Description
[{“name”:”Phase – Electrical”,”normalizedValue”:”Three”,”rank”:1,”value”:”Three”},{“name”:”Input Voltage – Transformer”,”normalizedValue”:”480V AC Delta”,”rank”:2,”value”:”480V AC Delta”},{“name”:”Output Voltage – Transformer”,”normalizedValue”:”120V AC, 208V AC Wye”,”rank”:3,”value”:”120V AC, 208V AC Wye”},{“name”:”Item – Transformer”,”normalizedValue”:”Three Phase Transformer”,”rank”:4,”value”:”Three Phase Transformer”},{“name”:”VA Rating – Transformer”,”normalizedValue”:”225 kVA”,”rank”:5,”value”:”225 kVA”},{“name”:”Mounting – Transformer”,”normalizedValue”:”Floor”,”rank”:6,”value”:”Floor”},{“name”:”Outdoor Rated – Transformer”,”normalizedValue”:”No”,”rank”:7,”value”:”No”},{“name”:”Temp. Rise”,”normalizedValue”:”150 deg C”,”rank”:8,”value”:”150 Degrees C”},{“name”:”Winding Material – Transformer”,”normalizedValue”:”Aluminum”,”rank”:9,”value”:”Aluminum”},{“name”:”Hz – Electrical”,”normalizedValue”:”60 Hz”,”rank”:10,”value”:”60 Hz”},{“name”:”VA Rating”,”normalizedValue”:”225 kVA”,”value”:”225kVA”},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Height”,”normalizedValue”:”57-1/2 in”,”value”:”57.5 in”},{“name”:”Voltage Function – Transformer”,”normalizedValue”:”Step Down”,”value”:”Step Down”},{“name”:”Input Voltage”,”normalizedValue”:”480VAC”,”value”:”480VAC”},{“name”:”Depth”,”normalizedValue”:”32-3/4 in”,”value”:”32.75 in”},{“name”:”Mounting”,”normalizedValue”:”Floor”,”value”:”Floor”},{“name”:”Enclosure Rating”,”normalizedValue”:”NEMA 1″,”value”:”NEMA 1 (Convertible to NEMA 3R by Adding Weather Shield)”},{“name”:”Output Voltage”,”normalizedValue”:”208VAC Wye/120VAC”,”value”:”208VAC Wye/120VAC”},{“name”:”Enclosure Type”,”normalizedValue”:”Indoor”,”value”:”Indoor”},{“name”:”Knockout Size – Transformer”,”normalizedValue”:”No Knockout”,”value”:”No Knockout”},{“name”:”Width”,”normalizedValue”:”40.07 in”,”value”:”40.07 in”},{“name”:”Item”,”normalizedValue”:”Three Phase Transformer”,”value”:”Three Phase Transformer”},{“name”:”Standards”,”normalizedValue”:”NEMA ST-20, UL Listed”,”value”:”NEMA ST-20, UL Listed”},{“name”:”Mounting – Transformer”,”normalizedValue”:”Floor”,”value”:”Floor”},{“name”:”Phase”,”normalizedValue”:”3 phase”,”value”:”3 phase”},{“name”:”Material”,”normalizedValue”:”Aluminium”,”value”:”aluminium”},{“name”:”Continuous Thermal Current Rating Factor”,”normalizedValue”:”1451.2286916602 16.6 % || 1984.8003496249999 25 % || 4847.8007465 50 % || 9619.468074625 75 % || 16299.802333999998 1.0 %”,”value”:”1451.2286916602 16.6 % || 1984.8003496249999 25 % || 4847.8007465 50 % || 9619.468074625 75 % || 16299.802333999998 1.0 %”},{“name”:”Degree Of Protection”,”normalizedValue”:”UL type 1 || UL type 2, with 7400DS25J || UL type 3R, with 7400WS25J”,”value”:”UL type 1 || UL type 2, with 7400DS25J || UL type 3R, with 7400WS25J”},{“name”:”Temperature Rise”,”normalizedValue”:”220°C insulated || 150°C”,”value”:”220°C insulated || 150°C”},{“name”:”Network Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Percentage Reactance”,”normalizedValue”:”0.0004″,”value”:”0.000388″},{“name”:”[Ipk] Rated Peak Withstand Current”,”normalizedValue”:”14.3 kA”,”value”:”14.3 kA”},{“name”:”Efficiency”,”normalizedValue”:”99.06 % at 35 % load factor , 75.0°C”,”value”:”99.06 % at 35 % load factor , 75.0°C”},{“name”:”Transformer Type”,”normalizedValue”:”energy efficient”,”value”:”energy efficient”},{“name”:”Type Of Cooling”,”normalizedValue”:”natural convection”,”value”:”natural convection”},{“name”:”Rated Operational Power In Va”,”normalizedValue”:”225 kVA”,”value”:”225 kVA”},{“name”:”Mounting Support”,”normalizedValue”:”floor || floor, with 7400FMB”,”value”:”floor || floor, with 7400FMB”},{“name”:”Product Or Component Type”,”normalizedValue”:”transformer”,”value”:”transformer”},{“name”:”Secondary Voltage”,”normalizedValue”:”208Y/120 V”,”value”:”208Y/120 V”},{“name”:”Tap Loss”,”normalizedValue”:”302.0 no load (core loss) || 4475.0 load loss (coil loss)”,”value”:”302.0 no load (core loss) || 4475.0 load loss (coil loss)”},{“name”:”Device Short Name”,”normalizedValue”:”DOE 2016″,”value”:”DOE 2016″},{“name”:”Noise Level”,”normalizedValue”:”6 dB NEMA ST-20 || 49 dB”,”value”:”6 dB NEMA ST-20 || 49 dB”},{“name”:”Average Ambient Air Temperature For Operation”,”normalizedValue”:”30°C”,”value”:”30°C”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”40-40°C”,”value”:”40-40°C”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”10 kV”,”value”:”10 kV”},{“name”:”Primary Voltage”,”normalizedValue”:”480 V delta”,”value”:”480 V delta”},{“name”:”Number Of Tap-Offs”,”normalizedValue”:”2 2.5 % FCAN || 4 2.5 % FCBN”,”value”:”2 2.5 % FCAN || 4 2.5 % FCBN”},{“name”:”Device Application”,”normalizedValue”:”low voltage electrical distribution”,”value”:”low voltage electrical distribution”},{“name”:”Percentage Impedance Voltage”,”normalizedValue”:”0.044″,”value”:”0.044″},{“name”:”X/R Ratio”,”normalizedValue”:”1.95″,”value”:”1.95″},{“name”:”Electrical Connection”,”normalizedValue”:”4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec – XO 11.1 mm”,”value”:”4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec – XO 11.1 mm”},{“name”:”Sound Level”,”normalizedValue”:”6 dB NEMA ST-20, 49 dB”,”value”:”6 dB NEMA ST-20, 49 dB”},{“name”:”Transformer Losses”,”normalizedValue”:”302.0 no load (core loss), 4475.0 load loss (coil loss)”,”value”:”302.0 no load (core loss), 4475.0 load loss (coil loss)”},{“name”:”Transformer Btu/Hr”,”normalizedValue”:”1451.2286916602 16.6%, 1984.8003496249999 25%, 4847.8007465 50%, 9619.468074625 75%, 16299.802333999998 1.0%”,”value”:”1451.2286916602 16.6%, 1984.8003496249999 25%, 4847.8007465 50%, 9619.468074625 75%, 16299.802333999998 1.0%”},{“name”:”Box Number”,”normalizedValue”:”25J”,”value”:”25J”},{“name”:”DOE Efficiency”,”normalizedValue”:”99.06% at 35% load factor, 167°F”,”value”:”99.06% at 35% load factor , 167°F (75.0°C)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.