UPS System, 1.5kVA, Line Interactive, Out: 220/230/240V AC In: 230V AC

$530,99

UPS System, Line Interactive, Power Rating 1.5 kVA, Wattage 900 W, Input Voltage 230V AC, Output Voltage 230V AC, Backup Time (Half/Full Load) 12 min/4.5 min, Mounting Rack, Outlet Type UPS/Surge, Number of Outlets 8, Medical Grade Not Medical Grade Approved, NEMA Receptacle Configuration C13, NEMA Plug Configuration 5-15P, Automatic Volts Regulation Yes, Fax/Modem Line Protection Yes, Transfer Time 2 to 4 msec, Width 17 in, Depth 11 in, Height 4 in, Cord Length No Cord, Display Type LCD

9999 in stock

SKU: GRG6166395 Category:

Description

[{“name”:”CAD Available”,”normalizedValue”:”Yes”,”rank”:1,”value”:”Yes”},{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1.5 kVA”,”rank”:2,”value”:”1.5 kVA”},{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Power Rating”,”normalizedValue”:”1.5 kVA”,”rank”:4,”value”:”1.5kVA”},{“name”:”Mounting”,”normalizedValue”:”Rack”,”rank”:5,”value”:”Rack”},{“name”:”Wattage”,”normalizedValue”:”900 W”,”rank”:6,”value”:”900 W”},{“name”:”Input Voltage”,”normalizedValue”:”230V AC”,”rank”:7,”value”:”230V AC”},{“name”:”Output Voltage”,”normalizedValue”:”220/230/240V AC”,”rank”:8,”value”:”220/230/240V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”12 min/4.5 min”,”rank”:9,”value”:”12 min/4.5 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”8″,”rank”:12,”value”:”8″},{“name”:”Cord Length”,”normalizedValue”:”No Cord”,”value”:”No Cord”},{“name”:”Ports”,”normalizedValue”:”Coaxial, DB9, DSL/Ethernet, TEL, USB”,”value”:”Coaxial, DB9, DSL/Ethernet, TEL, USB”},{“name”:”Input Current”,”normalizedValue”:”4.4 A”,”value”:”4.4 A”},{“name”:”Depth”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Display Type”,”normalizedValue”:”LCD”,”value”:”LCD”},{“name”:”Height”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Special Features”,”normalizedValue”:”Cold Start Operation Supported”,”value”:”Cold Start Operation Supported”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Width”,”normalizedValue”:”11 in”,”value”:”11 in”},{“name”:”Includes”,”normalizedValue”:”(2) C13 to C14 Cables, (2) Tower/Rackmount Brackets, Coax Cable, USB and Phone (RJ11) Cables”,”value”:”(2) C13 to C14 Cables, (2) Tower/Rackmount Brackets, Coax Cable, USB and Phone (RJ11) Cables”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Standards”,”normalizedValue”:”CE (Europe), EN 62040-1, EN 62040-2, GOST (Russia), RoHS, SASO (Saudi Arabia)”,”value”:”CE (Europe), EN 62040-1, EN 62040-2, GOST (Russia), RoHS, SASO (Saudi Arabia)”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”C13″,”value”:”(8) C13″},{“name”:”Footnotes”,”normalizedValue”:”USB, DB9, and TEL/DSL/ethernet/coax”,”value”:”USB, DB9, and TEL/DSL/ethernet/coax”},{“name”:”Overall Height”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Overall Width”,”normalizedValue”:”17-1/4 in”,”value”:”17.25 in”},{“name”:”Capacity – Batteries”,”normalizedValue”:”1500 VA/900 W”,”value”:”1500 VA/900 W”},{“name”:”Battery Type”,”normalizedValue”:”Sealed Lead Acid”,”value”:”Sealed Lead Acid (SLA)”},{“name”:”Input Connection”,”normalizedValue”:”NEMA 5-15P Plug”,”value”:”NEMA 5-15P Plug”},{“name”:”Housing Material”,”normalizedValue”:”ABS”,”value”:”ABS”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”Rack Height”,”normalizedValue”:”2 U”,”value”:”2U”},{“name”:”Cooling Method”,”normalizedValue”:”Convection”,”value”:”Convection”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user-replaceable internal battery cartridge”,”value”:”Hot-swappable, user-replaceable internal battery cartridge”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”UPS Input Connection Description”,”normalizedValue”:”Chassis mounted C14 inlet accepts user-supplied AC power cord with country specific cordsets”,”value”:”Chassis mounted C14 inlet accepts user-supplied AC power cord with country specific cordsets”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 177 and 199 are boosted by 14%”,”value”:”Input voltages between 177 and 199 are boosted by 14%”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”89″,”value”:”89″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery status; Alarm can be disabled entirely via front panel LCD interface (see manual)”,”value”:”Audible alarm indicates power-failure and low-battery status; Alarm can be disabled entirely via front panel LCD interface (see manual)”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 144 to 282″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 144 to 282″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Battery Access”,”normalizedValue”:”Includes battery access door”,”value”:”Includes battery access door”},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”133″,”value”:”133″},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”282″,”value”:”282″},{“name”:”UPS Certifications”,”normalizedValue”:”CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia)”,”value”:”CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia)”},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”4 min 30 sec”,”value”:”4.5 min. (900w)”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”4.4 A”,”value”:”4.4A”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.5 x 17.25 x 10.5″,”value”:”3.5 x 17.25 x 10.5″},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”IMPORTANT BATTERY REPLACEMENT INFORMATION \u003e If your SMX1500LCD UPS has no battery replacement door, please contact a local electronics repair technician to source and install a matching replacement battery; If your SMX1500LCD UPS is equipped with a battery access door, please order Tripp Lite RBC1500 (quantity 1) replacement battery”,”value”:”IMPORTANT BATTERY REPLACEMENT INFORMATION \u003e If your SMX1500LCD UPS has no battery replacement door, please contact a local electronics repair technician to source and install a matching replacement battery; If your SMX1500LCD UPS is equipped with a battery access door, please order Tripp Lite RBC1500 (quantity 1) replacement battery”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”UPS Certification Details”,”normalizedValue”:”CE Class A (EMI); CE IEC 62040-1-1, 62040-1-2″,”value”:”CE Class A (EMI); CE IEC 62040-1-1, 62040-1-2″},{“name”:”Minimum Required Rack Depth (inches)”,”normalizedValue”:”13.5″,”value”:”13.5″},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 144 and 176 are boosted by 30%”,”value”:”Input voltages between 144 and 176 are boosted by 30%”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”144″,”value”:”144″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”230 V AC”,”value”:”230V AC”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”LED Indicators”,”normalizedValue”:”Front panel LCD display”,”value”:”Front panel LCD display”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”Communications Cable”,”normalizedValue”:”USB cabling included”,”value”:”USB cabling included”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions”,”value”:”Supports detailed monitoring of UPS and site power conditions”},{“name”:”Primary Form Factor”,”normalizedValue”:”Rackmount”,”value”:”Rackmount”},{“name”:”UPS Dataline Suppression Details”,”normalizedValue”:”RJ11 telephone cable included”,”value”:”RJ11 telephone cable included”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”5A”,”value”:”5A”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”360″,”value”:”360″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”4.5 hours from 10% to 90%”,”value”:”4.5 hours from 10% to 90%”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”,”value”:”1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1.5″,”value”:”1.5″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”220 V, 230 V, 240 V”,”value”:”220V; 230V; 240V”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.96″,”value”:”0.96″},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”12 min”,”value”:”12 min. (450w)”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-18%, +8%”,”value”:”-18%, +8%”},{“name”:”Switches”,”normalizedValue”:”ON/OFF/MODE button provides UPS on/off power control (long-press) and advances the LCD screen display (short tap); MUTE/ENTER button provides temporary alarm cancel, plus selection and confirmation of on-screen configuration options”,”value”:”ON/OFF/MODE button provides UPS on/off power control (long-press) and advances the LCD screen display (short tap); MUTE/ENTER button provides temporary alarm cancel, plus selection and confirmation of on-screen configuration options”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”267″,”value”:”267″},{“name”:”Battery Mode BTU / Hr. (Full Load)”,”normalizedValue”:”542″,”value”:”542″},{“name”:”Included Mounting Accessory Description”,”normalizedValue”:”Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placement”,”value”:”Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placement”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Included Output Power Cables”,”normalizedValue”:”Includes 2 C13 to C14 output power cables.”,”value”:”Includes 2 C13 to C14 output power cables.”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled); DB9 Serial”,”value”:”USB (HID enabled); DB9 Serial”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”2 post 19 inch rackmount; 4 post 19 inch rackmount; Tower”,”value”:”2 post 19 inch rackmount; 4 post 19 inch rackmount; Tower”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Automatic frequency selection”,”value”:”Automatic frequency selection”},{“name”:”Hot-Swap PDU options”,”normalizedValue”:”PDUBHV10 (2U / 8 C13 outlets)”,”value”:”PDUBHV10 (2U / 8 C13 outlets)”},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 245 and 282 are reduced by 12%”,”value”:”Input voltages between 245 and 282 are reduced by 12%”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Backlighted LCD screen offers detailed UPS status information, configuration options and Error message reporting; STATUS INFORMATION includes Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load Percentage, Output Load Wattage, Battery Charge Percentage, Graphical 5-Bar Battery Charge Level and UPS Operating Mode Display; CONFIGURATION OPTIONS include Power Sensitivity, LCD Status Information Scrolling, Alarm Disable, LCD Brightness and Self Test / REPORTED ERROR MESSAGES include Replace-Battery and Overload conditions; LCD Screen rotates for vertical or horizontal UPS placement”,”value”:”Backlighted LCD screen offers detailed UPS status information, configuration options and Error message reporting; STATUS INFORMATION includes Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load Percentage, Output Load Wattage, Battery Charge Percentage, Graphical 5-Bar Battery Charge Level and UPS Operating Mode Display; CONFIGURATION OPTIONS include Power Sensitivity, LCD Status Information Scrolling, Alarm Disable, LCD Brightness and Self Test / REPORTED ERROR MESSAGES include Replace-Battery and Overload conditions; LCD Screen rotates for vertical or horizontal UPS placement”},{“name”:”Dataline Protection”,”normalizedValue”:”RJ-11″,”value”:”RJ-11″},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”8 hr”,”value”:”8 Hour”},{“name”:”Load Capacity”,”normalizedValue”:”1500 VA/900 W”,”value”:”1500 VA/900 W”},{“name”:”Additional Information”,”normalizedValue”:”Appearance: Attractive black color schemeOutput voltage regulation: Battery Mode: PWM sine wave 230V +/-5%Output frequency regulation: Line Mode: Passes line frequency of 50/60Hz +/-10%, Battery Mode: Inverter output regulated to 50/60Hz +/-0.5Hz”,”value”:”Appearance: Attractive black color schemeOutput voltage regulation: Battery Mode: PWM sine wave 230V +/-5%Output frequency regulation: Line Mode: Passes line frequency of 50/60Hz +/-10%, Battery Mode: Inverter output regulated to 50/60Hz +/-0.5Hz”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro SMX1500LCD 1500VA Tower/Rack Mountable Digital UPS, SMX1500LCD Digital UPS System, USB cable, phone (RJ11) cable and coax cable, 2 C13-to-C14 jumper cables, 2 tower/rackmount brackets, Owner’s manual with warranty information”,”value”:”SmartPro SMX1500LCD 1500VA Tower/Rack Mountable Digital UPS, SMX1500LCD Digital UPS System, USB cable, phone (RJ11) cable and coax cable, 2 C13-to-C14 jumper cables, 2 tower/rackmount brackets, Owner’s manual with warranty information”},{“name”:”Form Factor”,”normalizedValue”:”Tower, Rack-mountable”,”value”:”Rack-mountable, Tower”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert Software”,”value”:”PowerAlert Software”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Chemistry”,”normalizedValue”:”Valve Regulated Lead Acid”,”value”:”Valve Regulated Lead Acid”},{“name”:”USB”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Certifications”,”normalizedValue”:”GOST (Russia); EN 62040-1; EN 62040-2″,”value”:”GOST (Russia); EN 62040-1; EN 62040-2″},{“name”:”Output Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”Product Compliance”,”normalizedValue”:”SASO (Saudi Arabia); CE (Europe)”,”value”:”SASO (Saudi Arabia); CE (Europe)”},{“name”:”Output Capacity (Watts)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”,”value”:”Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection”},{“name”:”UPS Applications”,”normalizedValue”:”Home/Office Desktop; Audio/Video”,”value”:”Home/Office Desktop; Audio/Video”},{“name”:”Package Includes”,”normalizedValue”:”SMX1500LCD 1500VA 900W 230V Line-Interactive UPS with 8 Outlets;USB cable;RJ11 cable;(2) C13 to C14 power cables;Tower/rack mounting hardware;Owner’s manual”,”value”:”SMX1500LCD 1500VA 900W 230V Line-Interactive UPS with 8 Outlets;USB cable;RJ11 cable;(2) C13 to C14 power cables;Tower/rack mounting hardware;Owner’s manual”},{“name”:”Input Frequency”,”normalizedValue”:”±3Hz”,”value”:”±3Hz”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Audible Alarm Conditions”,”normalizedValue”:”Low Battery, Power Outage”,”value”:”Low Battery, Power Outage”},{“name”:”Includes Battery”,”normalizedValue”:”Battery Included”,”value”:”Battery Included”},{“name”:”Power Rating – Real”,”normalizedValue”:”900 W”,”value”:”900 W”},{“name”:”Automatic Voltage Regulation”,”normalizedValue”:”Includes Automatic Voltage Regulation”,”value”:”Includes Automatic Voltage Regulation”},{“name”:”Data Line Protection”,”normalizedValue”:”Includes Data Line Surge Protection”,”value”:”Includes Data Line Surge Protection”},{“name”:”Surge Suppression Rating”,”normalizedValue”:”360 J”,”value”:”360 J”},{“name”:”Manufacturer Warranty”,”normalizedValue”:”2 yr, 3 yr (Registration)”,”value”:”2 yr, 3 yr Registration”},{“name”:”Number of Outlets – Surge Only”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Battery Recharge Time”,”normalizedValue”:”4 hr 30 min”,”value”:”4.5 hr”},{“name”:”External Battery Compatible”,”normalizedValue”:”Not External Battery Pack Compatible”,”value”:”Not External Battery Pack Compatible”},{“name”:”Power Cord Length”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Input Current – Maximum”,”normalizedValue”:”4.4 A”,”value”:”4.4 A”},{“name”:”Overall Depth”,”normalizedValue”:”10-1/2 in”,”value”:”10.5 in”},{“name”:”Receptacle Configuration”,”normalizedValue”:”C13″,”value”:”C13″},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Output Ports Included”,”normalizedValue”:”Coaxial, DB9 Serial, DSL/Ethernet, USB”,”value”:”Coaxial, DB9 Serial, DSL/Ethernet, USB”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 1.5kVA, Line Interactive, Out: 220/230/240V AC In: 230V AC”