UPS System, 1.5kVA, 6 Outlets, Tower, Out: 220/230/240V AC , In:230V AC, Tripp Lite, Mfr#: SMARTINT1500

$699,99

UPS System, Line Interactive, Power Rating 1.5 kVA, Wattage 940 W, Input Voltage 230V AC, Output Voltage 220V AC, 230V AC, 240V AC, Backup Time (Half/Full Load) 20 min/7 min, Mounting Tower, Outlet Type UPS/Surge, Number of Outlets 6, Medical Grade No, NEMA Receptacle Configuration C13, NEMA Plug Configuration C14, Automatic Volts Regulation Yes, Fax/Modem Line Protection No, Transfer Time 2 to 4 msec, Width 8 in, Depth 9 in, Height 13 in, Cord Length No Cord, Display Type LED, 50/60 Hz Hz

Out of stock

SKU: GRG9415052 Category:

Description

[{“name”:”VA Rating – UPS Systems”,”normalizedValue”:”1.5 kVA”,”rank”:2,”value”:”1.5 kVA”},{“name”:”Item”,”normalizedValue”:”UPS System”,”rank”:2,”value”:”UPS System”},{“name”:”UPS Type”,”normalizedValue”:”Line Interactive”,”rank”:3,”value”:”Line Interactive”},{“name”:”Watts – UPS Systems”,”normalizedValue”:”940 W”,”rank”:3,”value”:”940.0 W”},{“name”:”Input Voltage – UPS Systems”,”normalizedValue”:”230V AC”,”rank”:4,”value”:”230V AC”},{“name”:”Power Rating”,”normalizedValue”:”1.5 kVA”,”rank”:4,”value”:”1.5kVA”},{“name”:”Output Voltage – UPS Systems”,”normalizedValue”:”220V AC, 230V AC, 240V AC”,”rank”:5,”value”:”220V AC, 230V AC, 240V AC”},{“name”:”Mounting”,”normalizedValue”:”Tower”,”rank”:5,”value”:”Tower”},{“name”:”Wattage”,”normalizedValue”:”940 W”,”rank”:6,”value”:”940 W”},{“name”:”Input Voltage”,”normalizedValue”:”230V AC”,”rank”:7,”value”:”230V AC”},{“name”:”Outlet Type – UPS Systems”,”normalizedValue”:”UPS/Surge”,”rank”:8,”value”:”UPS/Surge”},{“name”:”Output Voltage”,”normalizedValue”:”220/230/240V AC”,”rank”:8,”value”:”220/230/240V AC”},{“name”:”Backup Time (Half/Full Load)”,”normalizedValue”:”20 min/7 min”,”rank”:9,”value”:”20 min/7 min”},{“name”:”Outlet Type”,”normalizedValue”:”UPS/Surge”,”rank”:10,”value”:”UPS/Surge”},{“name”:”Medical Grade”,”normalizedValue”:”No”,”rank”:11,”value”:”No”},{“name”:”Number of Outlets”,”normalizedValue”:”6″,”rank”:12,”value”:”6″},{“name”:”Watts”,”normalizedValue”:”940″,”value”:”940W”},{“name”:”Special Features”,”normalizedValue”:”Hot Swappable Batteries”,”value”:”Hot Swappable Batteries”},{“name”:”NEMA Plug Configuration”,”normalizedValue”:”C14″,”value”:”C14″},{“name”:”Cord Length”,”normalizedValue”:”No Cord”,”value”:”No Cord”},{“name”:”Display Type”,”normalizedValue”:”LED”,”value”:”LED”},{“name”:”Ports”,”normalizedValue”:”DB9 Serial”,”value”:”DB9 Serial”},{“name”:”Height”,”normalizedValue”:”13 in”,”value”:”13 in”},{“name”:”Fax/Modem Line Protection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Mounting – UPS Systems”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Width”,”normalizedValue”:”8 in”,”value”:”8 in”},{“name”:”Includes”,”normalizedValue”:”(2) DB9 Monitoring Cables, (2) IEC-320 C13 to C14 Power Cables, PowerAlert Unattended Shutdown and UPS/Power Monitoring Software”,”value”:”(2) DB9 Monitoring Cables, (2) IEC-320 C13 to C14 Power Cables, PowerAlert Unattended Shutdown and UPS/Power Monitoring Software”},{“name”:”NEMA Receptacle Configuration”,”normalizedValue”:”C13″,”value”:”C13″},{“name”:”Depth”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Input Current”,”normalizedValue”:”6.5 A”,”value”:”6.5 A”},{“name”:”Transfer Time”,”normalizedValue”:”2 to 4 msec”,”value”:”2 to 4 msec”},{“name”:”Automatic Volts Regulation”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Phase”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Standards”,”normalizedValue”:”UL”,”value”:”UL”},{“name”:”Green Certification or Other Recognition”,”normalizedValue”:”CE EN62040 listed, UL, cUL, GOST, IRAM, SASO”,”value”:”CE EN62040 listed, UL, cUL, GOST, IRAM, SASO”},{“name”:”Capacity – Batteries”,”normalizedValue”:”1500 VA/940 W”,”value”:”1500 VA/940 W”},{“name”:”Backup/Run Time (Full Load)”,”normalizedValue”:”7 Minute/20 Minute”,”value”:”7 Minute/20 Minute”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPSâ„¢s built-in DB9 port, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPSâ„¢s built-in DB9 port, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”940″,”value”:”940″},{“name”:”UPS Certifications”,”normalizedValue”:”Tested to UL1778 (USA); Tested to CSA (Canada); CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina)”,”value”:”Tested to UL1778 (USA); Tested to CSA (Canada); CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina)”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”20 min”,”value”:”20 min. (470w)”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”234″,”value”:”234″},{“name”:”Undervoltage Correction”,”normalizedValue”:”Input voltages between 191 and 215 are boosted by 10%”,”value”:”Input voltages between 191 and 215 are boosted by 10%”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 95%, non-condensing”,”value”:”0 to 95%, non-condensing”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”325″,”value”:”325″},{“name”:”Alarm Cancel Operation”,”normalizedValue”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”,”value”:”Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door”},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”230 V AC”,”value”:”230V AC”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Audible Alarm”,”normalizedValue”:”Audible alarm indicates power-failure and low-battery conditions”,”value”:”Audible alarm indicates power-failure and low-battery conditions”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”-15%”,”value”:”-15%, +8%”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Storage Temperature Range”,”normalizedValue”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”,”value”:”+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius”},{“name”:”UPS Housing Material”,”normalizedValue”:”Polycarbonate”,”value”:”Polycarbonate”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”12.8 x 7.5 x 9.2″,”value”:”12.8 x 7.5 x 9.2″},{“name”:”Output Receptacles”,”normalizedValue”:”C13″,”value”:”(6) C13″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”1,500″,”value”:”1500″},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Sine wave”,”value”:”Sine wave”},{“name”:”Communications Cable”,”normalizedValue”:”2 DB9 cables included”,”value”:”2 DB9 cables included”},{“name”:”Nominal Voltage Details”,”normalizedValue”:”230V nominal output in battery mode”,”value”:”230V nominal output in battery mode”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Input voltages between 243 and 277 are reduced by 12%”,”value”:”Input voltages between 243 and 277 are reduced by 12%”},{“name”:”Communications Interface”,”normalizedValue”:”DB9 Serial; Contact closure”,”value”:”DB9 Serial; Contact closure”},{“name”:”Severe Undervoltage Correction”,”normalizedValue”:”Input voltages between 165 and 190 are boosted by 22%”,”value”:”Input voltages between 165 and 190 are boosted by 22%”},{“name”:”LED Indicators”,”normalizedValue”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”,”value”:”5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status”},{“name”:”Frequency Compatibility”,”normalizedValue”:”50 / 60 Hz”,”value”:”50 / 60 Hz”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Supports detailed monitoring of UPS and site power conditions; contact closure communications via 2nd DB9 port (2 total)”,”value”:”Supports detailed monitoring of UPS and site power conditions; contact closure communications via 2nd DB9 port (2 total)”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”1.5″,”value”:”1.5″},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 166 to 277″,”value”:”Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 166 to 277″},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”165″,”value”:”165″},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”0.94″,”value”:”0.94″},{“name”:”Included Output Power Cables”,”normalizedValue”:”Includes 2 C13 to C14 output power cables”,”value”:”Includes 2 C13 to C14 output power cables”},{“name”:”Installation Form Factors Supported with Optional Accessories”,”normalizedValue”:”Wallmount (UPSWM – tower mounting kit)”,”value”:”Wallmount (UPSWM – tower mounting kit)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”7 min”,”value”:”7 min. (940w)”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”191″,”value”:”191″},{“name”:”Switches”,”normalizedValue”:”2 Switches control off/on power status and alarm-cancel/self-test operation”,”value”:”2 Switches control off/on power status and alarm-cancel/self-test operation”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”220 V, 230 V, 240 V”,”value”:”220V; 230V; 240V”},{“name”:”Battery Replacement Description”,”normalizedValue”:”Hot-swappable, user replaceable batteries”,”value”:”Hot-swappable, user replaceable batteries”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”inlet”,”value”:”C14 inlet”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”6.5 A”,”value”:”6.5A”},{“name”:”UPS Certification Details”,”normalizedValue”:”EMI approvals 62040″,”value”:”EMI approvals 62040″},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Automatic frequency selection”,”value”:”Automatic frequency selection”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”480″,”value”:”480″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”36″,”value”:”36″},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 5%”,”value”:”+/- 5%”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Hot swappable batteries”,”value”:”Hot swappable batteries”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC53″,”value”:”RBC53″},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”,”value”:”Less than 4 hours from 10% to 90% (typical, full load discharge)”},{“name”:”Product Type”,”normalizedValue”:”Line-interactive UPS”,”value”:”Line-interactive UPS”},{“name”:”Plug/Connector Type”,”normalizedValue”:”IEC 320-C14″,”value”:”IEC 320-C14″},{“name”:”Additional Information”,”normalizedValue”:”Ideal for the protection of fileservers, network accessories and telecommunications equipment. Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems. Ideal for sensitive electronic applications in areas where brownouts and overvoltages are common, Switches: Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions, Form factors supported: Tower, wall mountable with optional UPSWM accessory, Low voltage transfer to battery power: 165V (resets to line power as line voltage increases to 168V or higher), High voltage transfer to battery power: 277V (resets to line power as line voltage decreases to 271 or lower)”,”value”:”Ideal for the protection of fileservers, network accessories and telecommunications equipment. Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems. Ideal for sensitive electronic applications in areas where brownouts and overvoltages are common, Switches: Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions, Form factors supported: Tower, wall mountable with optional UPSWM accessory, Low voltage transfer to battery power: 165V (resets to line power as line voltage increases to 168V or higher), High voltage transfer to battery power: 277V (resets to line power as line voltage decreases to 271 or lower)”},{“name”:”Load Capacity”,”normalizedValue”:”1500 VA/940 W”,”value”:”1500 VA/940 W”},{“name”:”Typical Battery Recharge Time”,”normalizedValue”:”4 hr”,”value”:”4 Hour”},{“name”:”Package Contents”,”normalizedValue”:”SmartPro 1500VA Tower UPS, SMARTINT1500 UPS System, 2 IEC-320 C13 to C14 power cables, 2 DB9 monitoring cables, PowerAlert unattended shutdown and UPS/Power monitoring software, Instruction manual with warranty information”,”value”:”SmartPro 1500VA Tower UPS, SMARTINT1500 UPS System, 2 IEC-320 C13 to C14 power cables, 2 DB9 monitoring cables, PowerAlert unattended shutdown and UPS/Power monitoring software, Instruction manual with warranty information”},{“name”:”Receptacle Detail”,”normalizedValue”:”6 x IEC 60320 C13″,”value”:”6 x IEC 60320 C13″},{“name”:”Certifications u0026 Standards”,”normalizedValue”:”CE EN62040 listed, UL, cUL, GOST, IRAM, SASO”,”value”:”CE EN62040 listed, UL, cUL, GOST, IRAM, SASO”},{“name”:”Backup/Run Time (Half Load)”,”normalizedValue”:”20 min”,”value”:”20 Minute”},{“name”:”Serial Port”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Line”,”normalizedValue”:”SmartPro”,”value”:”SmartPro”},{“name”:”Hot Swappable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Name”,”normalizedValue”:”SmartPro 1500VA Tower UPS”,”value”:”SmartPro 1500VA Tower UPS”},{“name”:”Software Included”,”normalizedValue”:”PowerAlert unattended shutdown and UPS/Power monitoring software”,”value”:”PowerAlert unattended shutdown and UPS/Power monitoring software”},{“name”:”Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “UPS System, 1.5kVA, 6 Outlets, Tower, Out: 220/230/240V AC , In:230V AC, Tripp Lite, Mfr#: SMARTINT1500”