Description
[{“name”:”Item”,”normalizedValue”:”True RMS Clamp Meter”,”rank”:1,”value”:”True RMS Clamp Meter”},{“name”:”Digital/Analog”,”normalizedValue”:”Digital”,”rank”:3,”value”:”Digital”},{“name”:”Safety Rating”,”normalizedValue”:”CAT III 600V”,”rank”:11,”value”:”CAT III 600V”},{“name”:”Jaw Opening”,”normalizedValue”:”1.2 in”,”rank”:14,”value”:”1.2 in”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Data Logging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Memory”,”normalizedValue”:”Data Hold”,”value”:”Data Hold”},{“name”:”Includes”,”normalizedValue”:”(3) AAA Batteries, Carrying Case, Test Leads, Type K Thermocouple Bead Probe”,”value”:”(3) AAA Batteries, Carrying Case, Test Leads, Type K Thermocouple Bead Probe”},{“name”:”Non-Contact Voltage Detector”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Frequency Counter”,”normalizedValue”:”50 to 60 Hz”,”value”:”50 to 60 Hz”},{“name”:”Peak Hold”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Thermometer Type”,”normalizedValue”:”Type K Thermocouple”,”value”:”Type K Thermocouple”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Standards”,”normalizedValue”:”CE, ETL, RoHS Compliant”,”value”:”CE, ETL, RoHS Compliant”},{“name”:”Special Features”,”normalizedValue”:”Built-In Flashlight, Low Pass Filter (LPF), Peak Voltage Measurement with Min/Max, Relative Mode for Making Comparisons to a Stored Reference Value and DC Zero, True RMS”,”value”:”Built-In Flashlight, Low Pass Filter (LPF), Peak Voltage Measurement with Min/Max, Relative Mode for Making Comparisons to a Stored Reference Value and DC Zero, True RMS”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Minimum DC Current Measurement”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Minimum DC Voltage Measurement”,”normalizedValue”:”4 V”,”value”:”4 V”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-1.0% +/- 5 digits”,”value”:”+/-1.0% +/- 5 digits”},{“name”:”Jaw Style”,”normalizedValue”:”Clamp On”,”value”:”Clamp On”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”+/-2.5% +/-8 digits”,”value”:”+/-2.5% +/-8 digits”},{“name”:”True RMS Bandwidth”,”normalizedValue”:”2 kHz”,”value”:”2 kHz”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Overall Width”,”normalizedValue”:”1.6 in”,”value”:”1.6 in”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”10 Hz”,”value”:”10 Hz”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”100 kHz”,”value”:”100 kHz”},{“name”:”Capacitance Measurement Resolution”,”normalizedValue”:”0.01 mF”,”value”:”0.01 mF”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Battery Voltage”,”normalizedValue”:”1.5V”,”value”:”1.5V”},{“name”:”Instrument Counts”,”normalizedValue”:”4,000″,”value”:”4,000″},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”400 A”,”value”:”400 A”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-1.2% +/-3 digits”,”value”:”+/-1.2% +/-3 digits”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:”1 mV”,”value”:”1 mV”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-4.5% +/-20 digits”,”value”:”+/-4.5% +/-20 digits”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Overall Height”,”normalizedValue”:”8.8 in”,”value”:”8.8 in”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”+/-2.5%”,”value”:”+/-2.5%”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”400 A”,”value”:”400 A”},{“name”:”Inrush Current Measurable”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Display Type”,”normalizedValue”:”Backlit LCD”,”value”:”Backlit LCD”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”100 mF”,”value”:”100 mF”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, DC Current, DC Voltage”,”value”:”AC Current, AC Voltage, DC Current, DC Voltage”},{“name”:”Minimum Capacitance Measurement”,”normalizedValue”:”99.99 nF”,”value”:”99.99 nF”},{“name”:”AC Response Calculation”,”normalizedValue”:”TRMS”,”value”:”TRMS”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-1.2% +/- 3 digits”,”value”:”+/-1.2% +/- 3 digits”},{“name”:”Minimum Resistance Measurement”,”normalizedValue”:”400 ohm”,”value”:”400 ohm”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”40 megaohm”,”value”:”40 megaohm”},{“name”:”Battery Size”,”normalizedValue”:”AAA”,”value”:”AAA”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:”10 kiloohm”,”value”:”10 kiloohm”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-2.5% +/-8 digits”,”value”:”+/-2.5% +/-8 digits”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”IP Rating”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”4 V”,”value”:”4 V”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:”1 mV”,”value”:”1 mV”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.