELAYIOCARD, MODBUSCARD”,”value”:”SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1.5″,”value”:”1.5″},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fan”},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”,”value”:”BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible)”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 2%”,”value”:”+/- 2%”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”Up to 3000m”,”value”:”Up to 3000m”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning”,”value”:”Online, double-conversion power conditioning”},{“name”:”AC Economy Mode BTU / Hr. (Full Load)”,”normalizedValue”:”142″,”value”:”142″},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”259″,”value”:”259″},{“name”:”Overvoltage Correction”,”normalizedValue”:”2% output voltage regulation during overvoltages to 150″,”value”:”2% output voltage regulation during overvoltages to 150″},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”48″,”value”:”48″},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”,”value”:”Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”10.2 x 9 x 19.5″,”value”:”10.2 x 9 x 19.5″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”512″,”value”:”512″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”150″,”value”:”150″},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bypass Switch”,”normalizedValue”:”Automatic”,”value”:”Automatic”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”3 hr”,”value”:”3 Hour”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Package Contents”,”normalizedValue”:”SmartOnline SU1500XL 1500VA Tower UPS, PowerAlert Software CD, Owner’s Manual, EPO (Emergency Power Off) Cabling, USB Cable, Serial Cable”,”value”:”SmartOnline SU1500XL 1500VA Tower UPS, PowerAlert Software CD, Owner’s Manual, EPO (Emergency Power Off) Cabling, USB Cable, Serial Cable”},{“name”:”Load Capacity”,”normalizedValue”:”1500 VA/1350 W”,”value”:”1500 VA/1350 W”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Emergency Power OFF”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Network Management”,”normalizedValue”:”SNMP Manageable”,”value”:”SNMP Manageable”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”6″,”value”:”6″},{“name”:”Power Rating – Real”,”normalizedValue”:”1.35 kW”,”value”:”1.35 kW”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Power Cord Length”,”normalizedValue”:”10 ft”,”value”:”10 ft”},{“name”:”External Battery Compatible”,”normalizedValue”:”External Battery Pack Compatible”,”value”:”External Battery Pack Compatible”},{“name”:”Overall Depth”,”normalizedValue”:”22.4 in”,”value”:”22.4 in”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Replacement Battery Part Number”,”normalizedValue”:”744-A4312″,”value”:”744-A4312″},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”190 J”,”value”:”190 J”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr”,”value”:”2 yr”},{“name”:”Input Current – Maximum”,”normalizedValue”:”12 A”,”value”:”12 A”},{“name”:”Output Ports Included”,”normalizedValue”:”DB9 Serial, SNMP, USB”,”value”:”DB9 Serial, SNMP, USB”},{“name”:”Receptacle Configuration”,”normalizedValue”:”5-15R”,”value”:”5-15R”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”,”value”:”Low Battery, Overload, Power Outage, Shutdown, UPS Fault, UPS Startup”},{“name”:”External Battery Pack Part Number”,”normalizedValue”:”BP48V”,”value”:”BP48V”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 1.5kVA, Online/Double Conversion, Out: 100/110/115/120/127V AC In: 100/115/120/127V AC”