Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Timer”,”rank”:1,”value”:”Timer”},{“name”:”Contact Form”,”normalizedValue”:”DPDT”,”rank”:4,”value”:”DPDT”},{“name”:”Standards”,”normalizedValue”:”Conforms to EN 61812-1 and IEC 60664-1 (VDE 0110) 4kV/2, Output Category According to EN 60947-5-1 for Timers with Contact Outputs, Output Category According to EN60947-5-2 for Timers with Transistor Outputs, UL508, CSA C22.2 No. 14, NK, Lloyd’s, CCC: GB/T 14048.5″,”rank”:5,”value”:”Conforms to EN 61812-1 and IEC 60664-1 (VDE 0110) 4kV/2, Output Category According to EN 60947-5-1 for Timers with Contact Outputs, Output Category According to EN60947-5-2 for Timers with Transistor Outputs, UL508, CSA C22.2 No. 14, NK, Lloyd’s, CCC: GB/T 14048.5″},{“name”:”Contact Material”,”normalizedValue”:”Silver Alloy”,”value”:”Silver Alloy”},{“name”:”Series”,”normalizedValue”:”H3CR-H”,”value”:”H3CR-H”},{“name”:”Electrical Connection”,”normalizedValue”:”Socket”,”value”:”Socket”},{“name”:”Input Voltage”,”normalizedValue”:”200/220/240V AC”,”value”:”200/220/240V AC”},{“name”:”Adjustment Interface”,”normalizedValue”:”Analog”,”value”:”Analog”},{“name”:”Power Consumption”,”normalizedValue”:”0.35 VA”,”value”:”0.35 VA”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”55 deg C”,”value”:”55 Degrees C”},{“name”:”Compatible with Manufacturer Model Number”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”Contact Rating (AC)”,”normalizedValue”:”5 A @ 250V (Resistive Load)”,”value”:”5 A @ 250V (Resistive Load)”},{“name”:”Minimum Time Setting”,”normalizedValue”:”0.05 sec”,”value”:”0.05 sec”},{“name”:”Body Height”,”normalizedValue”:”1.88 in”,”value”:”1.88 in”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Delay Function”,”normalizedValue”:”Power OFF Delay”,”value”:”Power OFF Delay”},{“name”:”Reset Method”,”normalizedValue”:”Instantaneous Time-Limit Reset”,”value”:”Instantaneous Time-Limit Reset”},{“name”:”Relay Operation”,”normalizedValue”:”Solid State”,”value”:”Solid State”},{“name”:”Overall Depth”,”normalizedValue”:”3.66 in”,”value”:”3.66 in”},{“name”:”Contact Rating (DC)”,”normalizedValue”:”10 mA @ 5 V”,”value”:”10.00 mA @ 5V”},{“name”:”Number of Pins”,”normalizedValue”:”8″,”value”:”8″},{“name”:”Operating Time Accuracy”,”normalizedValue”:”+/-0.2% +/-10 ms in a range of 0.6 s and 1.2 s, +/-0.2% FS max”,”value”:”+/-0.2% +/-10 ms in a range of 0.6 s and 1.2 s, +/-0.2% FS max”},{“name”:”Coil Voltage”,”normalizedValue”:”200/220/240V AC”,”value”:”200/220/240V AC”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”125V DC”,”value”:”125V DC”},{“name”:”Base Shape”,”normalizedValue”:”Octal”,”value”:”Octal”},{“name”:”Body Width”,”normalizedValue”:”1.88 in”,”value”:”1.88 in”},{“name”:”Current Rating”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”1,000,000″,”value”:”1,000,000″},{“name”:”Electrical Operating Durability”,”normalizedValue”:”100,000″,”value”:”100,000″},{“name”:”Body Depth”,”normalizedValue”:”3.12 in”,”value”:”3.12 in”},{“name”:”IP Rating”,”normalizedValue”:”IP40″,”value”:”IP40″},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail, Surface”,”value”:”DIN Rail, Surface”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-10 deg C”,”value”:”-10 Degrees C”},{“name”:”Number of Delay Functions”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Maximum Time Setting”,”normalizedValue”:”0.6 sec”,”value”:”0.6 sec”},{“name”:”Weight”,”normalizedValue”:”120 g”,”value”:”120 g”},{“name”:”Compatible Manufacturer Part Number”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”Compatible Manufacturer Model Number”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”For Use With Mfr. Model Number”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”Compatible with Manufacturer Model No.”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”Compatible with Mfr. Model No.”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”For Use with Mfr Model Number”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”Compatible Pump Manufacturer Part Number”,”normalizedValue”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″,”value”:”P2CF-08, P2CF-08-E, P3G-08, PF085A, PL08, PL08-Q, PLE08-0″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.